title: "CertainTeed Apollo II - 72x Specs (72.0W, 9.71V Voc)"
url: https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-72x/
description: "CEC datasheet for CertainTeed Apollo II - 72x: 72.0W STC, 9.71V Voc, 112-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# CertainTeed Apollo II - 72x — CEC Solar Module Specifications

Manufacturer: [**CertainTeed**](https://epri-peac.com/solar-equipment/brands/certainteed/) Registry: **CEC Verified Engineering Specification**

CertainTeed Apollo II - 72x is a 72.0 W STC (61.5 W PTC) Mono-c-Si solar module ranking #21,628 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 13.58% efficiency, 9.71 V Voc at 25 C, and 10.64 V cold Voc at -10 C (56 panels max per 600 V string).

- **STC Wattage** : 72.0 W

- **PTC Wattage** : 61.5 W

- **Voc @ 25C** : 9.71 V

- **Efficiency** : 13.58%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does CertainTeed Apollo II - 72x Compare Against Peer CEC Listings?

How CertainTeed CertainTeed Apollo II - 72x handles rooftop heat (61.5 W PTC), 8 kW sizing, and cold winter string voltage.

CertainTeed builds the CertainTeed Apollo II - 72x (Mono-c-Si) as a compact residential or specialty off-grid module delivering 135.8 W/m2 (6.33 percentage points below 19.91% CEC median). Compared against Merlin Solar Technologies Inc Solstice Shingle 72W-01 (72.0 W), this model holds typical 85.4% PTC-to-STC thermal output (61.5 W real-world rating). Lower 9.71 V string voltage fits 56 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.8 A overcurrent floor served by a 15 A breaker.

## Where Does CertainTeed Apollo II - 72x Fall Across Listed CEC Models?

Where CertainTeed Apollo II - 72x (72.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define CertainTeed Apollo II - 72x?

Percentile placement of CertainTeed Apollo II - 72x across power density (135.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for CertainTeed Apollo II - 72x?

Four critical engineering numbers homeowners and solar installers check first when reviewing CertainTeed Apollo II - 72x specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #21,628 / 21,677

### 72.0 W STC · Higher Than 0.2%

72.0 W STC (-313.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,170

### 13.58% Aperture Efficiency

Power density 135.8 W/m2 (6.33 percentage points below 19.91% CEC median). PTC/STC ratio: 85.4% (rank #21,662).

NEC 690.7 Limit

### 56 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.64 V at -10 C (595.8 V string) and 10.9 V at -20 C (55 max).

 8 kW Reference Array

### 112 Panels = 8,064 W STC

Occupies 59.4 m2 (639 sq ft) producing 6,888 W PTC; NEC 690.8 OCPD floor is 14.8 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.71 * (1 + (-0.273/100) * (-10 - 25)) = 10.64 V | OCPD = 1.56 * 9.49 = 14.8 A

Inputs from CEC Modules.csv for CertainTeed Apollo II - 72x: Voc=9.71 V, beta_Voc=-0.273%/C, Isc=9.49 A, STC=72.0 W, Area=0.53 m2.

**Result:** 56 panels max on 600 V (595.8 V); 112 panels for 8 kW (639 sq ft).

## What Are the Published CEC Specifications for CertainTeed Apollo II - 72x?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CertainTeed Apollo II - 72x.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo II - 72x.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 72.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 61.5 W (85.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.71 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.49 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 7.89 V / 9.14 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.273 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.58% (0.53 m2) | Array roof footprint density |
| **Cell Count & Technology** | 14 cells (Mono-c-Si) | Monofacial backsheet |

## How Many CertainTeed Apollo II - 72x Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CertainTeed Apollo II - 72x (72.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 84 | 6.05 kW | 479 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 112 | 8.06 kW | 639 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 139 | 10.01 kW | 793 sq ft | $2,505 | $4,236 |

## How Many CertainTeed Apollo II - 72x Modules Fit in a Cold-Weather String?

Maximum series module counts for CertainTeed Apollo II - 72x from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=9.71V and beta_Voc=-0.273%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 10.9 V | 55 panels | 599.5 V | 91 panels |
| **-10 C (14 F)** | 10.64 V | 56 panels | 595.8 V | 93 panels |
| **0 C (32 F)** | 10.37 V | 57 panels | 591.1 V | 96 panels |
| **25 C (77 F STC)** | 9.71 V | 61 panels | 592.3 V | 102 panels |

## Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 72x?

Alternative CEC solar modules from competing brands near CertainTeed Apollo II - 72x (72.0 W), including Merlin Solar Technologies Inc Solstice Shingle 72W-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc Solstice Shingle 72W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-72w-01/) Merlin Solar Technologies Inc | 72.0 W | Tie (0 W) | 9.65 V | 13.58% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 70W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-70w-01/) Merlin Solar Technologies Inc | 70.0 W | -2.0 W | 9.51 V | 13.21% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 68W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-68w-01/) Merlin Solar Technologies Inc | 68.0 W | -4.0 W | 9.37 V | 12.83% | 89.4% |
| [**LUMA Resources LRSS**](https://epri-peac.com/solar-equipment/modules/luma-resources/luma-resources-lrss/) LUMA Resources | 80.0 W | +8.0 W | 10.43 V | 16.0% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 72x?

Evaluate CertainTeed Apollo II - 72x (72.0 W STC, 9.71 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 72x reaches 10.9 V per panel—exceeding 55 panels in series voids 600 V inverter warranties.
- Footprint constraint: 112 panels for an 8 kW build require 639 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 112 panels (639 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 72x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### CertainTeed Apollo II - 72x 8 kW Residential Fit

Needs 112 modules (639 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 56 panels (-10 C) or 55 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 61.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo II - 72x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for CertainTeed Apollo II - 72x?

Multiplying CertainTeed Apollo II - 72x's 9.49 A short-circuit current by 1.56 equals 14.8 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can CertainTeed Apollo II - 72x pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 10.64 V cold Voc at 14 F and handles 9.49 A Isc; string inverters cap CertainTeed Apollo II - 72x at 56 panels on 600 V.

### Is CertainTeed Apollo II - 72x eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed Apollo II - 72x rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare CertainTeed equipment, Merlin Solar Technologies Inc Solstice Shingle 72W-01 specs, utility payback rates, and NEC string calculators alongside CertainTeed Apollo II - 72x.

[All CertainTeed Certified Solar Models](https://epri-peac.com/solar-equipment/brands/certainteed/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From CertainTeed

- [All CertainTeed Specs](https://epri-peac.com/solar-equipment/brands/certainteed/)
- [CertainTeed CTM10455HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10455hc11-06/)
- [CertainTeed CTTC455HC12-08](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc455hc12-08/)
- [CertainTeed CTM10450HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10450hc11-06/)
- [CertainTeed CTM10445HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10445hc11-06/)
- [CertainTeed CTM10440HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/)