# Centrosolar America VS-140C2 — CEC Solar Module Specifications

Manufacturer: [**Centrosolar America**](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) Registry: **CEC Verified Engineering Specification**

Centrosolar America VS-140C2 is a 140.0 W STC (130.1 W PTC) Thin Film solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 12.89% efficiency, 79.95 V Voc at 25 C, and 88.09 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 140.0 W

- **PTC Wattage** : 130.1 W

- **Voc @ 25C** : 79.95 V

- **Efficiency** : 12.89%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Centrosolar America VS-140C2 Compare Against Peer CEC Listings?

Engineering position of Centrosolar America VS-140C2 (140.0 W STC) vs. First Solar Inc FS-4122-3 across 106 CEC Thin Film solar modules.

Ranking #21,440 across 21,677 CEC solar panels (below all-CEC median; higher than 1.0% of peers), Centrosolar America VS-140C2 operates as a compact residential or specialty off-grid module sitting 22.5 W above the 117.5 W Thin Film median. Higher 79.95 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 58 panels occupy 678 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Centrosolar America VS-140C2 Fall Across Listed CEC Models?

Plots Centrosolar America VS-140C2 at 140.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Centrosolar America VS-140C2?

Benchmarks Centrosolar America VS-140C2 on STC wattage, thermal PTC/STC retention, and 12.89 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Centrosolar America VS-140C2?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Centrosolar America VS-140C2 by Centrosolar America.

Rank #21,440 / 21,677

### 140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,445

### 12.89% Aperture Efficiency

Power density 128.9 W/m2 (7.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 88.09 V at -10 C (528.5 V string) and 90.42 V at -20 C (6 max).

 8 kW Reference Array

### 58 Panels = 8,120 W STC

Occupies 63.0 m2 (678 sq ft) producing 7,546 W PTC; NEC 690.8 OCPD floor is 3.92 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 79.95 * (1 + (-0.291/100) * (-10 - 25)) = 88.09 V | OCPD = 1.56 * 2.51 = 3.92 A

Inputs from CEC Modules.csv for Centrosolar America VS-140C2: Voc=79.95 V, beta_Voc=-0.291%/C, Isc=2.51 A, STC=140.0 W, Area=1.086 m2.

**Result:** 6 panels max on 600 V (528.5 V); 58 panels for 8 kW (678 sq ft).

## What Are the Published CEC Specifications for Centrosolar America VS-140C2?

Laboratory test ratings recorded for Centrosolar America VS-140C2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America VS-140C2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 130.1 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 79.95 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 62.78 V / 2.23 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.291 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.89% (1.086 m2) | Array roof footprint density |
| **Cell Count & Technology** | 133 cells (Thin Film) | Monofacial backsheet |

## How Many Centrosolar America VS-140C2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (678 sq ft at 8 kW), and estimated Year-1 electric bill offset for Centrosolar America VS-140C2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 43 | 6.02 kW | 503 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 58 | 8.12 kW | 678 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 72 | 10.08 kW | 842 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Sibling wattage bins and frame colors grouped with Centrosolar America VS-140C2 under Centrosolar America to prevent duplicate spec pages.

Sibling CEC listings grouped into the Centrosolar America VS-140C2 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Centrosolar America VS-135C2** | 135.0 W | 125.4 W | 79.8 V | 61.64 V | 12.43% |
| **Centrosolar America VS-140C2** | 140.0 W | 130.1 W | 79.95 V | 62.78 V | 12.89% |
| **Centrosolar America VS-145C2** | 145.0 W | 134.8 W | 80.45 V | 63.87 V | 13.35% |

## How Many Centrosolar America VS-140C2 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Centrosolar America VS-140C2 (beta_Voc -0.291%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=79.95V and beta_Voc=-0.291%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 90.42 V | 6 panels | 542.5 V | 11 panels |
| **-10 C (14 F)** | 88.09 V | 6 panels | 528.5 V | 11 panels |
| **0 C (32 F)** | 85.77 V | 6 panels | 514.6 V | 11 panels |
| **25 C (77 F STC)** | 79.95 V | 7 panels | 559.6 V | 12 panels |

## Which Cross-Brand Solar Modules Compare Closest to Centrosolar America VS-140C2?

Closest cross-brand CEC competitors to Centrosolar America VS-140C2 matched near 140.0 W STC and 79.95 V Voc, led by First Solar Inc FS-4122-3.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**First Solar Inc FS-4122-3**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4122-3/) First Solar Inc | 122.5 W | -17.5 W | 88.7 V | 17.01% | 93.5% |
| [**First Solar Inc FS-4122A-3**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4122a-3/) First Solar Inc | 122.5 W | -17.5 W | 88.7 V | 17.01% | 93.5% |
| [**Toledo Solar Inc TS1**](https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/) Toledo Solar Inc | 115.0 W | -25.0 W | 87.1 V | 15.97% | 92.9% |
| [**First Solar Inc FS-4120-3**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4120-3/) First Solar Inc | 120.0 W | -20.0 W | 88.7 V | 16.67% | 93.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Centrosolar America VS-140C2?

Evaluate Centrosolar America VS-140C2 (140.0 W STC, 79.95 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America VS-140C2 reaches 90.42 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 678 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (678 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America VS-140C2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Centrosolar America VS-140C2 8 kW Residential Fit

Needs 58 modules (678 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare First Solar Inc FS-4122-3.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 130.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America VS-140C2 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Centrosolar America VS-140C2 panels fit on a 600 V winter solar string?

At -10 C (14 F), Centrosolar America VS-140C2 cold Voc rises from 79.95 V to 88.09 V (beta_Voc -0.291%/C), capping a 600 V string at 6 panels (528.5 V).

### How much roof area does an 8 kW array of Centrosolar America VS-140C2 need?

An 8 kW DC system uses 58 Centrosolar America VS-140C2 modules (8,120 W STC / 7,546 W PTC), covering roughly 678 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

### How does Centrosolar America VS-140C2 compare against First Solar Inc FS-4122-3?

Centrosolar America VS-140C2 outputs 140.0 W STC (79.95 V Voc, rank #21,440 of 21,677), while First Solar Inc FS-4122-3 delivers 122.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Centrosolar America equipment, First Solar Inc FS-4122-3 specs, utility payback rates, and NEC string calculators alongside Centrosolar America VS-140C2.

[All Centrosolar America Certified Solar Models](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Centrosolar America

- [All Centrosolar America Specs](https://epri-peac.com/solar-equipment/brands/centrosolar-america/)
- [Centrosolar America EM72 350BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350bw/)
- [Centrosolar America EM72 350SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350sw/)
- [Centrosolar America EM72 335BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335bw/)
- [Centrosolar America EM72 335SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335sw/)
- [Centrosolar America DM72 330](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-330/)