title: "Auxin Solar AXNG1M395W Specs (395.0W, 48.33V Voc)"
url: https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m395w/
description: "CEC datasheet for Auxin Solar AXNG1M395W: 395.0W STC, 48.33V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Auxin Solar AXNG1M395W — CEC Solar Module Specifications

Manufacturer: [**Auxin Solar**](https://epri-peac.com/solar-equipment/brands/auxin-solar/) Registry: **CEC Verified Engineering Specification**

Auxin Solar AXNG1M395W is a 395.0 W STC (368.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.15% efficiency, 48.33 V Voc at 25 C, and 52.8 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 368.1 W

- **Voc @ 25C** : 48.33 V

- **Efficiency** : 20.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Auxin Solar AXNG1M395W Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXNG1M395W (395.0 W STC) vs. Aptos Solar Technology LLC DNA-144-MF23-395W {Blk} across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Auxin Solar AXNG1M395W pairs strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677) with 48.33 V nominal Voc. An 8 kW residential build (8,295 W DC, 7,730 W PTC) saves ~$2,075/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Aptos Solar Technology LLC DNA-144-MF23-395W {Blk} offers a 395.0 W alternative.

## Where Does Auxin Solar AXNG1M395W Fall Across Listed CEC Models?

Plots Auxin Solar AXNG1M395W at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Auxin Solar AXNG1M395W?

Benchmarks Auxin Solar AXNG1M395W on STC wattage, thermal PTC/STC retention, and 20.15 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Auxin Solar AXNG1M395W?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXNG1M395W by Auxin Solar.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,939

### 20.15% Aperture Efficiency

Power density 201.5 W/m2 (0.24 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.8 V at -10 C (580.8 V string) and 54.07 V at -20 C (11 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 41.2 m2 (443 sq ft) producing 7,730 W PTC; NEC 690.8 OCPD floor is 15.97 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.33 * (1 + (-0.264/100) * (-10 - 25)) = 52.8 V | OCPD = 1.56 * 10.24 = 15.97 A

Inputs from CEC Modules.csv for Auxin Solar AXNG1M395W: Voc=48.33 V, beta_Voc=-0.264%/C, Isc=10.24 A, STC=395.0 W, Area=1.96 m2.

**Result:** 11 panels max on 600 V (580.8 V); 21 panels for 8 kW (443 sq ft).

## What Are the Published CEC Specifications for Auxin Solar AXNG1M395W?

Laboratory test ratings recorded for Auxin Solar AXNG1M395W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXNG1M395W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 368.1 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.33 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.13 V / 9.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.264 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.15% (1.96 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Auxin Solar AXNG1M395W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (443 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXNG1M395W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 338 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 443 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 549 sq ft | $2,570 | $4,347 |

## Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Sibling wattage bins and frame colors grouped with Auxin Solar AXNG1M395W under Auxin Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Auxin Solar AXNG1M395W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Auxin Solar AXNG1M390W** | 390.0 W | 363.3 W | 47.9 V | 40.07 V | 19.9% |
| **Auxin Solar AXNG1M395W** | 395.0 W | 368.1 W | 48.33 V | 41.13 V | 20.15% |

## How Many Auxin Solar AXNG1M395W Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXNG1M395W (beta_Voc -0.264%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=48.33V and beta_Voc=-0.264%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.07 V | 11 panels | 594.8 V | 18 panels |
| **-10 C (14 F)** | 52.8 V | 11 panels | 580.8 V | 18 panels |
| **0 C (32 F)** | 51.52 V | 11 panels | 566.7 V | 19 panels |
| **25 C (77 F STC)** | 48.33 V | 12 panels | 580.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXNG1M395W?

Closest cross-brand CEC competitors to Auxin Solar AXNG1M395W matched near 395.0 W STC and 48.33 V Voc, led by Aptos Solar Technology LLC DNA-144-MF23-395W {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-144-MF23-395W {Blk}**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-mf23-395w-blk/) Aptos Solar Technology LLC | 395.0 W | Tie (0 W) | 48.37 V | 19.63% | 90.7% |
| [**Aptos Solar Technology LLC DNA-144-MF23-395W {Wht}**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-mf23-395w-wht/) Aptos Solar Technology LLC | 395.0 W | Tie (0 W) | 48.37 V | 20.26% | 93.4% |
| [**CertainTeed CT395HC00-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct395hc00-04/) CertainTeed | 395.0 W | Tie (0 W) | 48.37 V | 20.26% | 93.4% |
| [**CertainTeed CT395HC11-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct395hc11-04/) CertainTeed | 395.0 W | Tie (0 W) | 48.37 V | 20.26% | 90.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Auxin Solar AXNG1M395W?

Evaluate Auxin Solar AXNG1M395W (395.0 W STC, 48.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXNG1M395W reaches 54.07 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (443 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXNG1M395W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Auxin Solar AXNG1M395W 8 kW Residential Fit

Needs 21 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF23-395W {Blk}.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXNG1M395W by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Auxin Solar AXNG1M395W?

Multiplying Auxin Solar AXNG1M395W's 10.24 A short-circuit current by 1.56 equals 15.97 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Auxin Solar AXNG1M395W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.8 V cold Voc at 14 F and handles 10.24 A Isc; string inverters cap Auxin Solar AXNG1M395W at 11 panels on 600 V.

### Is Auxin Solar AXNG1M395W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Auxin Solar AXNG1M395W rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

## Related Pages

Compare Auxin Solar equipment, Aptos Solar Technology LLC DNA-144-MF23-395W {Blk} specs, utility payback rates, and NEC string calculators alongside Auxin Solar AXNG1M395W.

[All Auxin Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/auxin-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Auxin Solar

- [All Auxin Solar Specs](https://epri-peac.com/solar-equipment/brands/auxin-solar/)
- [Auxin Solar AXN10M610W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m610w/)
- [Auxin Solar AXN10M585W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m585w/)
- [Auxin Solar AXN10M560W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m560w/)
- [Auxin Solar AXN10M540B](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540b/)
- [Auxin Solar AXN10M540W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540w/)