BLUESUN GROUP LIMITED BSM605M10-72HNH is a 605.0 W STC (575.1 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 23.45% efficiency, 52.9 V Voc at 25 C, and 56.94 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 605.0 W

- **PTC Wattage** : 575.1 W

- **Voc @ 25C** : 52.9 V

- **Efficiency** : 23.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does BLUESUN GROUP LIMITED BSM605M10-72HNH Compare Against Peer CEC Listings?

How BLUESUN GROUP LIMITED BLUESUN GROUP LIMITED BSM605M10-72HNH handles rooftop heat (575.1 W PTC), 8 kW sizing, and cold winter string voltage.

BLUESUN GROUP LIMITED builds the BLUESUN GROUP LIMITED BSM605M10-72HNH (Mono-c-Si) as a large-format commercial and ground-mount module delivering 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-144-BFN10-605W-DG (605.0 W), this model holds strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Higher 52.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.92 A overcurrent floor served by a 25 A breaker.

## Where Does BLUESUN GROUP LIMITED BSM605M10-72HNH Fall Across Listed CEC Models?

Where BLUESUN GROUP LIMITED BSM605M10-72HNH (605.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define BLUESUN GROUP LIMITED BSM605M10-72HNH?

Percentile placement of BLUESUN GROUP LIMITED BSM605M10-72HNH across power density (234.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for BLUESUN GROUP LIMITED BSM605M10-72HNH?

Four critical engineering numbers homeowners and solar installers check first when reviewing BLUESUN GROUP LIMITED BSM605M10-72HNH specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #1,214 / 21,677

### Top 6.1% STC Output

605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #560

### 23.45% Aperture Efficiency

Power density 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.94 V at -10 C (569.4 V string) and 58.09 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,470 W STC

Occupies 36.1 m2 (389 sq ft) producing 8,051 W PTC; NEC 690.8 OCPD floor is 21.92 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.9 * (1 + (-0.218/100) * (-10 - 25)) = 56.94 V | OCPD = 1.56 * 14.05 = 21.92 A

Inputs from CEC Modules.csv for BLUESUN GROUP LIMITED BSM605M10-72HNH: Voc=52.9 V, beta_Voc=-0.218%/C, Isc=14.05 A, STC=605.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (569.4 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for BLUESUN GROUP LIMITED BSM605M10-72HNH?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for BLUESUN GROUP LIMITED BSM605M10-72HNH.

Official California Energy Commission (NREL SAM) test parameters for BLUESUN GROUP LIMITED BSM605M10-72HNH.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 605.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 575.1 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 44.9 V / 13.47 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.218 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.45% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many BLUESUN GROUP LIMITED BSM605M10-72HNH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using BLUESUN GROUP LIMITED BSM605M10-72HNH (605.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.05 kW | 278 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 14 | 8.47 kW | 389 sq ft | $2,120 | $3,585 |
| **10 kW Class** | 17 | 10.29 kW | 472 sq ft | $2,575 | $4,355 |

## Which Sibling Wattage & Trim Variants Belong to This BLUESUN GROUP LIMITED Series?

All closely matched BLUESUN GROUP LIMITED wattages and cosmetic trims sharing the BLUESUN GROUP LIMITED BSM605M10-72HNH architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the BLUESUN GROUP LIMITED BSM605M10-72HNH wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **BLUESUN GROUP LIMITED BSM600M10-72HNH** | 600.0 W | 570.2 W | 52.7 V | 44.8 V | 23.26% |
| **BLUESUN GROUP LIMITED BSM605M10-72HNH** | 605.0 W | 575.1 W | 52.9 V | 44.9 V | 23.45% |
| **BLUESUN GROUP LIMITED BSM610M10-72HNH** | 610.0 W | 579.9 W | 53.1 V | 45.1 V | 23.64% |

## How Many BLUESUN GROUP LIMITED BSM605M10-72HNH Modules Fit in a Cold-Weather String?

Maximum series module counts for BLUESUN GROUP LIMITED BSM605M10-72HNH from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.9V and beta_Voc=-0.218%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.09 V | 10 panels | 580.9 V | 17 panels |
| **-10 C (14 F)** | 56.94 V | 10 panels | 569.4 V | 17 panels |
| **0 C (32 F)** | 55.78 V | 10 panels | 557.8 V | 17 panels |
| **25 C (77 F STC)** | 52.9 V | 11 panels | 581.9 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to BLUESUN GROUP LIMITED BSM605M10-72HNH?

Alternative CEC solar modules from competing brands near BLUESUN GROUP LIMITED BSM605M10-72HNH (605.0 W), including Aptos Solar Technology LLC DNA-144-BFN10-605W-DG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-144-BFN10-605W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bfn10-605w-dg/) Aptos Solar Technology LLC | 605.0 W | Tie (0 W) | 52.9 V | 23.45% | 95.1% |
| [**JA Solar JAM78D30-605/MB**](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/) JA Solar | 605.0 W | Tie (0 W) | 53.61 V | 22.24% | 93.8% |
| [**LONGi Green Energy Technology Co Ltd LR5-78HBD-605M**](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-78hbd-605m/) LONGi Green Energy Technology Co Ltd | 605.0 W | Tie (0 W) | 54.2 V | 22.24% | 94.5% |
| [**CSI Solar Co Ltd CS6W-600TB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6w-600tb-ag/) CSI Solar Co Ltd | 600.0 W | -5.0 W | 53.0 V | 23.9% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for BLUESUN GROUP LIMITED BSM605M10-72HNH?

Evaluate BLUESUN GROUP LIMITED BSM605M10-72HNH (605.0 W STC, 52.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), BLUESUN GROUP LIMITED BSM605M10-72HNH reaches 58.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of BLUESUN GROUP LIMITED BSM605M10-72HNH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### BLUESUN GROUP LIMITED BSM605M10-72HNH 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BFN10-605W-DG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 575.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for BLUESUN GROUP LIMITED BSM605M10-72HNH by BLUESUN GROUP LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for BLUESUN GROUP LIMITED BSM605M10-72HNH?

Multiplying BLUESUN GROUP LIMITED BSM605M10-72HNH's 14.05 A short-circuit current by 1.56 equals 21.92 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can BLUESUN GROUP LIMITED BSM605M10-72HNH pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 56.94 V cold Voc at 14 F and handles 14.05 A Isc; string inverters cap BLUESUN GROUP LIMITED BSM605M10-72HNH at 10 panels on 600 V.

### Is BLUESUN GROUP LIMITED BSM605M10-72HNH eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of BLUESUN GROUP LIMITED BSM605M10-72HNH rely on utility bill offset (~$2,120/yr at 8 kW) rather than 25D.

## Related Pages

Compare BLUESUN GROUP LIMITED equipment, Aptos Solar Technology LLC DNA-144-BFN10-605W-DG specs, utility payback rates, and NEC string calculators alongside BLUESUN GROUP LIMITED BSM605M10-72HNH.

[All BLUESUN GROUP LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/bluesun-group-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From BLUESUN GROUP LIMITED

- [All BLUESUN GROUP LIMITED Specs](https://epri-peac.com/solar-equipment/brands/bluesun-group-limited/)
- [BLUESUN GROUP LIMITED BSM590M10-72HNH](https://epri-peac.com/solar-equipment/modules/bluesun-group-limited/bluesun-group-limited-bsm590m10-72hnh/)
- [BLUESUN GROUP LIMITED BSM565M10-72HBD](https://epri-peac.com/solar-equipment/modules/bluesun-group-limited/bluesun-group-limited-bsm565m10-72hbd/)