# AXITEC AC-190M/125-72S — CEC Solar Module Specifications

Manufacturer: [**AXITEC**](https://epri-peac.com/solar-equipment/brands/axitec/) Registry: **CEC Verified Engineering Specification**

AXITEC AC-190M/125-72S is a 190.0 W STC (170.6 W PTC) Mono-c-Si solar module ranking #21,132 of 21,677 CEC listings (below all-CEC median; higher than 2.3% of peers). It delivers 14.88% efficiency, 45.23 V Voc at 25 C, and 51.61 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 190.0 W

- **PTC Wattage** : 170.6 W

- **Voc @ 25C** : 45.23 V

- **Efficiency** : 14.88%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does AXITEC AC-190M/125-72S Compare Against Peer CEC Listings?

How AXITEC AXITEC AC-190M/125-72S handles rooftop heat (170.6 W PTC), 8 kW sizing, and cold winter string voltage.

AXITEC builds the AXITEC AC-190M/125-72S (Mono-c-Si) as a compact residential or specialty off-grid module delivering 148.8 W/m2 (5.03 percentage points below 19.91% CEC median). Compared against Suntech Power STP190S-24/Ad (190.0 W), this model holds typical 89.8% PTC-to-STC thermal output (170.6 W real-world rating). Mid-range 45.23 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.6 A overcurrent floor served by a 15 A breaker.

## Where Does AXITEC AC-190M/125-72S Fall Across Listed CEC Models?

Where AXITEC AC-190M/125-72S (190.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define AXITEC AC-190M/125-72S?

Percentile placement of AXITEC AC-190M/125-72S across power density (148.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for AXITEC AC-190M/125-72S?

Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-190M/125-72S specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #21,132 / 21,677

### 190.0 W STC · Higher Than 2.3%

190.0 W STC (-195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,900

### 14.88% Aperture Efficiency

Power density 148.8 W/m2 (5.03 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.61 V at -10 C (567.7 V string) and 53.43 V at -20 C (11 max).

 8 kW Reference Array

### 43 Panels = 8,170 W STC

Occupies 54.9 m2 (591 sq ft) producing 7,336 W PTC; NEC 690.8 OCPD floor is 8.6 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.23 * (1 + (-0.403/100) * (-10 - 25)) = 51.61 V | OCPD = 1.56 * 5.51 = 8.6 A

Inputs from CEC Modules.csv for AXITEC AC-190M/125-72S: Voc=45.23 V, beta_Voc=-0.403%/C, Isc=5.51 A, STC=190.0 W, Area=1.277 m2.

**Result:** 11 panels max on 600 V (567.7 V); 43 panels for 8 kW (591 sq ft).

## What Are the Published CEC Specifications for AXITEC AC-190M/125-72S?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-190M/125-72S.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-190M/125-72S.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 190.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 170.6 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.23 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 5.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.5 V / 5.21 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.403 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.88% (1.277 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many AXITEC AC-190M/125-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-190M/125-72S (190.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 32 | 6.08 kW | 440 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 43 | 8.17 kW | 591 sq ft | $2,045 | $3,458 |
| **10 kW Class** | 53 | 10.07 kW | 729 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-190M/125-72S architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the AXITEC AC-190M/125-72S wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **AXITEC AC-190M/125-72S** | 190.0 W | 170.6 W | 45.23 V | 36.5 V | 14.88% |
| **AXITEC AC-195M/125-72S** | 195.0 W | 175.2 W | 45.44 V | 36.94 V | 15.27% |

## How Many AXITEC AC-190M/125-72S Modules Fit in a Cold-Weather String?

Maximum series module counts for AXITEC AC-190M/125-72S from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.23V and beta_Voc=-0.403%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.43 V | 11 panels | 587.7 V | 18 panels |
| **-10 C (14 F)** | 51.61 V | 11 panels | 567.7 V | 19 panels |
| **0 C (32 F)** | 49.79 V | 12 panels | 597.5 V | 20 panels |
| **25 C (77 F STC)** | 45.23 V | 13 panels | 588.0 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-190M/125-72S?

Alternative CEC solar modules from competing brands near AXITEC AC-190M/125-72S (190.0 W), including Suntech Power STP190S-24/Ad.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Suntech Power STP190S-24/Ad**](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp190s-24-ad/) Suntech Power | 190.0 W | Tie (0 W) | 45.2 V | 14.88% | 90.3% |
| [**Suntech Power STP190S-24/Adb**](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp190s-24-adb/) Suntech Power | 190.0 W | Tie (0 W) | 45.2 V | 14.88% | 90.4% |
| [**Seraphim Solar System CoLtd SRP-190-5MB**](https://epri-peac.com/solar-equipment/modules/seraphim-solar-system-coltd/seraphim-solar-system-coltd-srp-190-5mb/) Seraphim Solar System CoLtd | 190.0 W | Tie (0 W) | 45.1 V | 14.88% | 90.3% |
| [**Trina Solar TSM-190DA01A**](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-190da01a/) Trina Solar | 190.0 W | Tie (0 W) | 45.1 V | 15.05% | 90.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for AXITEC AC-190M/125-72S?

Evaluate AXITEC AC-190M/125-72S (190.0 W STC, 45.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-190M/125-72S reaches 53.43 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 43 panels for an 8 kW build require 591 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 43 panels (591 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-190M/125-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### AXITEC AC-190M/125-72S 8 kW Residential Fit

Needs 43 modules (591 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Suntech Power STP190S-24/Ad.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 170.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-190M/125-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for AXITEC AC-190M/125-72S?

Multiplying AXITEC AC-190M/125-72S's 5.51 A short-circuit current by 1.56 equals 8.6 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can AXITEC AC-190M/125-72S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.61 V cold Voc at 14 F and handles 5.51 A Isc; string inverters cap AXITEC AC-190M/125-72S at 11 panels on 600 V.

### Is AXITEC AC-190M/125-72S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-190M/125-72S rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

## Related Pages

Compare AXITEC equipment, Suntech Power STP190S-24/Ad specs, utility payback rates, and NEC string calculators alongside AXITEC AC-190M/125-72S.

[All AXITEC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/axitec/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From AXITEC

- [All AXITEC Specs](https://epri-peac.com/solar-equipment/brands/axitec/)
- [AXITEC AC-590TGB/144TS](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/)
- [AXITEC AC-565TGB/144TS](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-565tgb-144ts/)
- [AXITEC AC-555MBT/144US](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144us/)
- [AXITEC AC-555MBT/144V](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144v/)
- [AXITEC AC-555MBT/144VB](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144vb/)