title: "Advanced Solar Power (Hangzhou) Specs (80.0W, 118.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/advanced-solar-power-hangzhou/advanced-solar-power-hangzhou-asp-s1-80/
description: "CEC datasheet for Advanced Solar Power (Hangzhou) ASP-S1-80: 80.0W STC, 118.9V Voc, 100-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Advanced Solar Power (Hangzhou) ASP-S1-80 — CEC Solar Module Specifications

Manufacturer: [**Advanced Solar Power (Hangzhou)**](https://epri-peac.com/solar-equipment/brands/advanced-solar-power-hangzhou/) Registry: **CEC Verified Engineering Specification**

Advanced Solar Power (Hangzhou) ASP-S1-80 is a 80.0 W STC (75.2 W PTC) Thin Film solar module ranking #21,605 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 11.11% efficiency, 118.9 V Voc at 25 C, and 131.63 V cold Voc at -10 C (4 panels max per 600 V string).

- **STC Wattage** : 80.0 W

- **PTC Wattage** : 75.2 W

- **Voc @ 25C** : 118.9 V

- **Efficiency** : 11.11%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Advanced Solar Power (Hangzhou) ASP-S1-80 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Advanced Solar Power (Hangzhou) ASP-S1-80 (Thin Film) residential solar systems.

Advanced Solar Power (Hangzhou) ASP-S1-80 delivers 111.1 W/m2 (8.80 percentage points below 19.91% CEC median) and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 100 panels (775 sq ft). At -4 F (-20 C), string voltage climbs to 135.27 V per unit, capping 600 V circuits at 4 panels. Compare specs directly with Zhongshan Ruike New Energy Co Ltd RK-95 (95.0 W).

## Where Does Advanced Solar Power (Hangzhou) ASP-S1-80 Fall Across Listed CEC Models?

Comparison of Advanced Solar Power (Hangzhou) ASP-S1-80 (80.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Advanced Solar Power (Hangzhou) ASP-S1-80?

Relative ranking of Advanced Solar Power (Hangzhou) ASP-S1-80 across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Advanced Solar Power (Hangzhou) ASP-S1-80?

Summary of Advanced Solar Power (Hangzhou) ASP-S1-80 output rank, 8 kW array size (100 panels), efficiency rating, and 600 V string limit.

Rank #21,605 / 21,677

### 80.0 W STC · Higher Than 0.3%

80.0 W STC (-305.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,596

### 11.11% Aperture Efficiency

Power density 111.1 W/m2 (8.80 percentage points below 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

### 4 Panels Max @ -10 C (600 V)

Cold Voc reaches 131.63 V at -10 C (526.5 V string) and 135.27 V at -20 C (4 max).

 8 kW Reference Array

### 100 Panels = 8,000 W STC

Occupies 72.0 m2 (775 sq ft) producing 7,520 W PTC; NEC 690.8 OCPD floor is 1.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 118.9 * (1 + (-0.306/100) * (-10 - 25)) = 131.63 V | OCPD = 1.56 * 0.95 = 1.48 A

Inputs from CEC Modules.csv for Advanced Solar Power (Hangzhou) ASP-S1-80: Voc=118.9 V, beta_Voc=-0.306%/C, Isc=0.95 A, STC=80.0 W, Area=0.72 m2.

**Result:** 4 panels max on 600 V (526.5 V); 100 panels for 8 kW (775 sq ft).

## What Are the Published CEC Specifications for Advanced Solar Power (Hangzhou) ASP-S1-80?

Complete CEC test sheet for Advanced Solar Power (Hangzhou) ASP-S1-80 including Isc (0.95 A), Voc (118.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Advanced Solar Power (Hangzhou) ASP-S1-80.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 80.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 75.2 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 118.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 0.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 94.1 V / 0.85 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.306 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 11.11% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 145 cells (Thin Film) | Monofacial backsheet |

## How Many Advanced Solar Power (Hangzhou) ASP-S1-80 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Advanced Solar Power (Hangzhou) ASP-S1-80.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 75 | 6.0 kW | 581 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 100 | 8.0 kW | 775 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 125 | 10.0 kW | 969 sq ft | $2,503 | $4,232 |

## How Many Advanced Solar Power (Hangzhou) ASP-S1-80 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Advanced Solar Power (Hangzhou) ASP-S1-80 (118.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=118.9V and beta_Voc=-0.306%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 135.27 V | 4 panels | 541.1 V | 7 panels |
| **-10 C (14 F)** | 131.63 V | 4 panels | 526.5 V | 7 panels |
| **0 C (32 F)** | 128.0 V | 4 panels | 512.0 V | 7 panels |
| **25 C (77 F STC)** | 118.9 V | 5 panels | 594.5 V | 8 panels |

## Which Cross-Brand Solar Modules Compare Closest to Advanced Solar Power (Hangzhou) ASP-S1-80?

Four comparable CEC modules such as Zhongshan Ruike New Energy Co Ltd RK-95 (95.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Zhongshan Ruike New Energy Co Ltd RK-95**](https://epri-peac.com/solar-equipment/modules/zhongshan-ruike-new-energy-co-ltd/zhongshan-ruike-new-energy-co-ltd-rk-95/) Zhongshan Ruike New Energy Co Ltd | 95.0 W | +15.0 W | 116.4 V | 13.19% | 92.8% |
| [**Du Pont Apollo DA095-A2**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da095-a2/) Du Pont Apollo | 95.0 W | +15.0 W | 100.0 V | 6.17% | 90.8% |
| [**Du Pont Apollo DA102-A6**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da102-a6/) Du Pont Apollo | 102.0 W | +22.0 W | 100.0 V | 6.62% | 94.2% |
| [**Du Pont Apollo DA105-A2**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da105-a2/) Du Pont Apollo | 105.0 W | +25.0 W | 100.0 V | 6.82% | 91.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Advanced Solar Power (Hangzhou) ASP-S1-80?

Evaluate Advanced Solar Power (Hangzhou) ASP-S1-80 (80.0 W STC, 118.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Advanced Solar Power (Hangzhou) ASP-S1-80 reaches 135.27 V per panel—exceeding 4 panels in series voids 600 V inverter warranties.
- Footprint constraint: 100 panels for an 8 kW build require 775 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 100 panels (775 sq ft).
- 2026 tax credit baseline: cash residential installs of Advanced Solar Power (Hangzhou) ASP-S1-80 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Advanced Solar Power (Hangzhou) ASP-S1-80 8 kW Residential Fit

Needs 100 modules (775 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 4 panels (-10 C) or 4 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-95.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 75.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Advanced Solar Power (Hangzhou) ASP-S1-80 by Advanced Solar Power (Hangzhou) grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Advanced Solar Power (Hangzhou) ASP-S1-80 panels fit on a 600 V winter solar string?

At -10 C (14 F), Advanced Solar Power (Hangzhou) ASP-S1-80 cold Voc rises from 118.9 V to 131.63 V (beta_Voc -0.306%/C), capping a 600 V string at 4 panels (526.5 V).

### How much roof area does an 8 kW array of Advanced Solar Power (Hangzhou) ASP-S1-80 need?

An 8 kW DC system uses 100 Advanced Solar Power (Hangzhou) ASP-S1-80 modules (8,000 W STC / 7,520 W PTC), covering roughly 775 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does Advanced Solar Power (Hangzhou) ASP-S1-80 compare against Zhongshan Ruike New Energy Co Ltd RK-95?

Advanced Solar Power (Hangzhou) ASP-S1-80 outputs 80.0 W STC (118.9 V Voc, rank #21,605 of 21,677), while Zhongshan Ruike New Energy Co Ltd RK-95 delivers 95.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Advanced Solar Power (Hangzhou) equipment, Zhongshan Ruike New Energy Co Ltd RK-95 specs, utility payback rates, and NEC string calculators alongside Advanced Solar Power (Hangzhou) ASP-S1-80.

[All Advanced Solar Power (Hangzhou) Certified Solar Models](https://epri-peac.com/solar-equipment/brands/advanced-solar-power-hangzhou/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Advanced Solar Power (Hangzhou)

- [All Advanced Solar Power (Hangzhou) Specs](https://epri-peac.com/solar-equipment/brands/advanced-solar-power-hangzhou/)