CEC PV Module

# Centrosolar America DP36 140 — CEC Solar Module Specifications

Manufacturer: [**Centrosolar America**](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) Registry: **CEC Verified Engineering Specification**

Centrosolar America DP36 140 is a 140.0 W STC (123.7 W PTC) Multi-c-Si solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.85% efficiency, 22.15 V Voc at 25 C, and 24.94 V cold Voc at -10 C (24 panels max per 600 V string).

- **STC Wattage** : 140.0 W

- **PTC Wattage** : 123.7 W

- **Voc @ 25C** : 22.15 V

- **Efficiency** : 13.85%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Centrosolar America DP36 140 Compare Against Peer CEC Listings?

Solar engineering breakdown for Centrosolar America DP36 140: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Centrosolar America and peers, Centrosolar America DP36 140 stands 138.8 W below the 278.8 W Multi-c-Si median and typical 88.4% PTC-to-STC thermal output (123.7 W real-world rating). Sizing 6 kW (43 panels) to 10 kW (72 panels) yields $1,507-$2,523/yr in baseline US bill offset. Lower 22.15 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters.

## Where Does Centrosolar America DP36 140 Fall Across Listed CEC Models?

Distribution marker showing Centrosolar America DP36 140 (140.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Centrosolar America DP36 140?

Dataset percentiles tracking Centrosolar America DP36 140 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Centrosolar America DP36 140?

Benchmark highlights for Centrosolar America DP36 140 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,440 / 21,677

### 140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,010

### 13.85% Aperture Efficiency

Power density 138.5 W/m2 (6.06 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

### 24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.94 V at -10 C (598.6 V string) and 25.74 V at -20 C (23 max).

 8 kW Reference Array

### 58 Panels = 8,120 W STC

Occupies 58.6 m2 (631 sq ft) producing 7,175 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.15 * (1 + (-0.36/100) * (-10 - 25)) = 24.94 V | OCPD = 1.56 * 8.53 = 13.31 A

Inputs from CEC Modules.csv for Centrosolar America DP36 140: Voc=22.15 V, beta_Voc=-0.36%/C, Isc=8.53 A, STC=140.0 W, Area=1.011 m2.

**Result:** 24 panels max on 600 V (598.6 V); 58 panels for 8 kW (631 sq ft).

## What Are the Published CEC Specifications for Centrosolar America DP36 140?

Official CEC datasheet figures for Centrosolar America DP36 140 (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DP36 140.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 123.7 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 22.15 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 17.43 V / 8.03 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.36 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.85% (1.011 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Centrosolar America DP36 140 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Centrosolar America DP36 140 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 43 | 6.02 kW | 468 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 58 | 8.12 kW | 631 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 72 | 10.08 kW | 784 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Consolidated Centrosolar America wattage variants sharing the Centrosolar America DP36 140 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Centrosolar America DP36 140 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Centrosolar America DP36 130** | 130.0 W | 114.7 W | 21.69 V | 16.41 V | 12.86% |
| **Centrosolar America DP36 135** | 135.0 W | 119.2 W | 21.9 V | 16.92 V | 13.36% |
| **Centrosolar America DP36 140** | 140.0 W | 123.7 W | 22.15 V | 17.43 V | 13.85% |
| **Centrosolar America DP36 145** | 145.0 W | 128.3 W | 22.37 V | 17.9 V | 14.35% |

## How Many Centrosolar America DP36 140 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP36 140 (24.94 V at 14 F).

Computed from Voc=22.15V and beta_Voc=-0.36%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 25.74 V | 23 panels | 592.0 V | 38 panels |
| **-10 C (14 F)** | 24.94 V | 24 panels | 598.6 V | 40 panels |
| **0 C (32 F)** | 24.14 V | 24 panels | 579.4 V | 41 panels |
| **25 C (77 F STC)** | 22.15 V | 27 panels | 598.0 V | 45 panels |

## Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP36 140?

Competing CEC solar panels closest to Centrosolar America DP36 140 in nameplate wattage and Voc, starting with Solartech Energy ASC-6P-36-140.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Solartech Energy ASC-6P-36-140**](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-36-140/) Solartech Energy | 140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| [**US Solar USS-QCMI2-36-140**](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi2-36-140/) US Solar | 140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| [**Auxin Solar AXN6M409T140**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m409t140/) Auxin Solar | 140.0 W | Tie (0 W) | 22.03 V | 14.29% | 89.3% |
| [**APOS Energy AS140**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-as140/) APOS Energy | 140.0 W | Tie (0 W) | 22.33 V | 13.69% | 89.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Centrosolar America DP36 140?

Evaluate Centrosolar America DP36 140 (140.0 W STC, 22.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP36 140 reaches 25.74 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 631 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (631 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America DP36 140 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Centrosolar America DP36 140 8 kW Residential Fit

Needs 58 modules (631 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Solartech Energy ASC-6P-36-140.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 123.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DP36 140 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Centrosolar America DP36 140?

Multiplying Centrosolar America DP36 140's 8.53 A short-circuit current by 1.56 equals 13.31 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Centrosolar America DP36 140 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 24.94 V cold Voc at 14 F and handles 8.53 A Isc; string inverters cap Centrosolar America DP36 140 at 24 panels on 600 V.

### Is Centrosolar America DP36 140 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America DP36 140 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

## Related Pages

Compare Centrosolar America equipment, Solartech Energy ASC-6P-36-140 specs, utility payback rates, and NEC string calculators alongside Centrosolar America DP36 140.

[All Centrosolar America Certified Solar Models](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Centrosolar America

- [All Centrosolar America Specs](https://epri-peac.com/solar-equipment/brands/centrosolar-america/)
- [Centrosolar America EM72 350BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350bw/)
- [Centrosolar America EM72 350SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350sw/)
- [Centrosolar America EM72 335BW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335bw/)
- [Centrosolar America EM72 335SW](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335sw/)
- [Centrosolar America DM72 330](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-330/)