# Auxin Solar AXN10M560W — CEC Solar Module Specifications

Manufacturer: [**Auxin Solar**](https://epri-peac.com/solar-equipment/brands/auxin-solar/) Registry: **CEC Verified Engineering Specification**

Auxin Solar AXN10M560W is a 560.0 W STC (514.1 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.88% efficiency, 52.48 V Voc at 25 C, and 57.42 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 560.0 W

- **PTC Wattage** : 514.1 W

- **Voc @ 25C** : 52.48 V

- **Efficiency** : 21.88%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Auxin Solar AXN10M560W Compare Against Peer CEC Listings?

Solar engineering breakdown for Auxin Solar AXN10M560W: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Across 5,889 Mono-c-Si listings from Auxin Solar and peers, Auxin Solar AXN10M560W stands 150.0 W above the 410.0 W Mono-c-Si median and strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677). Sizing 6 kW (11 panels) to 10 kW (18 panels) yields $1,542-$2,523/yr in baseline US bill offset. Higher 52.48 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does Auxin Solar AXN10M560W Fall Across Listed CEC Models?

Distribution marker showing Auxin Solar AXN10M560W (560.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define Auxin Solar AXN10M560W?

Dataset percentiles tracking Auxin Solar AXN10M560W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Do the Dataset Ranks Show for Auxin Solar AXN10M560W?

Benchmark highlights for Auxin Solar AXN10M560W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #2,404 / 21,677

### Top 11.8% STC Output

560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,395

### 21.88% Aperture Efficiency

Power density 218.8 W/m2 (1.97 percentage points above 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.42 V at -10 C (574.2 V string) and 58.83 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,400 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,712 W PTC; NEC 690.8 OCPD floor is 20.95 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.48 * (1 + (-0.269/100) * (-10 - 25)) = 57.42 V | OCPD = 1.56 * 13.43 = 20.95 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M560W: Voc=52.48 V, beta_Voc=-0.269%/C, Isc=13.43 A, STC=560.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (574.2 V); 15 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for Auxin Solar AXN10M560W?

Official CEC datasheet figures for Auxin Solar AXN10M560W (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M560W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 514.1 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.48 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 44.14 V / 12.69 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.269 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.88% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Auxin Solar AXN10M560W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Auxin Solar AXN10M560W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.16 kW | 303 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 15 | 8.4 kW | 413 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 18 | 10.08 kW | 496 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Consolidated Auxin Solar wattage variants sharing the Auxin Solar AXN10M560W mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Auxin Solar AXN10M560W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Auxin Solar AXN10M550W** | 550.0 W | 504.6 W | 52.35 V | 44.01 V | 21.48% |
| **Auxin Solar AXN10M555W** | 555.0 W | 509.4 W | 52.42 V | 44.07 V | 21.68% |
| **Auxin Solar AXN10M560W** | 560.0 W | 514.1 W | 52.48 V | 44.14 V | 21.88% |
| **Auxin Solar AXN10M565W** | 565.0 W | 518.9 W | 52.55 V | 44.21 V | 22.07% |
| **Auxin Solar AXN10M570W** | 570.0 W | 523.6 W | 52.61 V | 44.28 V | 22.27% |

## How Many Auxin Solar AXN10M560W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Auxin Solar AXN10M560W (57.42 V at 14 F).

Computed from Voc=52.48V and beta_Voc=-0.269%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.83 V | 10 panels | 588.3 V | 16 panels |
| **-10 C (14 F)** | 57.42 V | 10 panels | 574.2 V | 17 panels |
| **0 C (32 F)** | 56.01 V | 10 panels | 560.1 V | 17 panels |
| **25 C (77 F STC)** | 52.48 V | 11 panels | 577.3 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M560W?

Competing CEC solar panels closest to Auxin Solar AXN10M560W in nameplate wattage and Voc, starting with FreeVolt ECP-PVGRAF-HC-BF560-144MT-B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**FreeVolt ECP-PVGRAF-HC-BF560-144MT-B**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-b/) FreeVolt | 560.0 W | Tie (0 W) | 52.7 V | 21.71% | 95.0% |
| [**FreeVolt ECP-PVGRAF-HC-BF560-144MT-W**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-w/) FreeVolt | 560.0 W | Tie (0 W) | 52.7 V | 21.71% | 95.0% |
| [**Boviet Solar Technology Co Ltd BVM7612M-560-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-560-h-hc/) Boviet Solar Technology Co Ltd | 560.0 W | Tie (0 W) | 51.66 V | 21.71% | 95.0% |
| [**Chint New Energy Technology Co Ltd CHSM72N-HC-560**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72n-hc-560/) Chint New Energy Technology Co Ltd | 560.0 W | Tie (0 W) | 50.55 V | 21.71% | 94.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M560W?

Evaluate Auxin Solar AXN10M560W (560.0 W STC, 52.48 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M560W reaches 58.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M560W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Auxin Solar AXN10M560W 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FreeVolt ECP-PVGRAF-HC-BF560-144MT-B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 514.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M560W by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Auxin Solar AXN10M560W?

Multiplying Auxin Solar AXN10M560W's 13.43 A short-circuit current by 1.56 equals 20.95 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Auxin Solar AXN10M560W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.42 V cold Voc at 14 F and handles 13.43 A Isc; string inverters cap Auxin Solar AXN10M560W at 10 panels on 600 V.

### Is Auxin Solar AXN10M560W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Auxin Solar AXN10M560W rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

## Related Pages

Compare Auxin Solar equipment, FreeVolt ECP-PVGRAF-HC-BF560-144MT-B specs, utility payback rates, and NEC string calculators alongside Auxin Solar AXN10M560W.

[All Auxin Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/auxin-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Auxin Solar

- [All Auxin Solar Specs](https://epri-peac.com/solar-equipment/brands/auxin-solar/)
- [Auxin Solar AXN10M610W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m610w/)
- [Auxin Solar AXN10M585W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m585w/)
- [Auxin Solar AXN10M540B](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540b/)
- [Auxin Solar AXN10M540W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540w/)
- [Auxin Solar AXN10M525W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m525w/)