title: "Arka Energy Inc AEP-821-00012-A Specs (77.0W, 11.56V Voc)"
url: https://epri-peac.com/solar-equipment/modules/arka-energy-inc/arka-energy-inc-aep-821-00012-a/
description: "CEC datasheet for Arka Energy Inc AEP-821-00012-A: 77.0W STC, 11.56V Voc, 104-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Arka Energy Inc AEP-821-00012-A — CEC Solar Module Specifications

Manufacturer: [**Arka Energy Inc**](https://epri-peac.com/solar-equipment/brands/arka-energy-inc/) Registry: **CEC Verified Engineering Specification**

Arka Energy Inc AEP-821-00012-A is a 77.0 W STC (70.9 W PTC) Mono-c-Si solar module ranking #21,611 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 14.81% efficiency, 11.56 V Voc at 25 C, and 12.77 V cold Voc at -10 C (46 panels max per 600 V string).

- **STC Wattage** : 77.0 W

- **PTC Wattage** : 70.9 W

- **Voc @ 25C** : 11.56 V

- **Efficiency** : 14.81%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Arka Energy Inc AEP-821-00012-A Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Arka Energy Inc AEP-821-00012-A (Mono-c-Si) residential solar systems.

Arka Energy Inc AEP-821-00012-A delivers 148.1 W/m2 (5.10 percentage points below 19.91% CEC median) and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 104 panels (582 sq ft). At -4 F (-20 C), string voltage climbs to 13.11 V per unit, capping 600 V circuits at 45 panels. Compare specs directly with LUMA Resources LRSS (80.0 W).

## Where Does Arka Energy Inc AEP-821-00012-A Fall Across Listed CEC Models?

Comparison of Arka Energy Inc AEP-821-00012-A (77.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Arka Energy Inc AEP-821-00012-A?

Relative ranking of Arka Energy Inc AEP-821-00012-A across nameplate watts, 92.1% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Arka Energy Inc AEP-821-00012-A?

Summary of Arka Energy Inc AEP-821-00012-A output rank, 8 kW array size (104 panels), efficiency rating, and 600 V string limit.

Rank #21,611 / 21,677

### 77.0 W STC · Higher Than 0.3%

77.0 W STC (-308.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,044

### 14.81% Aperture Efficiency

Power density 148.1 W/m2 (5.10 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).

NEC 690.7 Limit

### 46 Panels Max @ -10 C (600 V)

Cold Voc reaches 12.77 V at -10 C (587.4 V string) and 13.11 V at -20 C (45 max).

 8 kW Reference Array

### 104 Panels = 8,008 W STC

Occupies 54.1 m2 (582 sq ft) producing 7,374 W PTC; NEC 690.8 OCPD floor is 12.99 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 11.56 * (1 + (-0.298/100) * (-10 - 25)) = 12.77 V | OCPD = 1.56 * 8.33 = 12.99 A

Inputs from CEC Modules.csv for Arka Energy Inc AEP-821-00012-A: Voc=11.56 V, beta_Voc=-0.298%/C, Isc=8.33 A, STC=77.0 W, Area=0.52 m2.

**Result:** 46 panels max on 600 V (587.4 V); 104 panels for 8 kW (582 sq ft).

## What Are the Published CEC Specifications for Arka Energy Inc AEP-821-00012-A?

Complete CEC test sheet for Arka Energy Inc AEP-821-00012-A including Isc (8.33 A), Voc (11.56 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Arka Energy Inc AEP-821-00012-A.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 77.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 70.9 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 11.56 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 9.71 V / 7.93 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.298 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.81% (0.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 17 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Arka Energy Inc AEP-821-00012-A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Arka Energy Inc AEP-821-00012-A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 78 | 6.01 kW | 437 sq ft | $1,504 | $2,544 |
| **8 kW Class** | 104 | 8.01 kW | 582 sq ft | $2,005 | $3,390 |
| **10 kW Class** | 130 | 10.01 kW | 728 sq ft | $2,505 | $4,236 |

## How Many Arka Energy Inc AEP-821-00012-A Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Arka Energy Inc AEP-821-00012-A (11.56 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=11.56V and beta_Voc=-0.298%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 13.11 V | 45 panels | 589.9 V | 76 panels |
| **-10 C (14 F)** | 12.77 V | 46 panels | 587.4 V | 78 panels |
| **0 C (32 F)** | 12.42 V | 48 panels | 596.2 V | 80 panels |
| **25 C (77 F STC)** | 11.56 V | 51 panels | 589.6 V | 86 panels |

## Which Cross-Brand Solar Modules Compare Closest to Arka Energy Inc AEP-821-00012-A?

Four comparable CEC modules such as LUMA Resources LRSS (80.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**LUMA Resources LRSS**](https://epri-peac.com/solar-equipment/modules/luma-resources/luma-resources-lrss/) LUMA Resources | 80.0 W | +3.0 W | 10.43 V | 16.0% | 90.0% |
| [**CertainTeed Apollo II - 75x**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-75x/) CertainTeed | 75.0 W | -2.0 W | 9.92 V | 14.15% | 85.6% |
| [**CertainTeed Apollo Tile II - 75x**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-tile-ii-75x/) CertainTeed | 75.0 W | -2.0 W | 9.92 V | 13.89% | 87.3% |
| [**CertainTeed Apollo II - 74x**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-74x/) CertainTeed | 74.0 W | -3.0 W | 9.86 V | 13.96% | 85.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Arka Energy Inc AEP-821-00012-A?

Evaluate Arka Energy Inc AEP-821-00012-A (77.0 W STC, 11.56 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Arka Energy Inc AEP-821-00012-A reaches 13.11 V per panel—exceeding 45 panels in series voids 600 V inverter warranties.
- Footprint constraint: 104 panels for an 8 kW build require 582 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 104 panels (582 sq ft).
- 2026 tax credit baseline: cash residential installs of Arka Energy Inc AEP-821-00012-A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Arka Energy Inc AEP-821-00012-A 8 kW Residential Fit

Needs 104 modules (582 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 46 panels (-10 C) or 45 panels (-20 C), or compare LUMA Resources LRSS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 70.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Arka Energy Inc AEP-821-00012-A by Arka Energy Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Arka Energy Inc AEP-821-00012-A panels fit on a 600 V winter solar string?

At -10 C (14 F), Arka Energy Inc AEP-821-00012-A cold Voc rises from 11.56 V to 12.77 V (beta_Voc -0.298%/C), capping a 600 V string at 46 panels (587.4 V).

### How much roof area does an 8 kW array of Arka Energy Inc AEP-821-00012-A need?

An 8 kW DC system uses 104 Arka Energy Inc AEP-821-00012-A modules (8,008 W STC / 7,374 W PTC), covering roughly 582 sq ft and saving ~$2,005/yr at 18.54 c/kWh.

### How does Arka Energy Inc AEP-821-00012-A compare against LUMA Resources LRSS?

Arka Energy Inc AEP-821-00012-A outputs 77.0 W STC (11.56 V Voc, rank #21,611 of 21,677), while LUMA Resources LRSS delivers 80.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Arka Energy Inc equipment, LUMA Resources LRSS specs, utility payback rates, and NEC string calculators alongside Arka Energy Inc AEP-821-00012-A.

[All Arka Energy Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/arka-energy-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Arka Energy Inc

- [All Arka Energy Inc Specs](https://epri-peac.com/solar-equipment/brands/arka-energy-inc/)
- [Arka Energy Inc AEP-821-00015-A](https://epri-peac.com/solar-equipment/modules/arka-energy-inc/arka-energy-inc-aep-821-00015-a/)