title: "Yaskawa Solectria Solar Inverter (20,000W)"
url: https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-pvi20tl-480-r-480v/
description: "CEC specs for Yaskawa Solectria Solar: PVI20TL-480-R {480V}: 20,000W AC, 480V, 35A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Yaskawa Solectria Solar: PVI20TL-480-R {480V} — CEC Inverter Specifications

Manufacturer: [**Yaskawa Solectria Solar**](https://epri-peac.com/solar-equipment/brands/yaskawa-solectria-solar/) Registry: **CEC Verified Engineering Specification**

Yaskawa Solectria Solar: PVI20TL-480-R {480V} outputs 20,000 W AC at 480 V, 3-phase (24.1 A continuous, 35 A OCPD), ranking #404 of 2,343 CEC inverters at 97.86% efficiency with a 560-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 20,000 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 35 A (8 AWG Cu)

- **CEC Efficiency** : 97.86%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Yaskawa Solectria Solar: PVI20TL-480-R {480V} Compare Against Peer CEC Listings?

CEC efficiency rank (#404), 560-850 V MPPT tracking, and panel fit for Yaskawa Solectria Solar: PVI20TL-480-R {480V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Yaskawa Solectria Solar: PVI20TL-480-R {480V} from Yaskawa Solectria Solar outputs 24.1 A continuous AC at 480 V, 3-phase (20,000 W AC, rank #631). Paired with 8 AWG Cu conductors and a 35 A OCPD, its 97.86% CEC efficiency compares closely with Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (20,000 W). Keep NEC 690.7 winter string Voc below 850 V DC.

## Where Does Yaskawa Solectria Solar: PVI20TL-480-R {480V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Yaskawa Solectria Solar: PVI20TL-480-R {480V} at 20,000 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Dataset Percentiles Define Yaskawa Solectria Solar: PVI20TL-480-R {480V}?

Dataset percentiles comparing Yaskawa Solectria Solar: PVI20TL-480-R {480V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for Yaskawa Solectria Solar: PVI20TL-480-R {480V}?

Engineering highlights for Yaskawa Solectria Solar: PVI20TL-480-R {480V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #404 / 2,343

### 97.86% CEC Weighted Efficiency

-0.16 pts vs the 98.02% 480 V median; overall power rank #631 (20,000 W, top 27.2%; higher than 72.8% of peers).

NEC 705.12 Check

### 35 A Required Backfeed OCPD

125% x 24.1 A = 30.1 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 560 V - 850 V (Max 850 V DC)

Tracking span of 290.0 V; listed since 2021-04-12 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 20000.0W / 480 V 3-phase -> 24.1 A | Breaker >= 1.25 * 24.1 = 30.1 A -> 35 A

CEC Inverters.csv for Yaskawa Solectria Solar: PVI20TL-480-R {480V}: Paco=20000.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=97.86%.

**Result:** Min 35 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Yaskawa Solectria Solar: PVI20TL-480-R {480V}?

California Energy Commission Solar Equipment List parameters for Yaskawa Solectria Solar: PVI20TL-480-R {480V} (grid-tied PV inverter) interconnection. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Yaskawa Solectria Solar: PVI20TL-480-R {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 20,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 850 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 560 V - 850 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 27.806 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.86% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2021-04-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Yaskawa Solectria Solar: PVI20TL-480-R {480V} (480 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Yaskawa Solectria Solar: PVI20TL-480-R {480V} (35 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Evaluates Yaskawa Solectria Solar: PVI20TL-480-R {480V} (35 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 35 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (480V)** | 80 A | 35 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (480V)** | 120 A | 35 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (480V)** | 160 A | 35 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 35 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Yaskawa Solectria Solar: PVI20TL-480-R {480V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Yaskawa Solectria Solar: PVI20TL-480-R {480V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sampled CEC PV modules aligned within 560.0-850.0 V MPPT and 850.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 14 to 15 panels | 8.85 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 17 to 20 panels | 8.8 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 17 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 20 panels (fixed) | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Yaskawa Solectria Solar: PVI20TL-480-R {480V}?

Four alternative CEC inverters matched to Yaskawa Solectria Solar: PVI20TL-480-R {480V} (20,000 W AC), led by Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-sca20ktl-do-r-us-480-480v/) Chint Power Systems America | 20,000 W | Tie (0 W) | 480.0 V | 850.0 V | 97.86% |
| [**Fronius International GmbH: Fronius Symo 200-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-200-3-480-480v/) Fronius International GmbH | 20,000 W | Tie (0 W) | 480.0 V | 800.0 V | 97.72% |
| [**Fronius International GmbH: Fronius Symo Advanced 200-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-200-3-480-480v/) Fronius International GmbH | 20,227 W | +227 W | 480.0 V | 800.0 V | 97.69% |
| [**Fronius International GmbH: Fronius Symo Advanced 200-3 480 Lite {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-200-3-480-lite-480v/) Fronius International GmbH | 20,227 W | +227 W | 480.0 V | 800.0 V | 97.69% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Yaskawa Solectria Solar: PVI20TL-480-R {480V}?

Check Yaskawa Solectria Solar: PVI20TL-480-R {480V} (20,000 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Yaskawa Solectria Solar: PVI20TL-480-R {480V}.

### Yaskawa Solectria Solar: PVI20TL-480-R {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.1 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.86%) and MPPT window (560-850 V) directly against Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} (20,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Yaskawa Solectria Solar: PVI20TL-480-R {480V} by Yaskawa Solectria Solar covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does Yaskawa Solectria Solar: PVI20TL-480-R {480V} require?

At 20,000 W continuous AC (480 V, 3-phase), continuous current is 24.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Yaskawa Solectria Solar: PVI20TL-480-R {480V} require?

At 20,000 W AC and 480 V, 3-phase, continuous line current is 24.1 A, requiring a 35 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does Yaskawa Solectria Solar: PVI20TL-480-R {480V} compare to Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}?

Yaskawa Solectria Solar: PVI20TL-480-R {480V} delivers 20,000 W AC at 97.86% CEC efficiency with a 850 V DC ceiling, while Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V} outputs 20,000 W at 480 V, 3-phase.

## Related Pages

Explore Yaskawa Solectria Solar hardware, Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V}, utility rates, and NEC 705.12 sizing calculators alongside Yaskawa Solectria Solar: PVI20TL-480-R {480V}.

[All Yaskawa Solectria Solar Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/yaskawa-solectria-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Yaskawa Solectria Solar

- [All Yaskawa Solectria Solar Specs](https://epri-peac.com/solar-equipment/brands/yaskawa-solectria-solar/)
- [Yaskawa Solectria Solar: XGI 1500-1MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-1mw-600-600v/)
- [Yaskawa Solectria Solar: XGI 1500-099MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-099mw-600-600v/)
- [Yaskawa Solectria Solar: XGI 1500-085MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-085mw-600-600v/)
- [Yaskawa Solectria Solar: SGI 750XTM {380V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-sgi-750xtm-380v/)
- [Yaskawa Solectria Solar: XGI 1500-075MW-600 {600V}](https://epri-peac.com/solar-equipment/inverters/yaskawa-solectria-solar/yaskawa-solectria-solar-xgi-1500-075mw-600-600v/)