Manufacturer: [**AMPS Solar**](https://epri-peac.com/solar-equipment/brands/amps-solar/) Registry: **CEC Verified Engineering Specification**

AMPS Solar AMPS-405P-54BB is a 405.0 W STC (381.7 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.88% efficiency, 37.25 V Voc at 25 C, and 40.69 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 381.7 W

- **Voc @ 25C** : 37.25 V

- **Efficiency** : 20.88%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does AMPS Solar AMPS-405P-54BB Compare Against Peer CEC Listings?

How AMPS Solar AMPS Solar AMPS-405P-54BB handles rooftop heat (381.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, AMPS Solar AMPS-405P-54BB exhibits 13.86 A short-circuit current, requiring a 21.62 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,961 of 21,677 (5.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.8 m2 for an 8 kW system (25 panels for 10 kW). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does AMPS Solar AMPS-405P-54BB Fall Across Listed CEC Models?

Where AMPS Solar AMPS-405P-54BB (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define AMPS Solar AMPS-405P-54BB?

Percentile placement of AMPS Solar AMPS-405P-54BB across power density (208.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for AMPS Solar AMPS-405P-54BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing AMPS Solar AMPS-405P-54BB specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,925

### 20.88% Aperture Efficiency

Power density 208.8 W/m2 (0.97 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.69 V at -10 C (569.7 V string) and 41.68 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.25 * (1 + (-0.264/100) * (-10 - 25)) = 40.69 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for AMPS Solar AMPS-405P-54BB: Voc=37.25 V, beta_Voc=-0.264%/C, Isc=13.86 A, STC=405.0 W, Area=1.94 m2.

**Result:** 14 panels max on 600 V (569.7 V); 20 panels for 8 kW (418 sq ft).

## What Are the Published CEC Specifications for AMPS Solar AMPS-405P-54BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AMPS Solar AMPS-405P-54BB.

Official California Energy Commission (NREL SAM) test parameters for AMPS Solar AMPS-405P-54BB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 381.7 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.24 V / 12.97 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.264 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.88% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many AMPS Solar AMPS-405P-54BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AMPS Solar AMPS-405P-54BB (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 313 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 418 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 522 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This AMPS Solar Series?

All closely matched AMPS Solar wattages and cosmetic trims sharing the AMPS Solar AMPS-405P-54BB architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the AMPS Solar AMPS-405P-54BB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **AMPS Solar AMPS-400P-54BB** | 400.0 W | 376.9 W | 37.0 V | 31.05 V | 20.62% |
| **AMPS Solar AMPS-405P-54BB** | 405.0 W | 381.7 W | 37.25 V | 31.24 V | 20.88% |
| **AMPS Solar AMPS-410P-54BB** | 410.0 W | 386.5 W | 37.5 V | 31.43 V | 21.13% |

## How Many AMPS Solar AMPS-405P-54BB Modules Fit in a Cold-Weather String?

Maximum series module counts for AMPS Solar AMPS-405P-54BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.25V and beta_Voc=-0.264%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.68 V | 14 panels | 583.5 V | 23 panels |
| **-10 C (14 F)** | 40.69 V | 14 panels | 569.7 V | 24 panels |
| **0 C (32 F)** | 39.71 V | 15 panels | 595.6 V | 25 panels |
| **25 C (77 F STC)** | 37.25 V | 16 panels | 596.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-405P-54BB?

Alternative CEC solar modules from competing brands near AMPS Solar AMPS-405P-54BB (405.0 W), including CertainTeed CTM10405HC11-06. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CTM10405HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10405hc11-06/) CertainTeed | 405.0 W | Tie (0 W) | 37.23 V | 20.77% | 93.8% |
| [**Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV**](https://epri-peac.com/solar-equipment/modules/changzhou-eging-photovoltaic-technology-co-ltd/changzhou-eging-photovoltaic-technology-co-ltd-eg-405m54-hlv/) Changzhou EGing Photovoltaic Technology Co Ltd | 405.0 W | Tie (0 W) | 37.2 V | 20.77% | 93.8% |
| [**Convalt Manufacturing LLC CVLT405-108M-BB**](https://epri-peac.com/solar-equipment/modules/convalt-manufacturing-llc/convalt-manufacturing-llc-cvlt405-108m-bb/) Convalt Manufacturing LLC | 405.0 W | Tie (0 W) | 37.36 V | 20.88% | 92.0% |
| [**Alexus Solar ALEX-405-B-54-S**](https://epri-peac.com/solar-equipment/modules/alexus-solar/alexus-solar-alex-405-b-54-s/) Alexus Solar | 405.0 W | Tie (0 W) | 37.38 V | 20.77% | 92.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-405P-54BB?

Evaluate AMPS Solar AMPS-405P-54BB (405.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-405P-54BB reaches 41.68 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-405P-54BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### AMPS Solar AMPS-405P-54BB 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTM10405HC11-06.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AMPS Solar AMPS-405P-54BB by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is AMPS Solar AMPS-405P-54BB PTC wattage (381.7 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 381.7 W PTC (94.2% retention) across AMPS Solar AMPS-405P-54BB's 1.94 m2 aperture.

### Who should skip AMPS Solar AMPS-405P-54BB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 AMPS Solar AMPS-405P-54BB panels (418 sq ft) leave unusable roof gaps vs. CertainTeed CTM10405HC11-06.

### What is the 1,000 V commercial string limit for AMPS Solar AMPS-405P-54BB?

On 1,000 V commercial inverters at -10 C (40.69 V cold Voc), AMPS Solar AMPS-405P-54BB fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AMPS Solar AMPS-405P-54BB.

## Related Pages

Compare AMPS Solar equipment, CertainTeed CTM10405HC11-06 specs, utility payback rates, and NEC string calculators alongside AMPS Solar AMPS-405P-54BB.

[All AMPS Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/amps-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From AMPS Solar

- [All AMPS Solar Specs](https://epri-peac.com/solar-equipment/brands/amps-solar/)
- [AMPS Solar AMPS-600N-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-600n-144sw/)
- [AMPS Solar AMPS-585N-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-585n-144sw/)
- [AMPS Solar AMPS-550P-144BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144bb/)
- [AMPS Solar AMPS-550P-144SW](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144sw/)
- [AMPS Solar AMPS-550P-72BB](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-72bb/)