title: "Auxin Solar AXN10M470W Specs (470.0W, 43.78V Voc)"
url: https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m470w/
description: "CEC datasheet for Auxin Solar AXN10M470W: 470.0W STC, 43.78V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Auxin Solar AXN10M470W — CEC Solar Module Specifications

Manufacturer: [**Auxin Solar**](https://epri-peac.com/solar-equipment/brands/auxin-solar/) Registry: **CEC Verified Engineering Specification**

Auxin Solar AXN10M470W is a 470.0 W STC (432.3 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.86% efficiency, 43.78 V Voc at 25 C, and 48.04 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 470.0 W

- **PTC Wattage** : 432.3 W

- **Voc @ 25C** : 43.78 V

- **Efficiency** : 21.86%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Auxin Solar AXN10M470W Compare Against Peer CEC Listings?

Solar engineering breakdown for Auxin Solar AXN10M470W: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Across 5,889 Mono-c-Si listings from Auxin Solar and peers, Auxin Solar AXN10M470W stands 60.0 W above the 410.0 W Mono-c-Si median and strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677). Sizing 6 kW (13 panels) to 10 kW (22 panels) yields $1,529-$2,588/yr in baseline US bill offset. Mid-range 43.78 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

## Where Does Auxin Solar AXN10M470W Fall Across Listed CEC Models?

Distribution marker showing Auxin Solar AXN10M470W (470.0 W) relative to the 385.0 W all-CEC solar panel median. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Dataset Percentiles Define Auxin Solar AXN10M470W?

Dataset percentiles tracking Auxin Solar AXN10M470W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for Auxin Solar AXN10M470W?

Benchmark highlights for Auxin Solar AXN10M470W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #4,967 / 21,677

### Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,442

### 21.86% Aperture Efficiency

Power density 218.6 W/m2 (1.95 percentage points above 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.04 V at -10 C (576.5 V string) and 49.26 V at -20 C (12 max).

 8 kW Reference Array

### 18 Panels = 8,460 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,781 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.78 * (1 + (-0.278/100) * (-10 - 25)) = 48.04 V | OCPD = 1.56 * 13.5 = 21.06 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M470W: Voc=43.78 V, beta_Voc=-0.278%/C, Isc=13.5 A, STC=470.0 W, Area=2.15 m2.

**Result:** 12 panels max on 600 V (576.5 V); 18 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for Auxin Solar AXN10M470W?

Official CEC datasheet figures for Auxin Solar AXN10M470W (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M470W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 432.3 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.78 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.83 V / 12.77 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.278 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.86% (2.15 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Auxin Solar AXN10M470W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Auxin Solar AXN10M470W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.11 kW | 301 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 18 | 8.46 kW | 417 sq ft | $2,117 | $3,580 |
| **10 kW Class** | 22 | 10.34 kW | 509 sq ft | $2,588 | $4,376 |

## How Many Auxin Solar AXN10M470W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Auxin Solar AXN10M470W (48.04 V at 14 F).

Computed from Voc=43.78V and beta_Voc=-0.278%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 49.26 V | 12 panels | 591.1 V | 20 panels |
| **-10 C (14 F)** | 48.04 V | 12 panels | 576.5 V | 20 panels |
| **0 C (32 F)** | 46.82 V | 12 panels | 561.8 V | 21 panels |
| **25 C (77 F STC)** | 43.78 V | 13 panels | 569.1 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M470W?

Competing CEC solar panels closest to Auxin Solar AXN10M470W in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-BFN10-470W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bfn10-470w-dg/) Aptos Solar Technology LLC | 470.0 W | Tie (0 W) | 42.38 V | 21.76% | 94.9% |
| [**Heliene 132HC-470 M10 SL**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-132hc-470-m10-sl/) Heliene | 470.0 W | Tie (0 W) | 45.25 V | 20.52% | 94.2% |
| [**CSI Solar Co Ltd CS61-60TM-470H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-60tm-470h/) CSI Solar Co Ltd | 470.0 W | Tie (0 W) | 42.0 V | 21.46% | 94.6% |
| [**Elin Energy (Sirius PV) ELNSM60M-HC-475**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-475/) Elin Energy (Sirius PV) | 475.0 W | +5.0 W | 41.82 V | 22.09% | 94.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M470W?

Evaluate Auxin Solar AXN10M470W (470.0 W STC, 43.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M470W reaches 49.26 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 417 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (417 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M470W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Auxin Solar AXN10M470W 8 kW Residential Fit

Needs 18 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 432.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M470W by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Auxin Solar AXN10M470W?

Multiplying Auxin Solar AXN10M470W's 13.5 A short-circuit current by 1.56 equals 21.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Auxin Solar AXN10M470W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 48.04 V cold Voc at 14 F and handles 13.5 A Isc; string inverters cap Auxin Solar AXN10M470W at 12 panels on 600 V.

### Is Auxin Solar AXN10M470W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Auxin Solar AXN10M470W rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.

## Related Pages

Compare Auxin Solar equipment, Aptos Solar Technology LLC DNA-120-BFN10-470W-DG specs, utility payback rates, and NEC string calculators alongside Auxin Solar AXN10M470W.

[All Auxin Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/auxin-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Auxin Solar

- [All Auxin Solar Specs](https://epri-peac.com/solar-equipment/brands/auxin-solar/)
- [Auxin Solar AXN10M610W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m610w/)
- [Auxin Solar AXN10M585W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m585w/)
- [Auxin Solar AXN10M560W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m560w/)
- [Auxin Solar AXN10M540B](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540b/)
- [Auxin Solar AXN10M540W](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540w/)