title: "AMPS Solar AMPS-585N-144SW Specs (585.0W, 52.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-585n-144sw/
description: "CEC datasheet for AMPS Solar AMPS-585N-144SW: 585.0W STC, 52.7V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# AMPS Solar AMPS-585N-144SW — CEC Solar Module Specifications

Manufacturer: [**AMPS Solar**](https://epri-peac.com/solar-equipment/brands/amps-solar/) Registry: **CEC Verified Engineering Specification**

AMPS Solar AMPS-585N-144SW is a 585.0 W STC (555.2 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.85% efficiency, 52.7 V Voc at 25 C, and 56.96 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 585.0 W

- **PTC Wattage** : 555.2 W

- **Voc @ 25C** : 52.7 V

- **Efficiency** : 22.85%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does AMPS Solar AMPS-585N-144SW Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AMPS Solar AMPS-585N-144SW (Mono-c-Si) residential solar systems.

Homeowners evaluating AMPS Solar AMPS-585N-144SW need 11 panels for 6 kW or 14 panels (386 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.231%/C) pushes open-circuit voltage to 56.96 V at 14 F and 58.18 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does AMPS Solar AMPS-585N-144SW Fall Across Listed CEC Models?

Comparison of AMPS Solar AMPS-585N-144SW (585.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Dataset Percentiles Define AMPS Solar AMPS-585N-144SW?

Relative ranking of AMPS Solar AMPS-585N-144SW across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for AMPS Solar AMPS-585N-144SW?

Summary of AMPS Solar AMPS-585N-144SW output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,751 / 21,677

### Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,413

### 22.85% Aperture Efficiency

Power density 228.5 W/m2 (2.94 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.96 V at -10 C (569.6 V string) and 58.18 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,190 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,773 W PTC; NEC 690.8 OCPD floor is 21.86 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.7 * (1 + (-0.231/100) * (-10 - 25)) = 56.96 V | OCPD = 1.56 * 14.01 = 21.86 A

Inputs from CEC Modules.csv for AMPS Solar AMPS-585N-144SW: Voc=52.7 V, beta_Voc=-0.231%/C, Isc=14.01 A, STC=585.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (569.6 V); 14 panels for 8 kW (386 sq ft).

## What Are the Published CEC Specifications for AMPS Solar AMPS-585N-144SW?

Complete CEC test sheet for AMPS Solar AMPS-585N-144SW including Isc (14.01 A), Voc (52.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AMPS Solar AMPS-585N-144SW.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 555.2 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.01 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 44.02 V / 13.29 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.231 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.85% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many AMPS Solar AMPS-585N-144SW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AMPS Solar AMPS-585N-144SW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.43 kW | 303 sq ft | $1,609 | $2,721 |
| **8 kW Class** | 14 | 8.19 kW | 386 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 18 | 10.53 kW | 496 sq ft | $2,636 | $4,457 |

## Which Sibling Wattage & Trim Variants Belong to This AMPS Solar Series?

Related AMPS Solar power steps and black/silver trims consolidated into this AMPS Solar AMPS-585N-144SW series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the AMPS Solar AMPS-585N-144SW wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **AMPS Solar AMPS-575N-144SW** | 575.0 W | 545.5 W | 52.3 V | 43.73 V | 22.46% |
| **AMPS Solar AMPS-580N-144SW** | 580.0 W | 550.3 W | 52.5 V | 43.88 V | 22.66% |
| **AMPS Solar AMPS-585N-144SW** | 585.0 W | 555.2 W | 52.7 V | 44.02 V | 22.85% |
| **AMPS Solar AMPS-590N-144SW** | 590.0 W | 560.0 W | 52.9 V | 44.17 V | 23.05% |
| **AMPS Solar AMPS-595N-144SW** | 595.0 W | 564.9 W | 53.1 V | 44.31 V | 23.24% |

## How Many AMPS Solar AMPS-585N-144SW Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AMPS Solar AMPS-585N-144SW (52.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=52.7V and beta_Voc=-0.231%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.18 V | 10 panels | 581.8 V | 17 panels |
| **-10 C (14 F)** | 56.96 V | 10 panels | 569.6 V | 17 panels |
| **0 C (32 F)** | 55.74 V | 10 panels | 557.4 V | 17 panels |
| **25 C (77 F STC)** | 52.7 V | 11 panels | 579.7 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-585N-144SW?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF (585.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-585-h-hc-bf/) Boviet Solar Technology Co Ltd | 585.0 W | Tie (0 W) | 52.61 V | 22.67% | 95.1% |
| [**Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-585-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 585.0 W | Tie (0 W) | 52.61 V | 22.67% | 95.1% |
| [**CSI Solar Co Ltd CS6W-585TB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6w-585tb-ag/) CSI Solar Co Ltd | 585.0 W | Tie (0 W) | 52.4 V | 23.31% | 95.0% |
| [**FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585**](https://epri-peac.com/solar-equipment/modules/fs-green-energies-private-limited/fs-green-energies-private-limited-fst-m10144g-585/) FS GREEN ENERGIES PRIVATE LIMITED | 585.0 W | Tie (0 W) | 53.1 V | 22.85% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-585N-144SW?

Evaluate AMPS Solar AMPS-585N-144SW (585.0 W STC, 52.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-585N-144SW reaches 58.18 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-585N-144SW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### AMPS Solar AMPS-585N-144SW 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 555.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AMPS Solar AMPS-585N-144SW by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is AMPS Solar AMPS-585N-144SW PTC wattage (555.2 W) lower than STC (585.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 555.2 W PTC (94.9% retention) across AMPS Solar AMPS-585N-144SW's 2.56 m2 aperture.

### Who should skip AMPS Solar AMPS-585N-144SW on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 AMPS Solar AMPS-585N-144SW panels (386 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF.

### What is the 1,000 V commercial string limit for AMPS Solar AMPS-585N-144SW?

On 1,000 V commercial inverters at -10 C (56.96 V cold Voc), AMPS Solar AMPS-585N-144SW fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AMPS Solar AMPS-585N-144SW.

## Related Pages

Compare AMPS Solar equipment, Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF specs, utility payback rates, and NEC string calculators alongside AMPS Solar AMPS-585N-144SW.

[All AMPS Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/amps-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From AMPS Solar

- [All AMPS Solar Specs](https://epri-peac.com/solar-equipment/brands/amps-solar/)
- [AMPS Solar AMPS-600N-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-600n-144sw/)
- [AMPS Solar AMPS-550P-144BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144bb/)
- [AMPS Solar AMPS-550P-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144sw/)
- [AMPS Solar AMPS-550P-72BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-72bb/)
- [AMPS Solar AMPS-540P-72BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-540p-72bb/)