title: "Anji Technology AJP-M660-220 Specs (220.0W, 36.06V Voc)"
url: https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-220/
description: "CEC datasheet for Anji Technology AJP-M660-220: 220.0W STC, 36.06V Voc, 37-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Anji Technology AJP-M660-220 — CEC Solar Module Specifications

Manufacturer: [**Anji Technology**](https://epri-peac.com/solar-equipment/brands/anji-technology/) Registry: **CEC Verified Engineering Specification**

Anji Technology AJP-M660-220 is a 220.0 W STC (189.1 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.55% efficiency, 36.06 V Voc at 25 C, and 40.63 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 220.0 W

- **PTC Wattage** : 189.1 W

- **Voc @ 25C** : 36.06 V

- **Efficiency** : 13.55%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Anji Technology AJP-M660-220 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Anji Technology AJP-M660-220 (Multi-c-Si) residential solar systems.

Homeowners evaluating Anji Technology AJP-M660-220 need 28 panels for 6 kW or 37 panels (647 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (647 sq ft). Under NEC 690.7(A), beta_Voc (-0.362%/C) pushes open-circuit voltage to 40.63 V at 14 F and 41.93 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Anji Technology AJP-M660-220 Fall Across Listed CEC Models?

Comparison of Anji Technology AJP-M660-220 (220.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Dataset Percentiles Define Anji Technology AJP-M660-220?

Relative ranking of Anji Technology AJP-M660-220 across nameplate watts, 86.0% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Do the Dataset Ranks Show for Anji Technology AJP-M660-220?

Summary of Anji Technology AJP-M660-220 output rank, 8 kW array size (37 panels), efficiency rating, and 600 V string limit.

Rank #20,759 / 21,677

### 220.0 W STC · Higher Than 3.8%

220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,190

### 13.55% Aperture Efficiency

Power density 135.5 W/m2 (6.36 percentage points below 19.91% CEC median). PTC/STC ratio: 86.0% (rank #21,644).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.63 V at -10 C (568.8 V string) and 41.93 V at -20 C (14 max).

 8 kW Reference Array

### 37 Panels = 8,140 W STC

Occupies 60.1 m2 (647 sq ft) producing 6,997 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.06 * (1 + (-0.362/100) * (-10 - 25)) = 40.63 V | OCPD = 1.56 * 7.95 = 12.4 A

Inputs from CEC Modules.csv for Anji Technology AJP-M660-220: Voc=36.06 V, beta_Voc=-0.362%/C, Isc=7.95 A, STC=220.0 W, Area=1.624 m2.

**Result:** 14 panels max on 600 V (568.8 V); 37 panels for 8 kW (647 sq ft).

## What Are the Published CEC Specifications for Anji Technology AJP-M660-220?

Complete CEC test sheet for Anji Technology AJP-M660-220 including Isc (7.95 A), Voc (36.06 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Anji Technology AJP-M660-220.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 189.1 W (86.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.06 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.12 V / 7.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.362 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.55% (1.624 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Anji Technology AJP-M660-220 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Anji Technology AJP-M660-220.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 28 | 6.16 kW | 489 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 37 | 8.14 kW | 647 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 46 | 10.12 kW | 804 sq ft | $2,533 | $4,283 |

## How Many Anji Technology AJP-M660-220 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Anji Technology AJP-M660-220 (36.06 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.06V and beta_Voc=-0.362%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.93 V | 14 panels | 587.0 V | 23 panels |
| **-10 C (14 F)** | 40.63 V | 14 panels | 568.8 V | 24 panels |
| **0 C (32 F)** | 39.32 V | 15 panels | 589.8 V | 25 panels |
| **25 C (77 F STC)** | 36.06 V | 16 panels | 577.0 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Anji Technology AJP-M660-220?

Four comparable CEC modules such as Alps Technology ATI-M660-220 (220.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Alps Technology ATI-M660-220**](https://epri-peac.com/solar-equipment/modules/alps-technology/alps-technology-ati-m660-220/) Alps Technology | 220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| [**Centrosolar America DP60 220**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp60-220/) Centrosolar America | 220.0 W | Tie (0 W) | 36.26 V | 13.42% | 89.8% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM220-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm220-60/) Anhui Rinengzhongtian Semiconductor Development | 220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |
| [**Gintung Energy ASEC-220G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-220g6s/) Gintung Energy | 220.0 W | Tie (0 W) | 36.53 V | 13.66% | 89.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Anji Technology AJP-M660-220?

Evaluate Anji Technology AJP-M660-220 (220.0 W STC, 36.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Anji Technology AJP-M660-220 reaches 41.93 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 647 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (647 sq ft).
- 2026 tax credit baseline: cash residential installs of Anji Technology AJP-M660-220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Anji Technology AJP-M660-220 8 kW Residential Fit

Needs 37 modules (647 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Alps Technology ATI-M660-220.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 189.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Anji Technology AJP-M660-220 by Anji Technology grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Anji Technology AJP-M660-220 PTC wattage (189.1 W) lower than STC (220.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 189.1 W PTC (86.0% retention) across Anji Technology AJP-M660-220's 1.624 m2 aperture.

### Who should skip Anji Technology AJP-M660-220 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 37 Anji Technology AJP-M660-220 panels (647 sq ft) leave unusable roof gaps vs. Alps Technology ATI-M660-220.

### What is the 1,000 V commercial string limit for Anji Technology AJP-M660-220?

On 1,000 V commercial inverters at -10 C (40.63 V cold Voc), Anji Technology AJP-M660-220 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Anji Technology AJP-M660-220.

## Related Pages

Compare Anji Technology equipment, Alps Technology ATI-M660-220 specs, utility payback rates, and NEC string calculators alongside Anji Technology AJP-M660-220.

[All Anji Technology Certified Solar Models](https://epri-peac.com/solar-equipment/brands/anji-technology/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Anji Technology

- [All Anji Technology Specs](https://epri-peac.com/solar-equipment/brands/anji-technology/)
- [Anji Technology AJP-M660-250](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-250/)
- [Anji Technology AJP-M660-235](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-235/)
- [Anji Technology AJP-S572-180](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-s572-180/)