Belinus Solar BV BE-M7-GG-108-395 is a 395.0 W STC (370.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 37.03 V Voc at 25 C, and 40.36 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 370.4 W

- **Voc @ 25C** : 37.03 V

- **Efficiency** : 20.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Belinus Solar BV BE-M7-GG-108-395 Compare Against Peer CEC Listings?

How Belinus Solar BV Belinus Solar BV BE-M7-GG-108-395 handles rooftop heat (370.4 W PTC), 8 kW sizing, and cold winter string voltage.

Belinus Solar BV builds the Belinus Solar BV BE-M7-GG-108-395 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM54M-HC-BF-395 (395.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Lower 37.03 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.2 A overcurrent floor served by a 25 A breaker.

## Where Does Belinus Solar BV BE-M7-GG-108-395 Fall Across Listed CEC Models?

Where Belinus Solar BV BE-M7-GG-108-395 (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Belinus Solar BV BE-M7-GG-108-395?

Percentile placement of Belinus Solar BV BE-M7-GG-108-395 across power density (202.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Belinus Solar BV BE-M7-GG-108-395?

Four critical engineering numbers homeowners and solar installers check first when reviewing Belinus Solar BV BE-M7-GG-108-395 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,479

### 20.26% Aperture Efficiency

Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.36 V at -10 C (565.0 V string) and 41.31 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,778 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.03 * (1 + (-0.257/100) * (-10 - 25)) = 40.36 V | OCPD = 1.56 * 13.59 = 21.2 A

Inputs from CEC Modules.csv for Belinus Solar BV BE-M7-GG-108-395: Voc=37.03 V, beta_Voc=-0.257%/C, Isc=13.59 A, STC=395.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (565.0 V); 21 panels for 8 kW (441 sq ft).

## What Are the Published CEC Specifications for Belinus Solar BV BE-M7-GG-108-395?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Belinus Solar BV BE-M7-GG-108-395.

Official California Energy Commission (NREL SAM) test parameters for Belinus Solar BV BE-M7-GG-108-395.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 370.4 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.0 V / 12.75 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.257 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.26% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Belinus Solar BV BE-M7-GG-108-395 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Belinus Solar BV BE-M7-GG-108-395 (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |

## Which Sibling Wattage & Trim Variants Belong to This Belinus Solar BV Series?

All closely matched Belinus Solar BV wattages and cosmetic trims sharing the Belinus Solar BV BE-M7-GG-108-395 architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Belinus Solar BV BE-M7-GG-108-395 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Belinus Solar BV BE-M7-GG-108-390** | 390.0 W | 365.6 W | 36.84 V | 30.82 V | 20.0% |
| **Belinus Solar BV BE-M7-GG-108-395** | 395.0 W | 370.4 W | 37.03 V | 31.0 V | 20.26% |

## How Many Belinus Solar BV BE-M7-GG-108-395 Modules Fit in a Cold-Weather String?

Maximum series module counts for Belinus Solar BV BE-M7-GG-108-395 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.03V and beta_Voc=-0.257%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.31 V | 14 panels | 578.3 V | 24 panels |
| **-10 C (14 F)** | 40.36 V | 14 panels | 565.0 V | 24 panels |
| **0 C (32 F)** | 39.41 V | 15 panels | 591.1 V | 25 panels |
| **25 C (77 F STC)** | 37.03 V | 16 panels | 592.5 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Belinus Solar BV BE-M7-GG-108-395?

Alternative CEC solar modules from competing brands near Belinus Solar BV BE-M7-GG-108-395 (395.0 W), including Elin Energy (Sirius PV) ELNSM54M-HC-BF-395.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Elin Energy (Sirius PV) ELNSM54M-HC-BF-395**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-bf-395/) Elin Energy (Sirius PV) | 395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.3% |
| [**AXITEC AC-395MBT/108V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-395mbt-108v/) AXITEC | 395.0 W | Tie (0 W) | 37.0 V | 20.47% | 93.3% |
| [**ASTORIOS Holding Inc ASTR108BDG-395W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr108bdg-395w-us/) ASTORIOS Holding Inc | 395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.9% |
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108BS**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae390md-108bs/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 390.0 W | -5.0 W | 36.9 V | 20.21% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Belinus Solar BV BE-M7-GG-108-395?

Evaluate Belinus Solar BV BE-M7-GG-108-395 (395.0 W STC, 37.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Belinus Solar BV BE-M7-GG-108-395 reaches 41.31 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Belinus Solar BV BE-M7-GG-108-395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Belinus Solar BV BE-M7-GG-108-395 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-BF-395.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 370.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Belinus Solar BV BE-M7-GG-108-395 by Belinus Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Belinus Solar BV BE-M7-GG-108-395?

Multiplying Belinus Solar BV BE-M7-GG-108-395's 13.59 A short-circuit current by 1.56 equals 21.2 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Belinus Solar BV BE-M7-GG-108-395 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.36 V cold Voc at 14 F and handles 13.59 A Isc; string inverters cap Belinus Solar BV BE-M7-GG-108-395 at 14 panels on 600 V.

### Is Belinus Solar BV BE-M7-GG-108-395 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Belinus Solar BV BE-M7-GG-108-395 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

## Related Pages

Compare Belinus Solar BV equipment, Elin Energy (Sirius PV) ELNSM54M-HC-BF-395 specs, utility payback rates, and NEC string calculators alongside Belinus Solar BV BE-M7-GG-108-395.

[All Belinus Solar BV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/belinus-solar-bv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Belinus Solar BV

- [All Belinus Solar BV Specs](https://epri-peac.com/solar-equipment/brands/belinus-solar-bv/)
- [Belinus Solar BV BE-M7-GG-108-405](https://epri-peac.com/solar-equipment/modules/belinus-solar-bv/belinus-solar-bv-be-m7-gg-108-405/)