Manufacturer: [**WSTECH GmbH**](https://epri-peac.com/solar-equipment/brands/wstech-gmbh/) Registry: **CEC Verified Engineering Specification**

WSTECH GmbH: APS870-PV-1-480-5 {480V} outputs 872,029 W AC at 480 V, 3-phase (1048.9 A continuous, 1,350 A OCPD), ranking #529 of 2,343 CEC inverters at 97.55% efficiency with a 770-1,470 V MPPT window and 1,470 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 872,029 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 1,350 A (parallel Cu feeders)

- **CEC Efficiency** : 97.55%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WSTECH GmbH: APS870-PV-1-480-5 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for WSTECH GmbH: APS870-PV-1-480-5 {480V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rated at 872,029 W AC (1048.9 A continuous), WSTECH GmbH: APS870-PV-1-480-5 {480V} ranks #529 of 2,343 CEC units at 97.55% efficiency (-0.47 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 1,350 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,470 V DC at record local winter lows.

## Where Does WSTECH GmbH: APS870-PV-1-480-5 {480V} Fall Across Listed CEC Models?

Marks WSTECH GmbH: APS870-PV-1-480-5 {480V} (872,029 W AC) across the California Energy Commission inverter AC capacity distribution. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Dataset Percentiles Define WSTECH GmbH: APS870-PV-1-480-5 {480V}?

Benchmarks WSTECH GmbH: APS870-PV-1-480-5 {480V} continuous AC output, 97.55% CEC weighted efficiency, and 1,350 A OCPD breaker demand.

## What Do the Dataset Ranks Show for WSTECH GmbH: APS870-PV-1-480-5 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining WSTECH GmbH: APS870-PV-1-480-5 {480V} by WSTECH GmbH. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Eff #529 / 2,343

### 97.55% CEC Weighted Efficiency

-0.47 pts vs the 98.02% 480 V median; overall power rank #173 (872,029 W, top 7.4%; higher than 92.6% of peers).

NEC 705.12 Check

### 1,350 A Required Backfeed OCPD

125% x 1048.9 A = 1311.1 A -> 1,350 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 770 V - 1,470 V (Max 1,470 V DC)

Tracking span of 700.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 872029.0W / 480 V 3-phase -> 1048.9 A | Breaker >= 1.25 * 1048.9 = 1311.1 A -> 1,350 A

CEC Inverters.csv for WSTECH GmbH: APS870-PV-1-480-5 {480V}: Paco=872029.0 W, Vac=480 V, Vdcmax=1470.0 V, Eff=97.55%.

**Result:** Min 1,350 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (480V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for WSTECH GmbH: APS870-PV-1-480-5 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for WSTECH GmbH: APS870-PV-1-480-5 {480V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for WSTECH GmbH: APS870-PV-1-480-5 {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 872,029 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,470 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 770 V - 1,470 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 893.886 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.55% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to WSTECH GmbH: APS870-PV-1-480-5 {480V} (480 V, 3-phase)?

Evaluates WSTECH GmbH: APS870-PV-1-480-5 {480V} (1,350 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates WSTECH GmbH: APS870-PV-1-480-5 {480V} (1350 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 1,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (480V)** | 80 A | 1,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (480V)** | 120 A | 1,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (480V)** | 160 A | 1,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 1,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With WSTECH GmbH: APS870-PV-1-480-5 {480V}?

Sample PV string lengths aligned within 770-1,470 V MPPT and 1,470 V DC max at -10 C. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 770.0-1470.0 V MPPT and 1470.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 18 to 26 panels | 15.34 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 23 to 34 panels | 14.96 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 23 to 32 panels | 13.6 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 27 to 36 panels | 7.2 kW |

## Which Competing Grid-Support Inverters Compare to WSTECH GmbH: APS870-PV-1-480-5 {480V}?

Competing CEC grid-support inverters near 872,029 W AC and 480 V, 3-phase, led by DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {480V}**](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1250-gen5-480v/) DYNAPOWER COMPANY LLC | 799,592 W | -72437 W | 480.0 V | 1500.0 V | 97.96% |
| [**EPC Power Corp: 50-100100 {480V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100100-480v/) EPC Power Corp | 1,036,840 W | +164811 W | 480.0 V | 1250.0 V | 95.42% |
| [**EPC Power Corp: 50-100181 {480V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100181-480v/) EPC Power Corp | 1,044,200 W | +172171 W | 480.0 V | 1500.0 V | 97.49% |
| [**DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}**](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1500-gen4-480v/) DYNAPOWER COMPANY LLC | 1,199,640 W | +327611 W | 480.0 V | 1500.0 V | 96.13% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for WSTECH GmbH: APS870-PV-1-480-5 {480V}?

Check WSTECH GmbH: APS870-PV-1-480-5 {480V} (872,029 W AC, 1,350 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,470 V DC on WSTECH GmbH: APS870-PV-1-480-5 {480V}.

### WSTECH GmbH: APS870-PV-1-480-5 {480V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,350 A OCPD breaker (1048.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.55%) and MPPT window (770-1,470 V) directly against DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {480V} (799,592 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for WSTECH GmbH: APS870-PV-1-480-5 {480V} by WSTECH GmbH covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does WSTECH GmbH: APS870-PV-1-480-5 {480V} require?

At 872,029 W continuous AC (480 V, 3-phase), continuous current is 1048.9 A; 125% NEC 690.8/705.12 sizing requires a 1,350 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does WSTECH GmbH: APS870-PV-1-480-5 {480V} require?

At 872,029 W AC and 480 V, 3-phase, continuous line current is 1048.9 A, requiring a 1,350 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does WSTECH GmbH: APS870-PV-1-480-5 {480V} compare to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {480V}?

WSTECH GmbH: APS870-PV-1-480-5 {480V} delivers 872,029 W AC at 97.55% CEC efficiency with a 1,470 V DC ceiling, while DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {480V} outputs 799,592 W at 480 V, 3-phase.

## Related Pages

Explore WSTECH GmbH hardware, DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {480V}, utility rates, and NEC 705.12 sizing calculators alongside WSTECH GmbH: APS870-PV-1-480-5 {480V}.

[All WSTECH GmbH Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/wstech-gmbh/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WSTECH GmbH

- [All WSTECH GmbH Specs](https://epri-peac.com/solar-equipment/brands/wstech-gmbh/)
- [WSTECH GmbH: APS1740-ES-2-480-5 {480V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1740-es-2-480-5-480v/)
- [WSTECH GmbH: APS1740-PV-2-480-5 {480V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1740-pv-2-480-5-480v/)
- [WSTECH GmbH: APS1600-ES-2-440-5 {440V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1600-es-2-440-5-440v/)
- [WSTECH GmbH: APS1600-PV-2-440-5 {440V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1600-pv-2-440-5-440v/)
- [WSTECH GmbH: APS870-ES-1-480-5 {480V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps870-es-1-480-5-480v/)