title: "Centrosolar America DP48 200 Specs (200.0W, 30.12V Voc)"
url: https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp48-200/
description: "CEC datasheet for Centrosolar America DP48 200: 200.0W STC, 30.12V Voc, 40-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Centrosolar America DP48 200 — CEC Solar Module Specifications

Manufacturer: [**Centrosolar America**](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) Registry: **CEC Verified Engineering Specification**

Centrosolar America DP48 200 is a 200.0 W STC (177.2 W PTC) Multi-c-Si solar module ranking #21,027 of 21,677 CEC listings (below all-CEC median; higher than 2.7% of peers). It delivers 15.09% efficiency, 30.12 V Voc at 25 C, and 33.92 V cold Voc at -10 C (17 panels max per 600 V string).

- **STC Wattage** : 200.0 W

- **PTC Wattage** : 177.2 W

- **Voc @ 25C** : 30.12 V

- **Efficiency** : 15.09%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Centrosolar America DP48 200 Compare Against Peer CEC Listings?

Solar engineering breakdown for Centrosolar America DP48 200: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Centrosolar America and peers, Centrosolar America DP48 200 stands 78.8 W below the 278.8 W Multi-c-Si median and typical 88.6% PTC-to-STC thermal output (177.2 W real-world rating). Sizing 6 kW (30 panels) to 10 kW (50 panels) yields $1,502-$2,503/yr in baseline US bill offset. Lower 30.12 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters.

## Where Does Centrosolar America DP48 200 Fall Across Listed CEC Models?

Distribution marker showing Centrosolar America DP48 200 (200.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Centrosolar America DP48 200?

Dataset percentiles tracking Centrosolar America DP48 200 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Centrosolar America DP48 200?

Benchmark highlights for Centrosolar America DP48 200 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,027 / 21,677

### 200.0 W STC · Higher Than 2.7%

200.0 W STC (-185.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,614

### 15.09% Aperture Efficiency

Power density 150.9 W/m2 (4.82 percentage points below 19.91% CEC median). PTC/STC ratio: 88.6% (rank #21,091).

NEC 690.7 Limit

### 17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.92 V at -10 C (576.6 V string) and 35.0 V at -20 C (17 max).

 8 kW Reference Array

### 40 Panels = 8,000 W STC

Occupies 53.0 m2 (570 sq ft) producing 7,088 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 30.12 * (1 + (-0.36/100) * (-10 - 25)) = 33.92 V | OCPD = 1.56 * 8.63 = 13.46 A

Inputs from CEC Modules.csv for Centrosolar America DP48 200: Voc=30.12 V, beta_Voc=-0.36%/C, Isc=8.63 A, STC=200.0 W, Area=1.325 m2.

**Result:** 17 panels max on 600 V (576.6 V); 40 panels for 8 kW (570 sq ft).

## What Are the Published CEC Specifications for Centrosolar America DP48 200?

Official CEC datasheet figures for Centrosolar America DP48 200 (Multi-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DP48 200.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 200.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 177.2 W (88.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 30.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 24.6 V / 8.13 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.36 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.09% (1.325 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Centrosolar America DP48 200 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Centrosolar America DP48 200 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 30 | 6.0 kW | 428 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 40 | 8.0 kW | 570 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 50 | 10.0 kW | 713 sq ft | $2,503 | $4,232 |

## How Many Centrosolar America DP48 200 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP48 200 (33.92 V at 14 F).

Computed from Voc=30.12V and beta_Voc=-0.36%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 35.0 V | 17 panels | 595.0 V | 28 panels |
| **-10 C (14 F)** | 33.92 V | 17 panels | 576.6 V | 29 panels |
| **0 C (32 F)** | 32.83 V | 18 panels | 590.9 V | 30 panels |
| **25 C (77 F STC)** | 30.12 V | 19 panels | 572.3 V | 33 panels |

## Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP48 200?

Competing CEC solar panels closest to Centrosolar America DP48 200 in nameplate wattage and Voc, starting with Gintung Energy ASEC-210G6M68.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-210G6M68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-210g6m68/) Gintung Energy | 210.0 W | +10.0 W | 30.14 V | 16.1% | 88.1% |
| [**Gintung Energy ASEC-210G6S68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-210g6s68/) Gintung Energy | 210.0 W | +10.0 W | 30.14 V | 16.1% | 87.8% |
| [**Gintung Energy GTEC-210G6M68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-210g6m68/) Gintung Energy | 210.0 W | +10.0 W | 30.14 V | 16.1% | 88.1% |
| [**Gintung Energy GTEC-210G6S68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-210g6s68/) Gintung Energy | 210.0 W | +10.0 W | 30.14 V | 16.1% | 87.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Centrosolar America DP48 200?

Evaluate Centrosolar America DP48 200 (200.0 W STC, 30.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP48 200 reaches 35.0 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 40 panels for an 8 kW build require 570 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (570 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America DP48 200 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Centrosolar America DP48 200 8 kW Residential Fit

Needs 40 modules (570 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Gintung Energy ASEC-210G6M68.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 177.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DP48 200 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Centrosolar America DP48 200?

Multiplying Centrosolar America DP48 200's 8.63 A short-circuit current by 1.56 equals 13.46 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Centrosolar America DP48 200 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 33.92 V cold Voc at 14 F and handles 8.63 A Isc; string inverters cap Centrosolar America DP48 200 at 17 panels on 600 V.

### Is Centrosolar America DP48 200 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America DP48 200 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

## Related Pages

Compare Centrosolar America equipment, Gintung Energy ASEC-210G6M68 specs, utility payback rates, and NEC string calculators alongside Centrosolar America DP48 200.

[All Centrosolar America Certified Solar Models](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Centrosolar America

- [All Centrosolar America Specs](https://epri-peac.com/solar-equipment/brands/centrosolar-america/)
- [Centrosolar America EM72 350BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350bw/)
- [Centrosolar America EM72 350SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350sw/)
- [Centrosolar America EM72 335BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335bw/)
- [Centrosolar America EM72 335SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335sw/)
- [Centrosolar America DM72 330](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-330/)