Centrosolar America VS-140C1 is a 140.0 W STC (129.8 W PTC) Thin Film solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 12.89% efficiency, 60.6 V Voc at 25 C, and 66.67 V cold Voc at -10 C (8 panels max per 600 V string).

- **STC Wattage** : 140.0 W

- **PTC Wattage** : 129.8 W

- **Voc @ 25C** : 60.6 V

- **Efficiency** : 12.89%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Centrosolar America VS-140C1 Compare Against Peer CEC Listings?

Solar engineering breakdown for Centrosolar America VS-140C1: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Across 106 Thin Film listings from Centrosolar America and peers, Centrosolar America VS-140C1 stands 22.5 W above the 117.5 W Thin Film median and strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Sizing 6 kW (43 panels) to 10 kW (72 panels) yields $1,507-$2,523/yr in baseline US bill offset. Higher 60.6 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C).

## Where Does Centrosolar America VS-140C1 Fall Across Listed CEC Models?

Distribution marker showing Centrosolar America VS-140C1 (140.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define Centrosolar America VS-140C1?

Dataset percentiles tracking Centrosolar America VS-140C1 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Do the Dataset Ranks Show for Centrosolar America VS-140C1?

Benchmark highlights for Centrosolar America VS-140C1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #21,440 / 21,677

### 140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,445

### 12.89% Aperture Efficiency

Power density 128.9 W/m2 (7.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

### 8 Panels Max @ -10 C (600 V)

Cold Voc reaches 66.67 V at -10 C (533.4 V string) and 68.4 V at -20 C (8 max).

 8 kW Reference Array

### 58 Panels = 8,120 W STC

Occupies 63.0 m2 (678 sq ft) producing 7,528 W PTC; NEC 690.8 OCPD floor is 5.37 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 60.6 * (1 + (-0.286/100) * (-10 - 25)) = 66.67 V | OCPD = 1.56 * 3.44 = 5.37 A

Inputs from CEC Modules.csv for Centrosolar America VS-140C1: Voc=60.6 V, beta_Voc=-0.286%/C, Isc=3.44 A, STC=140.0 W, Area=1.086 m2.

**Result:** 8 panels max on 600 V (533.4 V); 58 panels for 8 kW (678 sq ft).

## What Are the Published CEC Specifications for Centrosolar America VS-140C1?

Official CEC datasheet figures for Centrosolar America VS-140C1 (Thin Film) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America VS-140C1.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 129.8 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 60.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 3.44 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.0 V / 3.05 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.286 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.89% (1.086 m2) | Array roof footprint density |
| **Cell Count & Technology** | 100 cells (Thin Film) | Monofacial backsheet |

## How Many Centrosolar America VS-140C1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Centrosolar America VS-140C1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 43 | 6.02 kW | 503 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 58 | 8.12 kW | 678 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 72 | 10.08 kW | 842 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Consolidated Centrosolar America wattage variants sharing the Centrosolar America VS-140C1 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Centrosolar America VS-140C1 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Centrosolar America VS-135C1** | 135.0 W | 125.0 W | 59.5 V | 44.7 V | 12.43% |
| **Centrosolar America VS-140C1** | 140.0 W | 129.8 W | 60.6 V | 46.0 V | 12.89% |
| **Centrosolar America VS-145C1** | 145.0 W | 134.5 W | 61.5 V | 46.9 V | 13.35% |

## How Many Centrosolar America VS-140C1 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America VS-140C1 (66.67 V at 14 F).

Computed from Voc=60.6V and beta_Voc=-0.286%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 68.4 V | 8 panels | 547.2 V | 14 panels |
| **-10 C (14 F)** | 66.67 V | 8 panels | 533.4 V | 14 panels |
| **0 C (32 F)** | 64.93 V | 9 panels | 584.4 V | 15 panels |
| **25 C (77 F STC)** | 60.6 V | 9 panels | 545.4 V | 16 panels |

## Which Cross-Brand Solar Modules Compare Closest to Centrosolar America VS-140C1?

Competing CEC solar panels closest to Centrosolar America VS-140C1 in nameplate wattage and Voc, starting with Zhongshan Ruike New Energy Co Ltd RK-105-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Zhongshan Ruike New Energy Co Ltd RK-105-2**](https://epri-peac.com/solar-equipment/modules/zhongshan-ruike-new-energy-co-ltd/zhongshan-ruike-new-energy-co-ltd-rk-105-2/) Zhongshan Ruike New Energy Co Ltd | 105.0 W | -35.0 W | 59.1 V | 14.58% | 94.4% |
| [**First Solar Inc FS-3100-Plus**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-3100-plus/) First Solar Inc | 100.0 W | -40.0 W | 58.8 V | 13.89% | 94.8% |
| [**First Solar Inc FS-385**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-385/) First Solar Inc | 85.0 W | -55.0 W | 61.0 V | 11.81% | 95.1% |
| [**First Solar Inc FS-392-Plus**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-392-plus/) First Solar Inc | 92.5 W | -47.5 W | 57.7 V | 12.85% | 94.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Centrosolar America VS-140C1?

Evaluate Centrosolar America VS-140C1 (140.0 W STC, 60.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America VS-140C1 reaches 68.4 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 678 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (678 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America VS-140C1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Centrosolar America VS-140C1 8 kW Residential Fit

Needs 58 modules (678 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-105-2.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 129.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America VS-140C1 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Centrosolar America VS-140C1?

Multiplying Centrosolar America VS-140C1's 3.44 A short-circuit current by 1.56 equals 5.37 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Centrosolar America VS-140C1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 66.67 V cold Voc at 14 F and handles 3.44 A Isc; string inverters cap Centrosolar America VS-140C1 at 8 panels on 600 V.

### Is Centrosolar America VS-140C1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America VS-140C1 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

## Related Pages

Compare Centrosolar America equipment, Zhongshan Ruike New Energy Co Ltd RK-105-2 specs, utility payback rates, and NEC string calculators alongside Centrosolar America VS-140C1.

[All Centrosolar America Certified Solar Models](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Centrosolar America

- [All Centrosolar America Specs](https://epri-peac.com/solar-equipment/brands/centrosolar-america/)
- [Centrosolar America EM72 350BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350bw/)
- [Centrosolar America EM72 350SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350sw/)
- [Centrosolar America EM72 335BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335bw/)
- [Centrosolar America EM72 335SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335sw/)
- [Centrosolar America DM72 330](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-330/)