title: "Centrosolar America DP72 270 Specs (270.0W, 43.85V Voc)"
url: https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-270/
description: "CEC datasheet for Centrosolar America DP72 270: 270.0W STC, 43.85V Voc, 30-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Centrosolar America DP72 270 — CEC Solar Module Specifications

Manufacturer: [**Centrosolar America**](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) Registry: **CEC Verified Engineering Specification**

Centrosolar America DP72 270 is a 270.0 W STC (238.6 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.89% efficiency, 43.85 V Voc at 25 C, and 49.38 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 270.0 W

- **PTC Wattage** : 238.6 W

- **Voc @ 25C** : 43.85 V

- **Efficiency** : 13.89%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Centrosolar America DP72 270 Compare Against Peer CEC Listings?

Solar engineering breakdown for Centrosolar America DP72 270: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 270.0 W STC and 238.6 W PTC, Centrosolar America DP72 270 sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). Mid-range 43.85 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Anhui Rinengzhongtian Semiconductor Development QJM270-72 rates 270.0 W.

## Where Does Centrosolar America DP72 270 Fall Across Listed CEC Models?

Distribution marker showing Centrosolar America DP72 270 (270.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Centrosolar America DP72 270?

Dataset percentiles tracking Centrosolar America DP72 270 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Centrosolar America DP72 270?

Benchmark highlights for Centrosolar America DP72 270 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,572 / 21,677

### 270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,983

### 13.89% Aperture Efficiency

Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.38 V at -10 C (592.6 V string) and 50.95 V at -20 C (11 max).

 8 kW Reference Array

### 30 Panels = 8,100 W STC

Occupies 58.3 m2 (628 sq ft) producing 7,158 W PTC; NEC 690.8 OCPD floor is 12.62 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.85 * (1 + (-0.36/100) * (-10 - 25)) = 49.38 V | OCPD = 1.56 * 8.09 = 12.62 A

Inputs from CEC Modules.csv for Centrosolar America DP72 270: Voc=43.85 V, beta_Voc=-0.36%/C, Isc=8.09 A, STC=270.0 W, Area=1.944 m2.

**Result:** 12 panels max on 600 V (592.6 V); 30 panels for 8 kW (628 sq ft).

## What Are the Published CEC Specifications for Centrosolar America DP72 270?

Official CEC datasheet figures for Centrosolar America DP72 270 (Multi-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DP72 270.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 238.6 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.55 V / 7.59 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.36 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.89% (1.944 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Centrosolar America DP72 270 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Centrosolar America DP72 270 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.21 kW | 481 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 30 | 8.1 kW | 628 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 38 | 10.26 kW | 795 sq ft | $2,568 | $4,342 |

## How Many Centrosolar America DP72 270 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP72 270 (49.38 V at 14 F).

Computed from Voc=43.85V and beta_Voc=-0.36%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.95 V | 11 panels | 560.5 V | 19 panels |
| **-10 C (14 F)** | 49.38 V | 12 panels | 592.6 V | 20 panels |
| **0 C (32 F)** | 47.8 V | 12 panels | 573.6 V | 20 panels |
| **25 C (77 F STC)** | 43.85 V | 13 panels | 570.1 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP72 270?

Competing CEC solar panels closest to Centrosolar America DP72 270 in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJM270-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJM270-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm270-72/) Anhui Rinengzhongtian Semiconductor Development | 270.0 W | Tie (0 W) | 43.67 V | 13.92% | 89.6% |
| [**AXITEC AC-270P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-270p-156-72s/) AXITEC | 270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| [**Advance Power API-M270**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m270/) Advance Power | 270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| [**Auxin Solar AXN6M612T270**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t270/) Auxin Solar | 270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Centrosolar America DP72 270?

Evaluate Centrosolar America DP72 270 (270.0 W STC, 43.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP72 270 reaches 50.95 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (628 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America DP72 270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Centrosolar America DP72 270 8 kW Residential Fit

Needs 30 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM270-72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 238.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DP72 270 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Centrosolar America DP72 270 panels fit on a 600 V winter solar string?

At -10 C (14 F), Centrosolar America DP72 270 cold Voc rises from 43.85 V to 49.38 V (beta_Voc -0.36%/C), capping a 600 V string at 12 panels (592.6 V).

### How much roof area does an 8 kW array of Centrosolar America DP72 270 need?

An 8 kW DC system uses 30 Centrosolar America DP72 270 modules (8,100 W STC / 7,158 W PTC), covering roughly 628 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does Centrosolar America DP72 270 compare against Anhui Rinengzhongtian Semiconductor Development QJM270-72?

Centrosolar America DP72 270 outputs 270.0 W STC (43.85 V Voc, rank #18,572 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJM270-72 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Centrosolar America equipment, Anhui Rinengzhongtian Semiconductor Development QJM270-72 specs, utility payback rates, and NEC string calculators alongside Centrosolar America DP72 270.

[All Centrosolar America Certified Solar Models](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Centrosolar America

- [All Centrosolar America Specs](https://epri-peac.com/solar-equipment/brands/centrosolar-america/)
- [Centrosolar America EM72 350BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350bw/)
- [Centrosolar America EM72 350SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350sw/)
- [Centrosolar America EM72 335BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335bw/)
- [Centrosolar America EM72 335SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335sw/)
- [Centrosolar America DM72 330](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-330/)