title: "Bila Solar Inc AA520US-6x24GG Specs (520.0W, 49.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-aa520us-6x24gg/
description: "CEC datasheet for Bila Solar Inc AA520US-6x24GG: 520.0W STC, 49.0V Voc, 16-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Bila Solar Inc AA520US-6x24GG — CEC Solar Module Specifications

Manufacturer: [**Bila Solar Inc**](https://epri-peac.com/solar-equipment/brands/bila-solar-inc/) Registry: **CEC Verified Engineering Specification**

Bila Solar Inc AA520US-6x24GG is a 520.0 W STC (482.1 W PTC) Mono-c-Si solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 20.72% efficiency, 49.0 V Voc at 25 C, and 53.34 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 520.0 W

- **PTC Wattage** : 482.1 W

- **Voc @ 25C** : 49.0 V

- **Efficiency** : 20.72%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Bila Solar Inc AA520US-6x24GG Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Bila Solar Inc AA520US-6x24GG (Mono-c-Si) residential solar systems.

Homeowners evaluating Bila Solar Inc AA520US-6x24GG need 12 panels for 6 kW or 16 panels (432 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 16 panels (432 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.253%/C) pushes open-circuit voltage to 53.34 V at 14 F and 54.58 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does Bila Solar Inc AA520US-6x24GG Fall Across Listed CEC Models?

Comparison of Bila Solar Inc AA520US-6x24GG (520.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Bila Solar Inc AA520US-6x24GG?

Relative ranking of Bila Solar Inc AA520US-6x24GG across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Bila Solar Inc AA520US-6x24GG?

Summary of Bila Solar Inc AA520US-6x24GG output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.

Rank #4,199 / 21,677

### Top 19.9% STC Output

520.0 W STC (+135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,646

### 20.72% Aperture Efficiency

Power density 207.2 W/m2 (0.81 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.34 V at -10 C (586.7 V string) and 54.58 V at -20 C (10 max).

 8 kW Reference Array

### 16 Panels = 8,320 W STC

Occupies 40.2 m2 (432 sq ft) producing 7,714 W PTC; NEC 690.8 OCPD floor is 21.18 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.253/100) * (-10 - 25)) = 53.34 V | OCPD = 1.56 * 13.58 = 21.18 A

Inputs from CEC Modules.csv for Bila Solar Inc AA520US-6x24GG: Voc=49.0 V, beta_Voc=-0.253%/C, Isc=13.58 A, STC=520.0 W, Area=2.51 m2.

**Result:** 11 panels max on 600 V (586.7 V); 16 panels for 8 kW (432 sq ft).

## What Are the Published CEC Specifications for Bila Solar Inc AA520US-6x24GG?

Complete CEC test sheet for Bila Solar Inc AA520US-6x24GG including Isc (13.58 A), Voc (49.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Bila Solar Inc AA520US-6x24GG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 520.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 482.1 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.99 V / 12.69 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.253 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.72% (2.51 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Bila Solar Inc AA520US-6x24GG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Bila Solar Inc AA520US-6x24GG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.24 kW | 324 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 16 | 8.32 kW | 432 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 20 | 10.4 kW | 540 sq ft | $2,603 | $4,402 |

## How Many Bila Solar Inc AA520US-6x24GG Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Bila Solar Inc AA520US-6x24GG (49.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.0V and beta_Voc=-0.253%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.58 V | 10 panels | 545.8 V | 18 panels |
| **-10 C (14 F)** | 53.34 V | 11 panels | 586.7 V | 18 panels |
| **0 C (32 F)** | 52.1 V | 11 panels | 573.1 V | 19 panels |
| **25 C (77 F STC)** | 49.0 V | 12 panels | 588.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Bila Solar Inc AA520US-6x24GG?

Four comparable CEC modules such as HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI (520.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI**](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/) HYUNDAI ENERGY SOLUTIONS CO LTD | 520.0 W | Tie (0 W) | 49.0 V | 20.23% | 93.9% |
| [**ES Foundry Corp ES-DP8-H72L-520W**](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72l-520w/) ES Foundry Corp | 520.0 W | Tie (0 W) | 48.9 V | 20.88% | 93.2% |
| [**Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520**](https://epri-peac.com/solar-equipment/modules/jiangsu-green-energy-power-technology-co-ltd/jiangsu-green-energy-power-technology-co-ltd-geo-pm10-72d520/) Jiangsu Green Energy Power Technology Co Ltd | 520.0 W | Tie (0 W) | 48.9 V | 20.63% | 93.8% |
| [**Heliene 144HC-520 M10 SL Bifacial**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-520-m10-sl-bifacial/) Heliene | 520.0 W | Tie (0 W) | 49.22 V | 20.16% | 94.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Bila Solar Inc AA520US-6x24GG?

Evaluate Bila Solar Inc AA520US-6x24GG (520.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Bila Solar Inc AA520US-6x24GG reaches 54.58 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 432 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (432 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Bila Solar Inc AA520US-6x24GG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Bila Solar Inc AA520US-6x24GG 8 kW Residential Fit

Needs 16 modules (432 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 482.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Bila Solar Inc AA520US-6x24GG by Bila Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Bila Solar Inc AA520US-6x24GG PTC wattage (482.1 W) lower than STC (520.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 482.1 W PTC (92.7% retention) across Bila Solar Inc AA520US-6x24GG's 2.51 m2 aperture.

### Who should skip Bila Solar Inc AA520US-6x24GG on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 Bila Solar Inc AA520US-6x24GG panels (432 sq ft) leave unusable roof gaps vs. HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI.

### What is the 1,000 V commercial string limit for Bila Solar Inc AA520US-6x24GG?

On 1,000 V commercial inverters at -10 C (53.34 V cold Voc), Bila Solar Inc AA520US-6x24GG fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Bila Solar Inc AA520US-6x24GG.

## Related Pages

Compare Bila Solar Inc equipment, HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI specs, utility payback rates, and NEC string calculators alongside Bila Solar Inc AA520US-6x24GG.

[All Bila Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/bila-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Bila Solar Inc

- [All Bila Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/bila-solar-inc/)
- [Bila Solar Inc AA560US-6x24GG](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-aa560us-6x24gg/)
- [Bila Solar Inc AA535US-6x24GG](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-aa535us-6x24gg/)
- [Bila Solar Inc BF530J-12X12UW](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-bf530j-12x12uw/)
- [Bila Solar Inc DF530J-12X12UW](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-df530j-12x12uw/)
- [Bila Solar Inc BF510J-12X12UW](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-bf510j-12x12uw/)