title: "Caterpillar Inc PVC435MP03H Specs (435.0W, 48.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc435mp03h/
description: "CEC datasheet for Caterpillar Inc PVC435MP03H: 435.0W STC, 48.7V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Caterpillar Inc PVC435MP03H — CEC Solar Module Specifications

Manufacturer: [**Caterpillar Inc**](https://epri-peac.com/solar-equipment/brands/caterpillar-inc/) Registry: **CEC Verified Engineering Specification**

Caterpillar Inc PVC435MP03H is a 435.0 W STC (407.1 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.52% efficiency, 48.7 V Voc at 25 C, and 53.22 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 407.1 W

- **Voc @ 25C** : 48.7 V

- **Efficiency** : 20.52%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Caterpillar Inc PVC435MP03H Compare Against Peer CEC Listings?

Engineering position of Caterpillar Inc PVC435MP03H (435.0 W STC) vs. CSI Solar Co Ltd CS3W-435P across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Caterpillar Inc PVC435MP03H pairs strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677) with 48.7 V nominal Voc. An 8 kW residential build (8,265 W DC, 7,735 W PTC) saves ~$2,070/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3W-435P offers a 435.0 W alternative.

## Where Does Caterpillar Inc PVC435MP03H Fall Across Listed CEC Models?

Plots Caterpillar Inc PVC435MP03H at 435.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Caterpillar Inc PVC435MP03H?

Benchmarks Caterpillar Inc PVC435MP03H on STC wattage, thermal PTC/STC retention, and 20.52 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Caterpillar Inc PVC435MP03H?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Caterpillar Inc PVC435MP03H by Caterpillar Inc.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,460

### 20.52% Aperture Efficiency

Power density 205.2 W/m2 (0.61 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.22 V at -10 C (585.4 V string) and 54.51 V at -20 C (11 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,735 W PTC; NEC 690.8 OCPD floor is 17.77 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.265/100) * (-10 - 25)) = 53.22 V | OCPD = 1.56 * 11.39 = 17.77 A

Inputs from CEC Modules.csv for Caterpillar Inc PVC435MP03H: Voc=48.7 V, beta_Voc=-0.265%/C, Isc=11.39 A, STC=435.0 W, Area=2.12 m2.

**Result:** 11 panels max on 600 V (585.4 V); 19 panels for 8 kW (434 sq ft).

## What Are the Published CEC Specifications for Caterpillar Inc PVC435MP03H?

Laboratory test ratings recorded for Caterpillar Inc PVC435MP03H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Caterpillar Inc PVC435MP03H.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 407.1 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.39 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.9 V / 10.64 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.265 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.52% (2.12 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Caterpillar Inc PVC435MP03H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (434 sq ft at 8 kW), and estimated Year-1 electric bill offset for Caterpillar Inc PVC435MP03H.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 319 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 434 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 525 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?

Sibling wattage bins and frame colors grouped with Caterpillar Inc PVC435MP03H under Caterpillar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the Caterpillar Inc PVC435MP03H wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Caterpillar Inc PVC425MP03H** | 425.0 W | 397.5 W | 48.3 V | 40.5 V | 20.05% |
| **Caterpillar Inc PVC430MP03H** | 430.0 W | 402.3 W | 48.5 V | 40.7 V | 20.28% |
| **Caterpillar Inc PVC435MP03H** | 435.0 W | 407.1 W | 48.7 V | 40.9 V | 20.52% |
| **Caterpillar Inc PVC440MP03H** | 440.0 W | 411.9 W | 48.9 V | 41.1 V | 20.75% |
| **Caterpillar Inc PVC445MP03H** | 445.0 W | 416.7 W | 49.1 V | 41.3 V | 20.99% |

## How Many Caterpillar Inc PVC435MP03H Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Caterpillar Inc PVC435MP03H (beta_Voc -0.265%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=48.7V and beta_Voc=-0.265%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.51 V | 11 panels | 599.6 V | 18 panels |
| **-10 C (14 F)** | 53.22 V | 11 panels | 585.4 V | 18 panels |
| **0 C (32 F)** | 51.93 V | 11 panels | 571.2 V | 19 panels |
| **25 C (77 F STC)** | 48.7 V | 12 panels | 584.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC435MP03H?

Closest cross-brand CEC competitors to Caterpillar Inc PVC435MP03H matched near 435.0 W STC and 48.7 V Voc, led by CSI Solar Co Ltd CS3W-435P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3W-435P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3w-435p/) CSI Solar Co Ltd | 435.0 W | Tie (0 W) | 48.6 V | 20.33% | 92.4% |
| [**Boviet Solar Technology Co Ltd BVM6612M-435S-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-435s-h-hc/) Boviet Solar Technology Co Ltd | 435.0 W | Tie (0 W) | 48.45 V | 19.77% | 93.7% |
| [**AXITEC AC-435MB/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-435mb-144v/) AXITEC | 435.0 W | Tie (0 W) | 49.1 V | 20.33% | 92.6% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m772f-435w/) Dehui Solar Power (Vietnam) CoLtd | 435.0 W | Tie (0 W) | 49.1 V | 20.33% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC435MP03H?

Evaluate Caterpillar Inc PVC435MP03H (435.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC435MP03H reaches 54.51 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (434 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC435MP03H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Caterpillar Inc PVC435MP03H 8 kW Residential Fit

Needs 19 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3W-435P.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 407.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Caterpillar Inc PVC435MP03H by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Caterpillar Inc PVC435MP03H?

Multiplying Caterpillar Inc PVC435MP03H's 11.39 A short-circuit current by 1.56 equals 17.77 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Caterpillar Inc PVC435MP03H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.22 V cold Voc at 14 F and handles 11.39 A Isc; string inverters cap Caterpillar Inc PVC435MP03H at 11 panels on 600 V.

### Is Caterpillar Inc PVC435MP03H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Caterpillar Inc PVC435MP03H rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

## Related Pages

Compare Caterpillar Inc equipment, CSI Solar Co Ltd CS3W-435P specs, utility payback rates, and NEC string calculators alongside Caterpillar Inc PVC435MP03H.

[All Caterpillar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/caterpillar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Caterpillar Inc

- [All Caterpillar Inc Specs](https://epri-peac.com/solar-equipment/brands/caterpillar-inc/)
- [Caterpillar Inc PVC455MB03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc455mb03h/)
- [Caterpillar Inc PVC455MP03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc455mp03h/)
- [Caterpillar Inc PVC435MB03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc435mb03h/)
- [Caterpillar Inc PVC380MP03](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc380mp03/)
- [Caterpillar Inc PVC380MP03H](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc380mp03h/)