# CertainTeed Apollo II - 73x — CEC Solar Module Specifications

Manufacturer: [**CertainTeed**](https://epri-peac.com/solar-equipment/brands/certainteed/) Registry: **CEC Verified Engineering Specification**

CertainTeed Apollo II - 73x is a 73.0 W STC (62.4 W PTC) Mono-c-Si solar module ranking #21,623 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 13.77% efficiency, 9.77 V Voc at 25 C, and 10.7 V cold Voc at -10 C (56 panels max per 600 V string).

- **STC Wattage** : 73.0 W

- **PTC Wattage** : 62.4 W

- **Voc @ 25C** : 9.77 V

- **Efficiency** : 13.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does CertainTeed Apollo II - 73x Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CertainTeed Apollo II - 73x (Mono-c-Si) residential solar systems.

Homeowners evaluating CertainTeed Apollo II - 73x need 83 panels for 6 kW or 110 panels (628 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 110 panels (628 sq ft). Under NEC 690.7(A), beta_Voc (-0.273%/C) pushes open-circuit voltage to 10.7 V at 14 F and 10.97 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does CertainTeed Apollo II - 73x Fall Across Listed CEC Models?

Comparison of CertainTeed Apollo II - 73x (73.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define CertainTeed Apollo II - 73x?

Relative ranking of CertainTeed Apollo II - 73x across nameplate watts, 85.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for CertainTeed Apollo II - 73x?

Summary of CertainTeed Apollo II - 73x output rank, 8 kW array size (110 panels), efficiency rating, and 600 V string limit.

Rank #21,623 / 21,677

### 73.0 W STC · Higher Than 0.2%

73.0 W STC (-312.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,055

### 13.77% Aperture Efficiency

Power density 137.7 W/m2 (6.14 percentage points below 19.91% CEC median). PTC/STC ratio: 85.5% (rank #21,659).

NEC 690.7 Limit

### 56 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.7 V at -10 C (599.2 V string) and 10.97 V at -20 C (54 max).

 8 kW Reference Array

### 110 Panels = 8,030 W STC

Occupies 58.3 m2 (628 sq ft) producing 6,864 W PTC; NEC 690.8 OCPD floor is 14.87 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.77 * (1 + (-0.273/100) * (-10 - 25)) = 10.7 V | OCPD = 1.56 * 9.53 = 14.87 A

Inputs from CEC Modules.csv for CertainTeed Apollo II - 73x: Voc=9.77 V, beta_Voc=-0.273%/C, Isc=9.53 A, STC=73.0 W, Area=0.53 m2.

**Result:** 56 panels max on 600 V (599.2 V); 110 panels for 8 kW (628 sq ft).

## What Are the Published CEC Specifications for CertainTeed Apollo II - 73x?

Complete CEC test sheet for CertainTeed Apollo II - 73x including Isc (9.53 A), Voc (9.77 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo II - 73x.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 73.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 62.4 W (85.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.77 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 7.94 V / 9.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.273 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.77% (0.53 m2) | Array roof footprint density |
| **Cell Count & Technology** | 14 cells (Mono-c-Si) | Monofacial backsheet |

## How Many CertainTeed Apollo II - 73x Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CertainTeed Apollo II - 73x.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 83 | 6.06 kW | 474 sq ft | $1,517 | $2,565 |
| **8 kW Class** | 110 | 8.03 kW | 628 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 137 | 10.0 kW | 782 sq ft | $2,503 | $4,232 |

## How Many CertainTeed Apollo II - 73x Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for CertainTeed Apollo II - 73x (9.77 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=9.77V and beta_Voc=-0.273%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 10.97 V | 54 panels | 592.4 V | 91 panels |
| **-10 C (14 F)** | 10.7 V | 56 panels | 599.2 V | 93 panels |
| **0 C (32 F)** | 10.44 V | 57 panels | 595.1 V | 95 panels |
| **25 C (77 F STC)** | 9.77 V | 61 panels | 596.0 V | 102 panels |

## Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 73x?

Four comparable CEC modules such as Merlin Solar Technologies Inc Solstice Shingle 72W-01 (72.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc Solstice Shingle 72W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-72w-01/) Merlin Solar Technologies Inc | 72.0 W | -1.0 W | 9.65 V | 13.58% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 70W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-70w-01/) Merlin Solar Technologies Inc | 70.0 W | -3.0 W | 9.51 V | 13.21% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 68W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-68w-01/) Merlin Solar Technologies Inc | 68.0 W | -5.0 W | 9.37 V | 12.83% | 89.4% |
| [**LUMA Resources LRSS**](https://epri-peac.com/solar-equipment/modules/luma-resources/luma-resources-lrss/) LUMA Resources | 80.0 W | +7.0 W | 10.43 V | 16.0% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 73x?

Evaluate CertainTeed Apollo II - 73x (73.0 W STC, 9.77 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 73x reaches 10.97 V per panel—exceeding 54 panels in series voids 600 V inverter warranties.
- Footprint constraint: 110 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 110 panels (628 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 73x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### CertainTeed Apollo II - 73x 8 kW Residential Fit

Needs 110 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 56 panels (-10 C) or 54 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 62.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo II - 73x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is CertainTeed Apollo II - 73x PTC wattage (62.4 W) lower than STC (73.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 62.4 W PTC (85.5% retention) across CertainTeed Apollo II - 73x's 0.53 m2 aperture.

### Who should skip CertainTeed Apollo II - 73x on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 110 CertainTeed Apollo II - 73x panels (628 sq ft) leave unusable roof gaps vs. Merlin Solar Technologies Inc Solstice Shingle 72W-01.

### What is the 1,000 V commercial string limit for CertainTeed Apollo II - 73x?

On 1,000 V commercial inverters at -10 C (10.7 V cold Voc), CertainTeed Apollo II - 73x fits up to 93 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting CertainTeed Apollo II - 73x.

## Related Pages

Compare CertainTeed equipment, Merlin Solar Technologies Inc Solstice Shingle 72W-01 specs, utility payback rates, and NEC string calculators alongside CertainTeed Apollo II - 73x.

[All CertainTeed Certified Solar Models](https://epri-peac.com/solar-equipment/brands/certainteed/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From CertainTeed

- [All CertainTeed Specs](https://epri-peac.com/solar-equipment/brands/certainteed/)
- [CertainTeed CTM10455HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10455hc11-06/)
- [CertainTeed CTTC455HC12-08](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc455hc12-08/)
- [CertainTeed CTM10450HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10450hc11-06/)
- [CertainTeed CTM10445HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10445hc11-06/)
- [CertainTeed CTM10440HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/)