# Caterpillar Inc PVT112 ARC — CEC Solar Module Specifications

Manufacturer: [**Caterpillar Inc**](https://epri-peac.com/solar-equipment/brands/caterpillar-inc/) Registry: **CEC Verified Engineering Specification**

Caterpillar Inc PVT112 ARC is a 112.5 W STC (104.5 W PTC) Thin Film solar module ranking #21,521 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.62% efficiency, 87.7 V Voc at 25 C, and 95.93 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 112.5 W

- **PTC Wattage** : 104.5 W

- **Voc @ 25C** : 87.7 V

- **Efficiency** : 15.62%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Caterpillar Inc PVT112 ARC Compare Against Peer CEC Listings?

Engineering position of Caterpillar Inc PVT112 ARC (112.5 W STC) vs. First Solar Inc FS-4112-2 across 106 CEC Thin Film solar modules.

Ranking #21,521 across 21,677 CEC solar panels (below all-CEC median; higher than 0.7% of peers), Caterpillar Inc PVT112 ARC operates as a compact residential or specialty off-grid module sitting 5.0 W below the 117.5 W Thin Film median. Higher 87.7 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 72 panels occupy 558 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Caterpillar Inc PVT112 ARC Fall Across Listed CEC Models?

Plots Caterpillar Inc PVT112 ARC at 112.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Caterpillar Inc PVT112 ARC?

Benchmarks Caterpillar Inc PVT112 ARC on STC wattage, thermal PTC/STC retention, and 15.62 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Caterpillar Inc PVT112 ARC?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Caterpillar Inc PVT112 ARC by Caterpillar Inc.

Rank #21,521 / 21,677

### 112.5 W STC · Higher Than 0.7%

112.5 W STC (-272.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #18,755

### 15.62% Aperture Efficiency

Power density 156.2 W/m2 (4.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 95.93 V at -10 C (575.6 V string) and 98.28 V at -20 C (6 max).

 8 kW Reference Array

### 72 Panels = 8,100 W STC

Occupies 51.8 m2 (558 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 2.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 87.7 * (1 + (-0.268/100) * (-10 - 25)) = 95.93 V | OCPD = 1.56 * 1.75 = 2.73 A

Inputs from CEC Modules.csv for Caterpillar Inc PVT112 ARC: Voc=87.7 V, beta_Voc=-0.268%/C, Isc=1.75 A, STC=112.5 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (575.6 V); 72 panels for 8 kW (558 sq ft).

## What Are the Published CEC Specifications for Caterpillar Inc PVT112 ARC?

Laboratory test ratings recorded for Caterpillar Inc PVT112 ARC (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Caterpillar Inc PVT112 ARC.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 112.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 104.5 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 87.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 70.2 V / 1.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.268 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.62% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many Caterpillar Inc PVT112 ARC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (558 sq ft at 8 kW), and estimated Year-1 electric bill offset for Caterpillar Inc PVT112 ARC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 54 | 6.08 kW | 419 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 72 | 8.1 kW | 558 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 89 | 10.01 kW | 690 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?

Sibling wattage bins and frame colors grouped with Caterpillar Inc PVT112 ARC under Caterpillar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the Caterpillar Inc PVT112 ARC wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Caterpillar Inc PVT105 ARC** | 105.0 W | 97.4 W | 86.0 V | 67.8 V | 14.58% |
| **Caterpillar Inc PVT107 ARC** | 107.5 W | 99.7 W | 86.6 V | 68.6 V | 14.93% |
| **Caterpillar Inc PVT110 ARC** | 110.0 W | 102.1 W | 87.2 V | 69.4 V | 15.28% |
| **Caterpillar Inc PVT112 ARC** | 112.5 W | 104.5 W | 87.7 V | 70.2 V | 15.62% |
| **Caterpillar Inc PVT115 ARC** | 115.0 W | 105.2 W | 87.8 V | 70.5 V | 15.97% |
| **Caterpillar Inc PVT117 ARC** | 117.5 W | 107.5 W | 88.2 V | 71.2 V | 16.32% |

## How Many Caterpillar Inc PVT112 ARC Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Caterpillar Inc PVT112 ARC (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=87.7V and beta_Voc=-0.268%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 98.28 V | 6 panels | 589.7 V | 10 panels |
| **-10 C (14 F)** | 95.93 V | 6 panels | 575.6 V | 10 panels |
| **0 C (32 F)** | 93.58 V | 6 panels | 561.5 V | 10 panels |
| **25 C (77 F STC)** | 87.7 V | 6 panels | 526.2 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVT112 ARC?

Closest cross-brand CEC competitors to Caterpillar Inc PVT112 ARC matched near 112.5 W STC and 87.7 V Voc, led by First Solar Inc FS-4112-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**First Solar Inc FS-4112-2**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4112-2/) First Solar Inc | 112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| [**First Solar Inc FS-4112A-2**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4112a-2/) First Solar Inc | 112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| [**First Solar Inc FS-4112-3**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4112-3/) First Solar Inc | 112.5 W | Tie (0 W) | 87.0 V | 15.62% | 93.2% |
| [**First Solar Inc FS-4112A-3**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4112a-3/) First Solar Inc | 112.5 W | Tie (0 W) | 87.0 V | 15.62% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVT112 ARC?

Evaluate Caterpillar Inc PVT112 ARC (112.5 W STC, 87.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVT112 ARC reaches 98.28 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 72 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 72 panels (558 sq ft).
- 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVT112 ARC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Caterpillar Inc PVT112 ARC 8 kW Residential Fit

Needs 72 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare First Solar Inc FS-4112-2.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Caterpillar Inc PVT112 ARC by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Caterpillar Inc PVT112 ARC panels fit on a 600 V winter solar string?

At -10 C (14 F), Caterpillar Inc PVT112 ARC cold Voc rises from 87.7 V to 95.93 V (beta_Voc -0.268%/C), capping a 600 V string at 6 panels (575.6 V).

### How much roof area does an 8 kW array of Caterpillar Inc PVT112 ARC need?

An 8 kW DC system uses 72 Caterpillar Inc PVT112 ARC modules (8,100 W STC / 7,524 W PTC), covering roughly 558 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does Caterpillar Inc PVT112 ARC compare against First Solar Inc FS-4112-2?

Caterpillar Inc PVT112 ARC outputs 112.5 W STC (87.7 V Voc, rank #21,521 of 21,677), while First Solar Inc FS-4112-2 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Caterpillar Inc equipment, First Solar Inc FS-4112-2 specs, utility payback rates, and NEC string calculators alongside Caterpillar Inc PVT112 ARC.

[All Caterpillar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/caterpillar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Caterpillar Inc

- [All Caterpillar Inc Specs](https://epri-peac.com/solar-equipment/brands/caterpillar-inc/)
- [Caterpillar Inc PVC455MB03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc455mb03h/)
- [Caterpillar Inc PVC455MP03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc455mp03h/)
- [Caterpillar Inc PVC435MB03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc435mb03h/)
- [Caterpillar Inc PVC435MP03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc435mp03h/)
- [Caterpillar Inc PVC380MP03](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc380mp03/)