---
title: "WSTECH GmbH: APS1600-PV-2-440-5 Inverter (1,626,952W)"
url: https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1600-pv-2-440-5-440v/
description: "CEC specs for WSTECH GmbH: APS1600-PV-2-440-5 {440V}: 1,626,952W AC, 440V, 2700A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# WSTECH GmbH: APS1600-PV-2-440-5 {440V} — CEC Inverter Specifications

Manufacturer: [**WSTECH GmbH**](https://epri-peac.com/solar-equipment/brands/wstech-gmbh/) Registry: **CEC Verified Engineering Specification**

WSTECH GmbH: APS1600-PV-2-440-5 {440V} outputs 1,626,952 W AC at 440 V, 3-phase (2134.9 A continuous, 2,700 A OCPD), ranking #550 of 2,343 CEC inverters at 97.49% efficiency with a 648-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,626,952 W

- **AC Voltage** : 440 V, 3-phase

- **Min PV Breaker** : 2,700 A (parallel Cu feeders)

- **CEC Efficiency** : 97.49%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WSTECH GmbH: APS1600-PV-2-440-5 {440V} Compare Against Peer CEC Listings?

How WSTECH GmbH WSTECH GmbH: APS1600-PV-2-440-5 {440V} compares on 97.49% efficiency, MPPT span, and 120% busbar interconnection. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

With a 648-1,500 V MPPT tracking band and 1,500 V DC ceiling, WSTECH GmbH: APS1600-PV-2-440-5 {440V} handles 1,626,952 W continuous AC (577,299 W above the 1,049,653 W 440 V median). Commercial 440 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (440V) or NEC 705.11 supply-side tap. Installers comparing WSTECH GmbH against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

## Where Does WSTECH GmbH: APS1600-PV-2-440-5 {440V} Fall Across Listed CEC Models?

Position of WSTECH GmbH: APS1600-PV-2-440-5 {440V} (1,626,952 W AC) relative to the 7,680 W CEC median inverter. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Dataset Percentiles Define WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Percentile placement of WSTECH GmbH: APS1600-PV-2-440-5 {440V} across AC power class, conversion efficiency, and backfeed breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Do the Dataset Ranks Show for WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for WSTECH GmbH: APS1600-PV-2-440-5 {440V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #550 / 2,343

### 97.49% CEC Weighted Efficiency

+0.02 pts vs the 97.47% 440 V median; overall power rank #124 (1,626,952 W, top 5.3%; higher than 94.7% of peers).

NEC 705.12 Check

### 2,700 A Required Backfeed OCPD

125% x 2134.9 A = 2668.6 A -> 2,700 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 648 V - 1,500 V (Max 1,500 V DC)

Tracking span of 852.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 440 V, 3-phase switchgear (200A Bus / 200A Main (440V) to 1,200A Bus / 1,200A Main (440V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1626952.0W / 440 V 3-phase -> 2134.9 A | Breaker >= 1.25 * 2134.9 = 2668.6 A -> 2,700 A

CEC Inverters.csv for WSTECH GmbH: APS1600-PV-2-440-5 {440V}: Paco=1626952.0 W, Vac=440 V, Vdcmax=1500.0 V, Eff=97.49%.

**Result:** Min 2,700 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (440V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for WSTECH GmbH: APS1600-PV-2-440-5 {440V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for WSTECH GmbH: APS1600-PV-2-440-5 {440V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,626,952 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 440 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 648 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 1668.84 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.49% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to WSTECH GmbH: APS1600-PV-2-440-5 {440V} (440 V, 3-phase)?

Check whether WSTECH GmbH: APS1600-PV-2-440-5 {440V} (2,700 A breaker) fits without main breaker derate or supply-side taps. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Evaluates WSTECH GmbH: APS1600-PV-2-440-5 {440V} (2700 A required OCPD at 440 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (440V)** | 40 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (440V)** | 80 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (440V)** | 120 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (440V)** | 160 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (440V)** | 240 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Verified cold-weather (-10 C) series module counts matched to WSTECH GmbH: APS1600-PV-2-440-5 {440V}'s 1,500 V DC ceiling.

Sampled CEC PV modules aligned within 648.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 16 to 26 panels | 15.34 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 20 to 35 panels | 15.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 19 to 33 panels | 14.03 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 23 to 36 panels | 7.2 kW |

## Which Competing Grid-Support Inverters Compare to WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Alternative CEC inverters comparable to WSTECH GmbH: APS1600-PV-2-440-5 {440V}, including Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W) at 440 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) Schneider Electric USA Inc | 1,666,000 W | +39048 W | 575.0 V | 1200.0 V | 97.54% |
| [**SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1725-ha-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,726,700 W | +99748 W | 690.0 V | 1500.0 V | 98.32% |
| [**Power Electronics: FS2250CU15O3 {600V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs2250cu15o3-600v/) Power Electronics | 2,420,370 W | +793418 W | 600.0 V | 1200.0 V | 97.82% |
| [**INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}**](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c480-480v/) INGETEAM POWER TECHNOLOGY SA | 2,467,620 W | +840668 W | 480.0 V | 1300.0 V | 96.63% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Check WSTECH GmbH: APS1600-PV-2-440-5 {440V} (1,626,952 W AC, 2,700 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 440 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (440V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on WSTECH GmbH: APS1600-PV-2-440-5 {440V}.

### WSTECH GmbH: APS1600-PV-2-440-5 {440V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,700 A OCPD breaker (2134.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.49%) and MPPT window (648-1,500 V) directly against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for WSTECH GmbH: APS1600-PV-2-440-5 {440V} by WSTECH GmbH covering breaker sizing, MPPT limits, and 440 V, 3-phase interconnection.

### What breaker and wire size does WSTECH GmbH: APS1600-PV-2-440-5 {440V} require?

At 1,626,952 W continuous AC (440 V, 3-phase), continuous current is 2134.9 A; 125% NEC 690.8/705.12 sizing requires a 2,700 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does WSTECH GmbH: APS1600-PV-2-440-5 {440V} require?

At 1,626,952 W AC and 440 V, 3-phase, continuous line current is 2134.9 A, requiring a 2,700 A OCPD and 1,200A Bus / 1,200A Main (440V) or NEC 705.11 interconnection.

### How does WSTECH GmbH: APS1600-PV-2-440-5 {440V} compare to Schneider Electric USA Inc: CS1666-3-NA {575V}?

WSTECH GmbH: APS1600-PV-2-440-5 {440V} delivers 1,626,952 W AC at 97.49% CEC efficiency with a 1,500 V DC ceiling, while Schneider Electric USA Inc: CS1666-3-NA {575V} outputs 1,666,000 W at 440 V, 3-phase.

## Related Pages

Explore WSTECH GmbH hardware, Schneider Electric USA Inc: CS1666-3-NA {575V}, utility rates, and NEC 705.12 sizing calculators alongside WSTECH GmbH: APS1600-PV-2-440-5 {440V}.

[All WSTECH GmbH Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/wstech-gmbh/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WSTECH GmbH

- [All WSTECH GmbH Specs](https://epri-peac.com/solar-equipment/brands/wstech-gmbh/)
- [WSTECH GmbH: APS1740-ES-2-480-5 {480V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1740-es-2-480-5-480v/)
- [WSTECH GmbH: APS1740-PV-2-480-5 {480V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1740-pv-2-480-5-480v/)
- [WSTECH GmbH: APS1600-ES-2-440-5 {440V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps1600-es-2-440-5-440v/)
- [WSTECH GmbH: APS870-ES-1-480-5 {480V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps870-es-1-480-5-480v/)
- [WSTECH GmbH: APS870-PV-1-480-5 {480V}](https://epri-peac.com/solar-equipment/inverters/wstech-gmbh/wstech-gmbh-aps870-pv-1-480-5-480v/)
