title: "Trystar LLC: OZPCS-RS40-Fxx {208V} Inverter (17,515W)"
url: https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-fxx-208v/
description: "CEC specs for Trystar LLC: OZPCS-RS40-Fxx {208V}: 17,515W AC, 208V, 70A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Trystar LLC: OZPCS-RS40-Fxx {208V} — CEC Inverter Specifications

Manufacturer: [**Trystar LLC**](https://epri-peac.com/solar-equipment/brands/trystar-llc/) Registry: **CEC Verified Engineering Specification**

Trystar LLC: OZPCS-RS40-Fxx {208V} outputs 17,515 W AC at 208 V, 3-phase (48.6 A continuous, 70 A OCPD), ranking #2,318 of 2,343 CEC inverters at 93.86% efficiency with a 550-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 17,515 W

- **AC Voltage** : 208 V, 3-phase

- **Min PV Breaker** : 70 A (4 AWG Cu)

- **CEC Efficiency** : 93.86%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trystar LLC: OZPCS-RS40-Fxx {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,318), 550-820 V MPPT tracking, and panel fit for Trystar LLC: OZPCS-RS40-Fxx {208V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Operating at 208 V, 3-phase, Trystar LLC: OZPCS-RS40-Fxx {208V} converts DC array energy at 93.86% CEC weighted efficiency (below overall CEC median; higher than 1.1% of peers) with a 820 V max DC input and 26.6574 A max input current for NEC 690.7 string safety. Compare this 17,515 W grid-tied PV inverter directly with EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.

## Where Does Trystar LLC: OZPCS-RS40-Fxx {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Trystar LLC: OZPCS-RS40-Fxx {208V} at 17,515 W continuous AC output. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define Trystar LLC: OZPCS-RS40-Fxx {208V}?

Dataset percentiles comparing Trystar LLC: OZPCS-RS40-Fxx {208V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS40-Fxx {208V}?

Engineering highlights for Trystar LLC: OZPCS-RS40-Fxx {208V} covering efficiency, 4 AWG Cu feeder, and panel compatibility. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #2,318 / 2,343

### 93.86% CEC Weighted Efficiency

-2.55 pts vs the 96.41% 208 V median; overall power rank #640 (17,515 W, top 27.3%; higher than 72.7% of peers).

NEC 705.12 Check

### 70 A Required Backfeed OCPD

125% x 48.6 A = 60.8 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 550 V - 820 V (Max 820 V DC)

Tracking span of 270.0 V; listed since 2024-04-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 17515.0W / 208 V 3-phase -> 48.6 A | Breaker >= 1.25 * 48.6 = 60.8 A -> 70 A

CEC Inverters.csv for Trystar LLC: OZPCS-RS40-Fxx {208V}: Paco=17515.0 W, Vac=208 V, Vdcmax=820.0 V, Eff=93.86%.

**Result:** Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS40-Fxx {208V}?

California Energy Commission Solar Equipment List parameters for Trystar LLC: OZPCS-RS40-Fxx {208V} (grid-tied PV inverter) interconnection. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Trystar LLC: OZPCS-RS40-Fxx {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 17,515 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 820 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 550 V - 820 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 26.6574 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 93.86% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-04-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Trystar LLC: OZPCS-RS40-Fxx {208V} (208 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Trystar LLC: OZPCS-RS40-Fxx {208V} (70 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates Trystar LLC: OZPCS-RS40-Fxx {208V} (70 A required OCPD at 208 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 70 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 70 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 70 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 70 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 70 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS40-Fxx {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Trystar LLC: OZPCS-RS40-Fxx {208V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 550.0-820.0 V MPPT and 820.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 17 to 19 panels | 8.36 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 20 panels (fixed) | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS40-Fxx {208V}?

Four alternative CEC inverters matched to Trystar LLC: OZPCS-RS40-Fxx {208V} (17,515 W AC), led by EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-iv-16000-hyb-aw-fx-xx-208v/) EG4 Electronics LLC | 13,899 W | -3616 W | 208.0 V | 440.0 V | 96.46% |
| [**Chint Power Systems America: CPS ECH12KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-208v/) Chint Power Systems America | 12,000 W | -5515 W | 208.0 V | 480.0 V | 96.63% |
| [**EcoFlow Inc: EF-PCS-24 {208V 115kW}**](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-115kw/) EcoFlow Inc | 11,444 W | -6071 W | 208.0 V | 480.0 V | 96.52% |
| [**Chint Power Systems America: CPS ECH114KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech114ktl-us-208v/) Chint Power Systems America | 11,350 W | -6165 W | 208.0 V | 480.0 V | 96.63% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS40-Fxx {208V}?

Check Trystar LLC: OZPCS-RS40-Fxx {208V} (17,515 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Trystar LLC: OZPCS-RS40-Fxx {208V}.

### Trystar LLC: OZPCS-RS40-Fxx {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (48.6 A continuous).

### Alternative Inverter Comparison

Compare efficiency (93.86%) and MPPT window (550-820 V) directly against EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Trystar LLC: OZPCS-RS40-Fxx {208V} by Trystar LLC covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

### What breaker and wire size does Trystar LLC: OZPCS-RS40-Fxx {208V} require?

At 17,515 W continuous AC (208 V, 3-phase), continuous current is 48.6 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS40-Fxx {208V} require?

At 17,515 W AC and 208 V, 3-phase, continuous line current is 48.6 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Trystar LLC: OZPCS-RS40-Fxx {208V} compare to EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}?

Trystar LLC: OZPCS-RS40-Fxx {208V} delivers 17,515 W AC at 93.86% CEC efficiency with a 820 V DC ceiling, while EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} outputs 13,899 W at 208 V, 3-phase.

## Related Pages

Explore Trystar LLC hardware, EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}, utility rates, and NEC 705.12 sizing calculators alongside Trystar LLC: OZPCS-RS40-Fxx {208V}.

[All Trystar LLC Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/trystar-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trystar LLC

- [All Trystar LLC Specs](https://epri-peac.com/solar-equipment/brands/trystar-llc/)
- [Trystar LLC: OZPCS-RS40-Bxx {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-bxx-480v/)
- [Trystar LLC: OZPCS-RS40-Fxx {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-fxx-480v/)
- [Trystar LLC: OZPCS-EP40-000 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-ep40-000-480v/)
- [Trystar LLC: OZPCS-RS40-BB1 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-bb1-480v/)
- [Trystar LLC: OZPCS-RS40-FB1 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-fb1-480v/)