title: "BYD Company Limited BYD400MIK-36 Specs (410.0W, 49.21V Voc)"
url: https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd400mik-36/
description: "CEC datasheet for BYD Company Limited BYD400MIK-36: 410.0W STC, 49.21V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# BYD Company Limited BYD400MIK-36 — CEC Solar Module Specifications

Manufacturer: [**BYD Company Limited**](https://epri-peac.com/solar-equipment/brands/byd-company-limited/) Registry: **CEC Verified Engineering Specification**

BYD Company Limited BYD400MIK-36 is a 410.0 W STC (385.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.4% efficiency, 49.21 V Voc at 25 C, and 53.76 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 385.2 W

- **Voc @ 25C** : 49.21 V

- **Efficiency** : 20.4%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does BYD Company Limited BYD400MIK-36 Compare Against Peer CEC Listings?

Solar engineering breakdown for BYD Company Limited BYD400MIK-36: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from BYD Company Limited and peers, BYD Company Limited BYD400MIK-36 stands equal to the 410.0 W Mono-c-Si median and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Higher 49.21 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does BYD Company Limited BYD400MIK-36 Fall Across Listed CEC Models?

Distribution marker showing BYD Company Limited BYD400MIK-36 (410.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define BYD Company Limited BYD400MIK-36?

Dataset percentiles tracking BYD Company Limited BYD400MIK-36 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for BYD Company Limited BYD400MIK-36?

Benchmark highlights for BYD Company Limited BYD400MIK-36 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,952

### 20.4% Aperture Efficiency

Power density 204.0 W/m2 (0.49 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.76 V at -10 C (591.4 V string) and 55.06 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 40.2 m2 (433 sq ft) producing 7,704 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.21 * (1 + (-0.264/100) * (-10 - 25)) = 53.76 V | OCPD = 1.56 * 10.29 = 16.05 A

Inputs from CEC Modules.csv for BYD Company Limited BYD400MIK-36: Voc=49.21 V, beta_Voc=-0.264%/C, Isc=10.29 A, STC=410.0 W, Area=2.01 m2.

**Result:** 11 panels max on 600 V (591.4 V); 20 panels for 8 kW (433 sq ft).

## What Are the Published CEC Specifications for BYD Company Limited BYD400MIK-36?

Official CEC datasheet figures for BYD Company Limited BYD400MIK-36 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for BYD Company Limited BYD400MIK-36.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 385.2 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.21 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.29 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.87 V / 9.79 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.264 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.4% (2.01 m2) | Array roof footprint density |
| **Cell Count & Technology** | 24 cells (Mono-c-Si) | Monofacial backsheet |

## How Many BYD Company Limited BYD400MIK-36 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many BYD Company Limited BYD400MIK-36 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 325 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 433 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 541 sq ft | $2,565 | $4,338 |

## Which Sibling Wattage & Trim Variants Belong to This BYD Company Limited Series?

Consolidated BYD Company Limited wattage variants sharing the BYD Company Limited BYD400MIK-36 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the BYD Company Limited BYD400MIK-36 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **BYD Company Limited BYD410MIK-36** | 400.0 W | 375.6 W | 49.78 V | 41.32 V | 19.9% |
| **BYD Company Limited BYD405MIK-36** | 405.0 W | 380.4 W | 49.49 V | 41.1 V | 20.15% |
| **BYD Company Limited BYD400MIK-36** | 410.0 W | 385.2 W | 49.21 V | 40.87 V | 20.4% |
| **BYD Company Limited BYD395MIK-36** | 415.0 W | 390.0 W | 48.92 V | 40.65 V | 20.65% |
| **BYD Company Limited BYD390MIK-36** | 420.0 W | 394.8 W | 48.64 V | 40.42 V | 20.9% |

## How Many BYD Company Limited BYD400MIK-36 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on BYD Company Limited BYD400MIK-36 (53.76 V at 14 F).

Computed from Voc=49.21V and beta_Voc=-0.264%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.06 V | 10 panels | 550.6 V | 18 panels |
| **-10 C (14 F)** | 53.76 V | 11 panels | 591.4 V | 18 panels |
| **0 C (32 F)** | 52.46 V | 11 panels | 577.1 V | 19 panels |
| **25 C (77 F STC)** | 49.21 V | 12 panels | 590.5 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to BYD Company Limited BYD400MIK-36?

Competing CEC solar panels closest to BYD Company Limited BYD400MIK-36 in nameplate wattage and Voc, starting with AXITEC AC-410MB/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-410MB/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mb-144v/) AXITEC | 410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m872w-410w/) Dehui Solar Power (Vietnam) CoLtd | 410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
| [**Auxin Solar AXNG1M410B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410b/) Auxin Solar | 410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| [**Auxin Solar AXNG1M410W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410w/) Auxin Solar | 410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for BYD Company Limited BYD400MIK-36?

Evaluate BYD Company Limited BYD400MIK-36 (410.0 W STC, 49.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), BYD Company Limited BYD400MIK-36 reaches 55.06 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 433 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (433 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of BYD Company Limited BYD400MIK-36 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### BYD Company Limited BYD400MIK-36 8 kW Residential Fit

Needs 20 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-410MB/144V.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 385.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for BYD Company Limited BYD400MIK-36 by BYD Company Limited grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for BYD Company Limited BYD400MIK-36?

Multiplying BYD Company Limited BYD400MIK-36's 10.29 A short-circuit current by 1.56 equals 16.05 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can BYD Company Limited BYD400MIK-36 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.76 V cold Voc at 14 F and handles 10.29 A Isc; string inverters cap BYD Company Limited BYD400MIK-36 at 11 panels on 600 V.

### Is BYD Company Limited BYD400MIK-36 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of BYD Company Limited BYD400MIK-36 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

## Related Pages

Compare BYD Company Limited equipment, AXITEC AC-410MB/144V specs, utility payback rates, and NEC string calculators alongside BYD Company Limited BYD400MIK-36.

[All BYD Company Limited Certified Solar Models](https://epri-peac.com/solar-equipment/brands/byd-company-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From BYD Company Limited

- [All BYD Company Limited Specs](https://epri-peac.com/solar-equipment/brands/byd-company-limited/)
- [BYD Company Limited BYD660MSTK-33](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd660mstk-33/)
- [BYD Company Limited BYD645MSTK-33](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd645mstk-33/)
- [BYD Company Limited BYD580NLBK-36](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd580nlbk-36/)
- [BYD Company Limited BYD565NLBK-36](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd565nlbk-36/)
- [BYD Company Limited BYD555MLTK-36](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd555mltk-36/)