---
title: "CertainTeed Apollo II - 71x Specs (71.0W, 9.64V Voc)"
url: https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-71x/
description: "CEC datasheet for CertainTeed Apollo II - 71x: 71.0W STC, 9.64V Voc, 113-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# CertainTeed Apollo II - 71x — CEC Solar Module Specifications

Manufacturer: [**CertainTeed**](https://epri-peac.com/solar-equipment/brands/certainteed/) Registry: **CEC Verified Engineering Specification**

CertainTeed Apollo II - 71x is a 71.0 W STC (60.6 W PTC) Mono-c-Si solar module ranking #21,635 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 13.4% efficiency, 9.64 V Voc at 25 C, and 10.56 V cold Voc at -10 C (56 panels max per 600 V string).

- **STC Wattage** : 71.0 W

- **PTC Wattage** : 60.6 W

- **Voc @ 25C** : 9.64 V

- **Efficiency** : 13.4%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does CertainTeed Apollo II - 71x Compare Against Peer CEC Listings?

Engineering position of CertainTeed Apollo II - 71x (71.0 W STC) vs. Merlin Solar Technologies Inc Solstice Shingle 72W-01 across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,635 across 21,677 CEC solar panels (below all-CEC median; higher than 0.2% of peers), CertainTeed Apollo II - 71x operates as a compact residential or specialty off-grid module sitting 339.0 W below the 410.0 W Mono-c-Si median. Lower 9.64 V string voltage fits 56 panels in series at 14 F and pairs easily with microinverters. With typical 85.4% PTC-to-STC thermal output (60.6 W real-world rating), 113 panels occupy 645 sq ft and offset roughly $2,007/yr at average US rates (or $3,394/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does CertainTeed Apollo II - 71x Fall Across Listed CEC Models?

Plots CertainTeed Apollo II - 71x at 71.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define CertainTeed Apollo II - 71x?

Benchmarks CertainTeed Apollo II - 71x on STC wattage, thermal PTC/STC retention, and 13.4 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for CertainTeed Apollo II - 71x?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for CertainTeed Apollo II - 71x by CertainTeed.

Rank #21,635 / 21,677

### 71.0 W STC · Higher Than 0.2%

71.0 W STC (-314.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,253

### 13.4% Aperture Efficiency

Power density 134.0 W/m2 (6.51 percentage points below 19.91% CEC median). PTC/STC ratio: 85.4% (rank #21,662).

NEC 690.7 Limit

### 56 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.56 V at -10 C (591.4 V string) and 10.82 V at -20 C (55 max).

 8 kW Reference Array

### 113 Panels = 8,023 W STC

Occupies 59.9 m2 (645 sq ft) producing 6,848 W PTC; NEC 690.8 OCPD floor is 14.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.64 * (1 + (-0.273/100) * (-10 - 25)) = 10.56 V | OCPD = 1.56 * 9.46 = 14.76 A

Inputs from CEC Modules.csv for CertainTeed Apollo II - 71x: Voc=9.64 V, beta_Voc=-0.273%/C, Isc=9.46 A, STC=71.0 W, Area=0.53 m2.

**Result:** 56 panels max on 600 V (591.4 V); 113 panels for 8 kW (645 sq ft).

## What Are the Published CEC Specifications for CertainTeed Apollo II - 71x?

Laboratory test ratings recorded for CertainTeed Apollo II - 71x (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo II - 71x.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 71.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 60.6 W (85.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.64 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.46 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 7.82 V / 9.09 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.273 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.4% (0.53 m2) | Array roof footprint density |
| **Cell Count & Technology** | 14 cells (Mono-c-Si) | Monofacial backsheet |

## How Many CertainTeed Apollo II - 71x Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (645 sq ft at 8 kW), and estimated Year-1 electric bill offset for CertainTeed Apollo II - 71x.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 85 | 6.04 kW | 485 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 113 | 8.02 kW | 645 sq ft | $2,007 | $3,394 |
| **10 kW Class** | 141 | 10.01 kW | 804 sq ft | $2,505 | $4,236 |

## How Many CertainTeed Apollo II - 71x Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for CertainTeed Apollo II - 71x (beta_Voc -0.273%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=9.64V and beta_Voc=-0.273%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 10.82 V | 55 panels | 595.1 V | 92 panels |
| **-10 C (14 F)** | 10.56 V | 56 panels | 591.4 V | 94 panels |
| **0 C (32 F)** | 10.3 V | 58 panels | 597.4 V | 97 panels |
| **25 C (77 F STC)** | 9.64 V | 62 panels | 597.7 V | 103 panels |

## Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 71x?

Closest cross-brand CEC competitors to CertainTeed Apollo II - 71x matched near 71.0 W STC and 9.64 V Voc, led by Merlin Solar Technologies Inc Solstice Shingle 72W-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc Solstice Shingle 72W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-72w-01/) Merlin Solar Technologies Inc | 72.0 W | +1.0 W | 9.65 V | 13.58% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 70W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-70w-01/) Merlin Solar Technologies Inc | 70.0 W | -1.0 W | 9.51 V | 13.21% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 68W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-68w-01/) Merlin Solar Technologies Inc | 68.0 W | -3.0 W | 9.37 V | 12.83% | 89.4% |
| [**HALEE Inc HST-61-E-FP**](https://epri-peac.com/solar-equipment/modules/halee-inc/halee-inc-hst-61-e-fp/) HALEE Inc | 61.0 W | -10.0 W | 9.5 V | 14.88% | 85.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 71x?

Evaluate CertainTeed Apollo II - 71x (71.0 W STC, 9.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 71x reaches 10.82 V per panel—exceeding 55 panels in series voids 600 V inverter warranties.
- Footprint constraint: 113 panels for an 8 kW build require 645 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 113 panels (645 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 71x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### CertainTeed Apollo II - 71x 8 kW Residential Fit

Needs 113 modules (645 sq ft) with a 15 A string OCPD, offsetting ~$2,007/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 56 panels (-10 C) or 55 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 60.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo II - 71x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

### How many CertainTeed Apollo II - 71x panels fit on a 600 V winter solar string?

At -10 C (14 F), CertainTeed Apollo II - 71x cold Voc rises from 9.64 V to 10.56 V (beta_Voc -0.273%/C), capping a 600 V string at 56 panels (591.4 V).

### How much roof area does an 8 kW array of CertainTeed Apollo II - 71x need?

An 8 kW DC system uses 113 CertainTeed Apollo II - 71x modules (8,023 W STC / 6,848 W PTC), covering roughly 645 sq ft and saving ~$2,007/yr at 18.54 c/kWh.

### How does CertainTeed Apollo II - 71x compare against Merlin Solar Technologies Inc Solstice Shingle 72W-01?

CertainTeed Apollo II - 71x outputs 71.0 W STC (9.64 V Voc, rank #21,635 of 21,677), while Merlin Solar Technologies Inc Solstice Shingle 72W-01 delivers 72.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare CertainTeed equipment, Merlin Solar Technologies Inc Solstice Shingle 72W-01 specs, utility payback rates, and NEC string calculators alongside CertainTeed Apollo II - 71x.

[All CertainTeed Certified Solar Models](https://epri-peac.com/solar-equipment/brands/certainteed/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From CertainTeed

- [All CertainTeed Specs](https://epri-peac.com/solar-equipment/brands/certainteed/)
- [CertainTeed CTM10455HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10455hc11-06/)
- [CertainTeed CTTC455HC12-08](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc455hc12-08/)
- [CertainTeed CTM10450HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10450hc11-06/)
- [CertainTeed CTM10445HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10445hc11-06/)
- [CertainTeed CTM10440HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/)
