title: "Univix Power Solutions: UVX16LNA Inverter (16,000W)"
url: https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx16lna-240v/
description: "CEC specs for Univix Power Solutions: UVX16LNA {240V}: 16,000W AC, 240V, 90A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Univix Power Solutions: UVX16LNA {240V} — CEC Inverter Specifications

Manufacturer: [**Univix Power Solutions**](https://epri-peac.com/solar-equipment/brands/univix-power-solutions/) Registry: **CEC Verified Engineering Specification**

Univix Power Solutions: UVX16LNA {240V} outputs 16,000 W AC at 240 V (66.7 A continuous, 90 A OCPD), ranking #1,808 of 2,343 CEC inverters at 96.26% efficiency with a 220-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 16,000 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 90 A (3 AWG Cu)

- **CEC Efficiency** : 96.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Univix Power Solutions: UVX16LNA {240V} Compare Against Peer CEC Listings?

How Univix Power Solutions Univix Power Solutions: UVX16LNA {240V} compares on 96.26% efficiency, MPPT span, and 120% busbar interconnection.

With a 220-430 V MPPT tracking band and 430 V DC ceiling, Univix Power Solutions: UVX16LNA {240V} handles 16,000 W continuous AC (10,224 W above the 5,776 W 240 V median). Its 90 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Installers comparing Univix Power Solutions against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

## Where Does Univix Power Solutions: UVX16LNA {240V} Fall Across Listed CEC Models?

Position of Univix Power Solutions: UVX16LNA {240V} (16,000 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Univix Power Solutions: UVX16LNA {240V}?

Percentile placement of Univix Power Solutions: UVX16LNA {240V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Univix Power Solutions: UVX16LNA {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Univix Power Solutions: UVX16LNA {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Eff #1,808 / 2,343

### 96.26% CEC Weighted Efficiency

-0.42 pts vs the 96.68% 240 V median; overall power rank #659 (16,000 W, top 28.1%; higher than 71.9% of peers).

NEC 705.12 Check

### 90 A Required Backfeed OCPD

125% x 66.7 A = 83.4 A -> 90 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

### 220 V - 430 V (Max 430 V DC)

Tracking span of 210.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 16000.0W / 240 V -> 66.7 A | Breaker >= 1.25 * 66.7 = 83.4 A -> 90 A

CEC Inverters.csv for Univix Power Solutions: UVX16LNA {240V}: Paco=16000.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=96.26%.

**Result:** Min 90 A breaker & 3 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Univix Power Solutions: UVX16LNA {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Univix Power Solutions: UVX16LNA {240V}.

Official California Energy Commission (NREL SAM) test parameters for Univix Power Solutions: UVX16LNA {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 16,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 430 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 220 V - 430 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 46.1701 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.26% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Univix Power Solutions: UVX16LNA {240V}?

Check whether Univix Power Solutions: UVX16LNA {240V} (90 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Univix Power Solutions: UVX16LNA {240V} (90 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 90 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 90 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 90 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 90 A | Needs Derate / Tap 705.11 |
| **225A Bus / 200A Main** | 70 A | 90 A | Needs Derate / Tap 705.11 |

## Which CEC PV Module Strings Pair With Univix Power Solutions: UVX16LNA {240V}?

Verified cold-weather (-10 C) series module counts matched to Univix Power Solutions: UVX16LNA {240V}'s 430 V DC ceiling.

Sampled CEC PV modules aligned within 220.0-430.0 V MPPT and 430.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 7 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 7 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 8 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to Univix Power Solutions: UVX16LNA {240V}?

Alternative CEC inverters comparable to Univix Power Solutions: UVX16LNA {240V}, including Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Amensolar Ess Co Ltd: N3H-X16US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x16us-240v/) Amensolar Ess Co Ltd | 16,199 W | +199 W | 240.0 V | 430.0 V | 96.25% |
| [**Amensolar Ess Co Ltd: N3H-X12US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x12us-240v/) Amensolar Ess Co Ltd | 12,214 W | -3786 W | 240.0 V | 430.0 V | 96.17% |
| [**Chint Power Systems America: CPS ECH12KTL/US {240V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-240v/) Chint Power Systems America | 11,990 W | -4010 W | 240.0 V | 480.0 V | 96.59% |
| [**Delta Electronics: S12_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-s12-bdi-240v/) Delta Electronics | 11,589 W | -4411 W | 240.0 V | 480.0 V | 96.99% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Univix Power Solutions: UVX16LNA {240V}?

Check Univix Power Solutions: UVX16LNA {240V} (16,000 W AC, 90 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 90 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on Univix Power Solutions: UVX16LNA {240V}.

### Univix Power Solutions: UVX16LNA {240V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 90 A OCPD breaker (66.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.26%) and MPPT window (220-430 V) directly against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Univix Power Solutions: UVX16LNA {240V} by Univix Power Solutions covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Univix Power Solutions: UVX16LNA {240V} require?

At 16,000 W continuous AC (240 V), continuous current is 66.7 A; 125% NEC 690.8/705.12 sizing requires a 90 A breaker and 3 AWG Cu (75 C) wire.

### Does Univix Power Solutions: UVX16LNA {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 90 A at 240 V means Needs Derate / Tap 705.11.

### How does Univix Power Solutions: UVX16LNA {240V} compare to Amensolar Ess Co Ltd: N3H-X16US {240V}?

Univix Power Solutions: UVX16LNA {240V} delivers 16,000 W AC at 96.26% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X16US {240V} outputs 16,199 W at 240 V.

## Related Pages

Explore Univix Power Solutions hardware, Amensolar Ess Co Ltd: N3H-X16US {240V}, utility rates, and NEC 705.12 sizing calculators alongside Univix Power Solutions: UVX16LNA {240V}.

[All Univix Power Solutions Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/univix-power-solutions/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Univix Power Solutions

- [All Univix Power Solutions Specs](https://epri-peac.com/solar-equipment/brands/univix-power-solutions/)
- [Univix Power Solutions: UVX12KLNA {240V}](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx12klna-240v/)
- [Univix Power Solutions: UVX10KLNA {240V}](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx10klna-240v/)
- [Univix Power Solutions: UVX8KLNA {240V}](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx8klna-240v/)
- [Univix Power Solutions: UVX76KLNA {240V}](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx76klna-240v/)
- [Univix Power Solutions: UVX6KLNA {240V}](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx6klna-240v/)