title: "ALTERNATIVE ENERGY (AE) SOLAR CO Specs (395.0W, 36.94V Voc)"
url: https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae395md-108/
description: "CEC datasheet for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108: 395.0W STC, 36.94V Voc, 21-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 — CEC Solar Module Specifications

Manufacturer: [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD**](https://epri-peac.com/solar-equipment/brands/alternative-energy-ae-solar-co-ltd/) Registry: **CEC Verified Engineering Specification**

ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 is a 395.0 W STC (365.7 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.47% efficiency, 36.94 V Voc at 25 C, and 40.37 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 365.7 W

- **Voc @ 25C** : 36.94 V

- **Efficiency** : 20.47%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 (Mono-c-Si) residential solar systems.

Homeowners evaluating ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 need 16 panels for 6 kW or 21 panels (436 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (436 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.265%/C) pushes open-circuit voltage to 40.37 V at 14 F and 41.35 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 Fall Across Listed CEC Models?

Comparison of ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108?

Relative ranking of ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108?

Summary of ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,713

### 20.47% Aperture Efficiency

Power density 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.37 V at -10 C (565.2 V string) and 41.35 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 40.5 m2 (436 sq ft) producing 7,680 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.94 * (1 + (-0.265/100) * (-10 - 25)) = 40.37 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108: Voc=36.94 V, beta_Voc=-0.265%/C, Isc=13.71 A, STC=395.0 W, Area=1.93 m2.

**Result:** 14 panels max on 600 V (565.2 V); 21 panels for 8 kW (436 sq ft).

## What Are the Published CEC Specifications for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108?

Complete CEC test sheet for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 including Isc (13.71 A), Voc (36.94 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 365.7 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.94 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.57 V / 12.92 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.265 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.47% (1.93 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 332 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 436 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 540 sq ft | $2,570 | $4,347 |

## Which Sibling Wattage & Trim Variants Belong to This ALTERNATIVE ENERGY (AE) SOLAR CO LTD Series?

Related ALTERNATIVE ENERGY (AE) SOLAR CO LTD power steps and black/silver trims consolidated into this ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 series guide.

Sibling CEC listings grouped into the ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108** | 390.0 W | 360.9 W | 36.81 V | 30.4 V | 20.21% |
| **ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108** | 395.0 W | 365.7 W | 36.94 V | 30.57 V | 20.47% |

## How Many ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 (36.94 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.94V and beta_Voc=-0.265%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.35 V | 14 panels | 578.9 V | 24 panels |
| **-10 C (14 F)** | 40.37 V | 14 panels | 565.2 V | 24 panels |
| **0 C (32 F)** | 39.39 V | 15 panels | 590.9 V | 25 panels |
| **25 C (77 F STC)** | 36.94 V | 16 panels | 591.0 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108?

Four comparable CEC modules such as Dehui Solar Power (Vietnam) CoLtd DH-M154W 395W (395.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Dehui Solar Power (Vietnam) CoLtd DH-M154W 395W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m154w-395w/) Dehui Solar Power (Vietnam) CoLtd | 395.0 W | Tie (0 W) | 36.94 V | 20.47% | 92.6% |
| [**Aptos Solar Technology LLC DNA-108-MF10-395W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mf10-395w/) Aptos Solar Technology LLC | 395.0 W | Tie (0 W) | 36.98 V | 20.26% | 93.7% |
| [**BYD Company Limited BYD395MLK-27**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd395mlk-27/) BYD Company Limited | 395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.6% |
| [**CertainTeed CTM10395HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10395hc11-06/) CertainTeed | 395.0 W | Tie (0 W) | 36.98 V | 20.26% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108?

Evaluate ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 (395.0 W STC, 36.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 reaches 41.35 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 436 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (436 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 8 kW Residential Fit

Needs 21 modules (436 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M154W 395W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 by ALTERNATIVE ENERGY (AE) SOLAR CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 PTC wattage (365.7 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 365.7 W PTC (92.6% retention) across ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108's 1.93 m2 aperture.

### Who should skip ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 panels (436 sq ft) leave unusable roof gaps vs. Dehui Solar Power (Vietnam) CoLtd DH-M154W 395W.

### What is the 1,000 V commercial string limit for ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108?

On 1,000 V commercial inverters at -10 C (40.37 V cold Voc), ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 fits up to 24 panels per series string.

## Related Pages

Compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD equipment, Dehui Solar Power (Vietnam) CoLtd DH-M154W 395W specs, utility payback rates, and NEC string calculators alongside ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108.

[All ALTERNATIVE ENERGY (AE) SOLAR CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/alternative-energy-ae-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From ALTERNATIVE ENERGY (AE) SOLAR CO LTD

- [All ALTERNATIVE ENERGY (AE) SOLAR CO LTD Specs](https://epri-peac.com/solar-equipment/brands/alternative-energy-ae-solar-co-ltd/)
- [ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae550md-144/)
- [ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144E](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae550md-144e/)
- [ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae540md-144/)
- [ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144E](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae540md-144e/)
- [ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144BS](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae535md-144bs/)