title: "AMPS Solar AMPS-550P-144SW Specs (550.0W, 49.05V Voc)"
url: https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144sw/
description: "CEC datasheet for AMPS Solar AMPS-550P-144SW: 550.0W STC, 49.05V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# AMPS Solar AMPS-550P-144SW — CEC Solar Module Specifications

Manufacturer: [**AMPS Solar**](https://epri-peac.com/solar-equipment/brands/amps-solar/) Registry: **CEC Verified Engineering Specification**

AMPS Solar AMPS-550P-144SW is a 550.0 W STC (518.4 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.05 V Voc at 25 C, and 53.39 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 550.0 W

- **PTC Wattage** : 518.4 W

- **Voc @ 25C** : 49.05 V

- **Efficiency** : 21.48%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does AMPS Solar AMPS-550P-144SW Compare Against Peer CEC Listings?

Engineering position of AMPS Solar AMPS-550P-144SW (550.0 W STC) vs. Apollo Renewables Inc Apollo-M772BH-550TW across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, AMPS Solar AMPS-550P-144SW pairs strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677) with 49.05 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,776 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Apollo Renewables Inc Apollo-M772BH-550TW offers a 550.0 W alternative.

## Where Does AMPS Solar AMPS-550P-144SW Fall Across Listed CEC Models?

Plots AMPS Solar AMPS-550P-144SW at 550.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define AMPS Solar AMPS-550P-144SW?

Benchmarks AMPS Solar AMPS-550P-144SW on STC wattage, thermal PTC/STC retention, and 21.48 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for AMPS Solar AMPS-550P-144SW?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AMPS Solar AMPS-550P-144SW by AMPS Solar.

Rank #2,737 / 21,677

### Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,517

### 21.48% Aperture Efficiency

Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.39 V at -10 C (587.3 V string) and 54.63 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,250 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,776 W PTC; NEC 690.8 OCPD floor is 22.12 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.05 * (1 + (-0.253/100) * (-10 - 25)) = 53.39 V | OCPD = 1.56 * 14.18 = 22.12 A

Inputs from CEC Modules.csv for AMPS Solar AMPS-550P-144SW: Voc=49.05 V, beta_Voc=-0.253%/C, Isc=14.18 A, STC=550.0 W, Area=2.56 m2.

**Result:** 11 panels max on 600 V (587.3 V); 15 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for AMPS Solar AMPS-550P-144SW?

Laboratory test ratings recorded for AMPS Solar AMPS-550P-144SW (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for AMPS Solar AMPS-550P-144SW.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 518.4 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.18 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.55 V / 13.25 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.253 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.48% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many AMPS Solar AMPS-550P-144SW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (413 sq ft at 8 kW), and estimated Year-1 electric bill offset for AMPS Solar AMPS-550P-144SW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.05 kW | 303 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 15 | 8.25 kW | 413 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 19 | 10.45 kW | 524 sq ft | $2,616 | $4,423 |

## How Many AMPS Solar AMPS-550P-144SW Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for AMPS Solar AMPS-550P-144SW (beta_Voc -0.253%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.05V and beta_Voc=-0.253%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.63 V | 10 panels | 546.3 V | 18 panels |
| **-10 C (14 F)** | 53.39 V | 11 panels | 587.3 V | 18 panels |
| **0 C (32 F)** | 52.15 V | 11 panels | 573.6 V | 19 panels |
| **25 C (77 F STC)** | 49.05 V | 12 panels | 588.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-550P-144SW?

Closest cross-brand CEC competitors to AMPS Solar AMPS-550P-144SW matched near 550.0 W STC and 49.05 V Voc, led by Apollo Renewables Inc Apollo-M772BH-550TW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Apollo Renewables Inc Apollo-M772BH-550TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m772bh-550tw/) Apollo Renewables Inc | 550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |
| [**Exiom Solution S A EX550-144BMH-DG**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144bmh-dg/) Exiom Solution S A | 550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| [**Exiom Solution S A EX550-144M-BMH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144m-bmh/) Exiom Solution S A | 550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |
| [**Bluesun Solar CoLtd BSM550M10-72HBD**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm550m10-72hbd/) Bluesun Solar CoLtd | 550.0 W | Tie (0 W) | 49.92 V | 21.23% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-550P-144SW?

Evaluate AMPS Solar AMPS-550P-144SW (550.0 W STC, 49.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-550P-144SW reaches 54.63 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-550P-144SW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### AMPS Solar AMPS-550P-144SW 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M772BH-550TW.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 518.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AMPS Solar AMPS-550P-144SW by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for AMPS Solar AMPS-550P-144SW?

Multiplying AMPS Solar AMPS-550P-144SW's 14.18 A short-circuit current by 1.56 equals 22.12 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can AMPS Solar AMPS-550P-144SW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.39 V cold Voc at 14 F and handles 14.18 A Isc; string inverters cap AMPS Solar AMPS-550P-144SW at 11 panels on 600 V.

### Is AMPS Solar AMPS-550P-144SW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AMPS Solar AMPS-550P-144SW rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare AMPS Solar equipment, Apollo Renewables Inc Apollo-M772BH-550TW specs, utility payback rates, and NEC string calculators alongside AMPS Solar AMPS-550P-144SW.

[All AMPS Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/amps-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From AMPS Solar

- [All AMPS Solar Specs](https://epri-peac.com/solar-equipment/brands/amps-solar/)
- [AMPS Solar AMPS-600N-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-600n-144sw/)
- [AMPS Solar AMPS-585N-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-585n-144sw/)
- [AMPS Solar AMPS-550P-144BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144bb/)
- [AMPS Solar AMPS-550P-72BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-72bb/)
- [AMPS Solar AMPS-540P-72BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-540p-72bb/)