title: "Yaskawa Solectria Solar: SGI Inverter (507,000W)"
url: https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-sgi-500xtm-380v/
description: "CEC specs for Yaskawa Solectria Solar: SGI 500XTM {380V}: 507,000W AC, 380V, 1000A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Yaskawa Solectria Solar: SGI 500XTM {380V} — CEC Inverter Specifications

Manufacturer: [**Yaskawa Solectria Solar**](https://epri-peac.com/solar-equipment/brands/yaskawa-solectria-solar/) Registry: **CEC Verified Engineering Specification**

Yaskawa Solectria Solar: SGI 500XTM {380V} outputs 507,000 W AC at 380 V, 3-phase (770.3 A continuous, 1,000 A OCPD), ranking #1,002 of 2,343 CEC inverters at 97.01% efficiency with a 545-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 507,000 W

- **AC Voltage** : 380 V, 3-phase

- **Min PV Breaker** : 1,000 A (parallel Cu feeders)

- **CEC Efficiency** : 97.01%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Yaskawa Solectria Solar: SGI 500XTM {380V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,002), 545-820 V MPPT tracking, and panel fit for Yaskawa Solectria Solar: SGI 500XTM {380V}.

Operating at 380 V, 3-phase, Yaskawa Solectria Solar: SGI 500XTM {380V} converts DC array energy at 97.01% CEC weighted efficiency (top 43.2%; higher than 56.8% of peers) with a 820 V max DC input and 849.817 A max input current for NEC 690.7 string safety. Compare this 507,000 W grid-tied PV inverter directly with EPC Power Corp: 50-200100 {720V} (561,806 W). Commercial 380 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (380V) or NEC 705.11 supply-side tap.

## Where Does Yaskawa Solectria Solar: SGI 500XTM {380V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Yaskawa Solectria Solar: SGI 500XTM {380V} at 507,000 W continuous AC output. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define Yaskawa Solectria Solar: SGI 500XTM {380V}?

Dataset percentiles comparing Yaskawa Solectria Solar: SGI 500XTM {380V} against 2,343 certified grid-support inverters nationwide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Do the Dataset Ranks Show for Yaskawa Solectria Solar: SGI 500XTM {380V}?

Engineering highlights for Yaskawa Solectria Solar: SGI 500XTM {380V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #1,002 / 2,343

### 97.01% CEC Weighted Efficiency

-0.07 pts vs the 97.08% 380 V median; overall power rank #192 (507,000 W, top 8.2%; higher than 91.8% of peers).

NEC 705.12 Check

### 1,000 A Required Backfeed OCPD

125% x 770.3 A = 962.9 A -> 1,000 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 545 V - 820 V (Max 820 V DC)

Tracking span of 275.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 380 V, 3-phase switchgear (200A Bus / 200A Main (380V) to 1,200A Bus / 1,200A Main (380V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 507000.0W / 380 V 3-phase -> 770.3 A | Breaker >= 1.25 * 770.3 = 962.9 A -> 1,000 A

CEC Inverters.csv for Yaskawa Solectria Solar: SGI 500XTM {380V}: Paco=507000.0 W, Vac=380 V, Vdcmax=820.0 V, Eff=97.01%.

**Result:** Min 1,000 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (380V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for Yaskawa Solectria Solar: SGI 500XTM {380V}?

California Energy Commission Solar Equipment List parameters for Yaskawa Solectria Solar: SGI 500XTM {380V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Yaskawa Solectria Solar: SGI 500XTM {380V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 507,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 380 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 820 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 545 V - 820 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 849.817 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.01% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Yaskawa Solectria Solar: SGI 500XTM {380V} (380 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Yaskawa Solectria Solar: SGI 500XTM {380V} (1,000 A OCPD). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Evaluates Yaskawa Solectria Solar: SGI 500XTM {380V} (1000 A required OCPD at 380 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (380V)** | 40 A | 1,000 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (380V)** | 80 A | 1,000 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (380V)** | 120 A | 1,000 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (380V)** | 160 A | 1,000 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (380V)** | 240 A | 1,000 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With Yaskawa Solectria Solar: SGI 500XTM {380V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Yaskawa Solectria Solar: SGI 500XTM {380V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 545.0-820.0 V MPPT and 820.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 17 to 19 panels | 8.36 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 19 to 20 panels | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Yaskawa Solectria Solar: SGI 500XTM {380V}?

Four alternative CEC inverters matched to Yaskawa Solectria Solar: SGI 500XTM {380V} (507,000 W AC), led by EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**EPC Power Corp: 50-200100 {720V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-200100-720v/) EPC Power Corp | 561,806 W | +54806 W | 720.0 V | 1500.0 V | 98.58% |
| [**ABB: PVS-175-TL-POWER-MODULE-1-US {800V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-175-tl-power-module-1-us-800v/) ABB | 179,574 W | -327426 W | 800.0 V | 1200.0 V | 97.39% |
| [**LS Energy Solutions LLC: PBE-6140-R61-1A0-1000 {600V}**](https://epri-peac.com/solar-equipment/inverters/ls-energy-solutions-llc/ls-energy-solutions-llc-pbe-6140-r61-1a0-1000-600v/) LS Energy Solutions LLC | 139,449 W | -367551 W | 600.0 V | 1350.0 V | 98.27% |
| [**JingTsing Technology Ltd: JTES-PCS125K-1000/480-L03C1 {480V}**](https://epri-peac.com/solar-equipment/inverters/jingtsing-technology-ltd/jingtsing-technology-ltd-jtes-pcs125k-1000-480-l03c1-480v/) JingTsing Technology Ltd | 127,819 W | -379181 W | 480.0 V | 950.0 V | 98.0% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Yaskawa Solectria Solar: SGI 500XTM {380V}?

Check Yaskawa Solectria Solar: SGI 500XTM {380V} (507,000 W AC, 1,000 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 380 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (380V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Yaskawa Solectria Solar: SGI 500XTM {380V}.

### Yaskawa Solectria Solar: SGI 500XTM {380V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,000 A OCPD breaker (770.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.01%) and MPPT window (545-820 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Yaskawa Solectria Solar: SGI 500XTM {380V} by Yaskawa Solectria Solar covering breaker sizing, MPPT limits, and 380 V, 3-phase interconnection.

### What breaker and wire size does Yaskawa Solectria Solar: SGI 500XTM {380V} require?

At 507,000 W continuous AC (380 V, 3-phase), continuous current is 770.3 A; 125% NEC 690.8/705.12 sizing requires a 1,000 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does Yaskawa Solectria Solar: SGI 500XTM {380V} require?

At 507,000 W AC and 380 V, 3-phase, continuous line current is 770.3 A, requiring a 1,000 A OCPD and 1,200A Bus / 1,200A Main (380V) or NEC 705.11 interconnection.

### How does Yaskawa Solectria Solar: SGI 500XTM {380V} compare to EPC Power Corp: 50-200100 {720V}?

Yaskawa Solectria Solar: SGI 500XTM {380V} delivers 507,000 W AC at 97.01% CEC efficiency with a 820 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 380 V, 3-phase.

## Related Pages

Explore Yaskawa Solectria Solar hardware, EPC Power Corp: 50-200100 {720V}, utility rates, and NEC 705.12 sizing calculators alongside Yaskawa Solectria Solar: SGI 500XTM {380V}.

[All Yaskawa Solectria Solar Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/yaskawa-solectria-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Yaskawa Solectria Solar

- [All Yaskawa Solectria Solar Specs](https://epri-peac.com/solar-equipment/brands/yaskawa-solectria-solar/)
- [Yaskawa Solectria Solar: XGI 1500-1MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-1mw-600-600v/)
- [Yaskawa Solectria Solar: XGI 1500-099MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-099mw-600-600v/)
- [Yaskawa Solectria Solar: XGI 1500-085MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-085mw-600-600v/)
- [Yaskawa Solectria Solar: SGI 750XTM {380V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-sgi-750xtm-380v/)
- [Yaskawa Solectria Solar: XGI 1500-075MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-075mw-600-600v/)