title: "AMPS Solar AMPS-450N-108BB Specs (450.0W, 40.16V Voc)"
url: https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-450n-108bb/
description: "CEC datasheet for AMPS Solar AMPS-450N-108BB: 450.0W STC, 40.16V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# AMPS Solar AMPS-450N-108BB — CEC Solar Module Specifications

Manufacturer: [**AMPS Solar**](https://epri-peac.com/solar-equipment/brands/amps-solar/) Registry: **CEC Verified Engineering Specification**

AMPS Solar AMPS-450N-108BB is a 450.0 W STC (428.2 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 23.2% efficiency, 40.16 V Voc at 25 C, and 43.41 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 450.0 W

- **PTC Wattage** : 428.2 W

- **Voc @ 25C** : 40.16 V

- **Efficiency** : 23.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does AMPS Solar AMPS-450N-108BB Compare Against Peer CEC Listings?

Solar engineering breakdown for AMPS Solar AMPS-450N-108BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Measured at 450.0 W STC and 428.2 W PTC, AMPS Solar AMPS-450N-108BB sits +65.0 W vs all-CEC median (top 27.8%; higher than 72.2% of peers) among 21,677 listed modules. Power density reaches 232.0 W/m2 (3.29 percentage points above 19.91% CEC median). Mid-range 40.16 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer ES Foundry Corp ES-DN8-H54B-450 rates 450.0 W.

## Where Does AMPS Solar AMPS-450N-108BB Fall Across Listed CEC Models?

Distribution marker showing AMPS Solar AMPS-450N-108BB (450.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define AMPS Solar AMPS-450N-108BB?

Dataset percentiles tracking AMPS Solar AMPS-450N-108BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for AMPS Solar AMPS-450N-108BB?

Benchmark highlights for AMPS Solar AMPS-450N-108BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #5,679 / 21,677

### Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #871

### 23.2% Aperture Efficiency

Power density 232.0 W/m2 (3.29 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.41 V at -10 C (564.3 V string) and 44.33 V at -20 C (13 max).

 8 kW Reference Array

### 18 Panels = 8,100 W STC

Occupies 34.9 m2 (376 sq ft) producing 7,708 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.16 * (1 + (-0.231/100) * (-10 - 25)) = 43.41 V | OCPD = 1.56 * 14.19 = 22.14 A

Inputs from CEC Modules.csv for AMPS Solar AMPS-450N-108BB: Voc=40.16 V, beta_Voc=-0.231%/C, Isc=14.19 A, STC=450.0 W, Area=1.94 m2.

**Result:** 13 panels max on 600 V (564.3 V); 18 panels for 8 kW (376 sq ft).

## What Are the Published CEC Specifications for AMPS Solar AMPS-450N-108BB?

Official CEC datasheet figures for AMPS Solar AMPS-450N-108BB (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for AMPS Solar AMPS-450N-108BB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 428.2 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.16 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.03 V / 13.23 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.231 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.2% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many AMPS Solar AMPS-450N-108BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many AMPS Solar AMPS-450N-108BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.3 kW | 292 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 18 | 8.1 kW | 376 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 23 | 10.35 kW | 480 sq ft | $2,591 | $4,380 |

## How Many AMPS Solar AMPS-450N-108BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on AMPS Solar AMPS-450N-108BB (43.41 V at 14 F).

Computed from Voc=40.16V and beta_Voc=-0.231%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.33 V | 13 panels | 576.3 V | 22 panels |
| **-10 C (14 F)** | 43.41 V | 13 panels | 564.3 V | 23 panels |
| **0 C (32 F)** | 42.48 V | 14 panels | 594.7 V | 23 panels |
| **25 C (77 F STC)** | 40.16 V | 14 panels | 562.2 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-450N-108BB?

Competing CEC solar panels closest to AMPS Solar AMPS-450N-108BB in nameplate wattage and Voc, starting with ES Foundry Corp ES-DN8-H54B-450.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ES Foundry Corp ES-DN8-H54B-450**](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dn8-h54b-450/) ES Foundry Corp | 450.0 W | Tie (0 W) | 39.54 V | 23.11% | 95.2% |
| [**CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT450-108TNB10**](https://epri-peac.com/solar-equipment/modules/cw-enerj-m-hend-sl-k-t-caret-ve-sanay-anon-m-rket/cw-enerj-m-hend-sl-k-t-caret-ve-sanay-anon-m-rket-cwt450-108tnb10/) CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET | 450.0 W | Tie (0 W) | 39.53 V | 23.08% | 96.1% |
| [**Aptos Solar Technology LLC DNA-108-BFN10-455W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bfn10-455w-dg/) Aptos Solar Technology LLC | 455.0 W | +5.0 W | 39.7 V | 23.45% | 95.1% |
| [**CertainTeed CTTC455HC12-08**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc455hc12-08/) CertainTeed | 455.0 W | +5.0 W | 39.0 V | 23.33% | 94.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-450N-108BB?

Evaluate AMPS Solar AMPS-450N-108BB (450.0 W STC, 40.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-450N-108BB reaches 44.33 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-450N-108BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### AMPS Solar AMPS-450N-108BB 8 kW Residential Fit

Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare ES Foundry Corp ES-DN8-H54B-450.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 428.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AMPS Solar AMPS-450N-108BB by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many AMPS Solar AMPS-450N-108BB panels fit on a 600 V winter solar string?

At -10 C (14 F), AMPS Solar AMPS-450N-108BB cold Voc rises from 40.16 V to 43.41 V (beta_Voc -0.231%/C), capping a 600 V string at 13 panels (564.3 V).

### How much roof area does an 8 kW array of AMPS Solar AMPS-450N-108BB need?

An 8 kW DC system uses 18 AMPS Solar AMPS-450N-108BB modules (8,100 W STC / 7,708 W PTC), covering roughly 376 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does AMPS Solar AMPS-450N-108BB compare against ES Foundry Corp ES-DN8-H54B-450?

AMPS Solar AMPS-450N-108BB outputs 450.0 W STC (40.16 V Voc, rank #5,679 of 21,677), while ES Foundry Corp ES-DN8-H54B-450 delivers 450.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare AMPS Solar equipment, ES Foundry Corp ES-DN8-H54B-450 specs, utility payback rates, and NEC string calculators alongside AMPS Solar AMPS-450N-108BB.

[All AMPS Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/amps-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From AMPS Solar

- [All AMPS Solar Specs](https://epri-peac.com/solar-equipment/brands/amps-solar/)
- [AMPS Solar AMPS-600N-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-600n-144sw/)
- [AMPS Solar AMPS-585N-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-585n-144sw/)
- [AMPS Solar AMPS-550P-144BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144bb/)
- [AMPS Solar AMPS-550P-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144sw/)
- [AMPS Solar AMPS-550P-72BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-72bb/)