CEC PV Module

# AXITEC AC-590TGB/144TS — CEC Solar Module Specifications

Manufacturer: [**AXITEC**](https://epri-peac.com/solar-equipment/brands/axitec/) Registry: **CEC Verified Engineering Specification**

AXITEC AC-590TGB/144TS is a 590.0 W STC (561.0 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 23.41% efficiency, 51.7 V Voc at 25 C, and 56.24 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 590.0 W

- **PTC Wattage** : 561.0 W

- **Voc @ 25C** : 51.7 V

- **Efficiency** : 23.41%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does AXITEC AC-590TGB/144TS Compare Against Peer CEC Listings?

Engineering position of AXITEC AC-590TGB/144TS (590.0 W STC) vs. Bluesun Solar CoLtd BSM590M10-72HNH across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, AXITEC AC-590TGB/144TS pairs strong 95.1% PTC-to-STC heat retention (#713 of 21,677) with 51.7 V nominal Voc. An 8 kW residential build (8,260 W DC, 7,854 W PTC) saves ~$2,067/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Bluesun Solar CoLtd BSM590M10-72HNH offers a 590.0 W alternative.

## Where Does AXITEC AC-590TGB/144TS Fall Across Listed CEC Models?

Plots AXITEC AC-590TGB/144TS at 590.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define AXITEC AC-590TGB/144TS?

Benchmarks AXITEC AC-590TGB/144TS on STC wattage, thermal PTC/STC retention, and 23.41 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for AXITEC AC-590TGB/144TS?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-590TGB/144TS by AXITEC.

Rank #1,597 / 21,677

### Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #626

### 23.41% Aperture Efficiency

Power density 234.1 W/m2 (3.50 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.24 V at -10 C (562.4 V string) and 57.54 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,260 W STC

Occupies 35.3 m2 (380 sq ft) producing 7,854 W PTC; NEC 690.8 OCPD floor is 22.59 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.7 * (1 + (-0.251/100) * (-10 - 25)) = 56.24 V | OCPD = 1.56 * 14.48 = 22.59 A

Inputs from CEC Modules.csv for AXITEC AC-590TGB/144TS: Voc=51.7 V, beta_Voc=-0.251%/C, Isc=14.48 A, STC=590.0 W, Area=2.52 m2.

**Result:** 10 panels max on 600 V (562.4 V); 14 panels for 8 kW (380 sq ft).

## What Are the Published CEC Specifications for AXITEC AC-590TGB/144TS?

Laboratory test ratings recorded for AXITEC AC-590TGB/144TS (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-590TGB/144TS.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 590.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 561.0 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 51.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.87 V / 13.77 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.251 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.41% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many AXITEC AC-590TGB/144TS Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (380 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-590TGB/144TS.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.49 kW | 298 sq ft | $1,624 | $2,747 |
| **8 kW Class** | 14 | 8.26 kW | 380 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 17 | 10.03 kW | 461 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Sibling wattage bins and frame colors grouped with AXITEC AC-590TGB/144TS under AXITEC to prevent duplicate spec pages.

Sibling CEC listings grouped into the AXITEC AC-590TGB/144TS wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **AXITEC AC-575TGB/144TS** | 575.0 W | 546.4 W | 51.28 V | 42.41 V | 22.82% |
| **AXITEC AC-580TGB/144TS** | 580.0 W | 551.3 W | 51.43 V | 42.56 V | 23.02% |
| **AXITEC AC-585TGB/144TS** | 585.0 W | 556.2 W | 51.58 V | 42.72 V | 23.21% |
| **AXITEC AC-590TGB/144TS** | 590.0 W | 561.0 W | 51.7 V | 42.87 V | 23.41% |

## How Many AXITEC AC-590TGB/144TS Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for AXITEC AC-590TGB/144TS (beta_Voc -0.251%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=51.7V and beta_Voc=-0.251%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 57.54 V | 10 panels | 575.4 V | 17 panels |
| **-10 C (14 F)** | 56.24 V | 10 panels | 562.4 V | 17 panels |
| **0 C (32 F)** | 54.94 V | 10 panels | 549.4 V | 18 panels |
| **25 C (77 F STC)** | 51.7 V | 11 panels | 568.7 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-590TGB/144TS?

Closest cross-brand CEC competitors to AXITEC AC-590TGB/144TS matched near 590.0 W STC and 51.7 V Voc, led by Bluesun Solar CoLtd BSM590M10-72HNH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Bluesun Solar CoLtd BSM590M10-72HNH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm590m10-72hnh/) Bluesun Solar CoLtd | 590.0 W | Tie (0 W) | 51.3 V | 23.05% | 95.2% |
| [**AE Solar GmbH AE585CMD-144BDS**](https://epri-peac.com/solar-equipment/modules/ae-solar-gmbh/ae-solar-gmbh-ae585cmd-144bds/) AE Solar GmbH | 585.0 W | -5.0 W | 51.6 V | 22.67% | 95.3% |
| [**DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW**](https://epri-peac.com/solar-equipment/modules/de-solar-s-pte-ltd/de-solar-s-pte-ltd-de585-144bg-182s-n-ww/) DE SOLAR(S) PTE LTD | 585.0 W | -5.0 W | 51.6 V | 22.67% | 95.3% |
| [**Chint New Energy Technology Co Ltd CHSM72N-HC-585**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72n-hc-585/) Chint New Energy Technology Co Ltd | 585.0 W | -5.0 W | 51.3 V | 22.67% | 94.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for AXITEC AC-590TGB/144TS?

Evaluate AXITEC AC-590TGB/144TS (590.0 W STC, 51.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-590TGB/144TS reaches 57.54 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 380 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-590TGB/144TS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### AXITEC AC-590TGB/144TS 8 kW Residential Fit

Needs 14 modules (380 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM590M10-72HNH.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 561.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-590TGB/144TS by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for AXITEC AC-590TGB/144TS?

Multiplying AXITEC AC-590TGB/144TS's 14.48 A short-circuit current by 1.56 equals 22.59 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can AXITEC AC-590TGB/144TS pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 56.24 V cold Voc at 14 F and handles 14.48 A Isc; string inverters cap AXITEC AC-590TGB/144TS at 10 panels on 600 V.

### Is AXITEC AC-590TGB/144TS eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-590TGB/144TS rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

## Related Pages

Compare AXITEC equipment, Bluesun Solar CoLtd BSM590M10-72HNH specs, utility payback rates, and NEC string calculators alongside AXITEC AC-590TGB/144TS.

[All AXITEC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/axitec/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From AXITEC

- [All AXITEC Specs](https://epri-peac.com/solar-equipment/brands/axitec/)
- [AXITEC AC-565TGB/144TS](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-565tgb-144ts/)
- [AXITEC AC-555MBT/144US](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144us/)
- [AXITEC AC-555MBT/144V](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144v/)
- [AXITEC AC-555MBT/144VB](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144vb/)
- [AXITEC AC-555MH/144V](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mh-144v/)