title: "Trystar LLC: OZPCS-RS40-Bxx {480V} Inverter (39,913W)"
url: https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-bxx-480v/
description: "CEC specs for Trystar LLC: OZPCS-RS40-Bxx {480V}: 39,913W AC, 480V, 60A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Trystar LLC: OZPCS-RS40-Bxx {480V} — CEC Inverter Specifications

Manufacturer: [**Trystar LLC**](https://epri-peac.com/solar-equipment/brands/trystar-llc/) Registry: **CEC Verified Engineering Specification**

Trystar LLC: OZPCS-RS40-Bxx {480V} outputs 39,913 W AC at 480 V, 3-phase (48.0 A continuous, 60 A OCPD), ranking #918 of 2,343 CEC inverters at 97.07% efficiency with a 550-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 39,913 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 60 A (6 AWG Cu)

- **CEC Efficiency** : 97.07%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trystar LLC: OZPCS-RS40-Bxx {480V} Compare Against Peer CEC Listings?

How Trystar LLC Trystar LLC: OZPCS-RS40-Bxx {480V} compares on 97.07% efficiency, MPPT span, and 120% busbar interconnection. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Trystar LLC certifies Trystar LLC: OZPCS-RS40-Bxx {480V} (grid-tied PV inverter, listed since 2024-04-02) at 39,913 W AC (10,087 W below the 50,000 W 480 V median). Its 820 V DC ceiling pairs with an MPPT window of 550-820 V (span 270.0 V). Under NEC 690.8/705.12, 125% sizing demands 6 AWG Cu conductors on a 60 A OCPD.

## Where Does Trystar LLC: OZPCS-RS40-Bxx {480V} Fall Across Listed CEC Models?

Position of Trystar LLC: OZPCS-RS40-Bxx {480V} (39,913 W AC) relative to the 7,680 W CEC median inverter. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define Trystar LLC: OZPCS-RS40-Bxx {480V}?

Percentile placement of Trystar LLC: OZPCS-RS40-Bxx {480V} across AC power class, conversion efficiency, and backfeed breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS40-Bxx {480V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Trystar LLC: OZPCS-RS40-Bxx {480V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Eff #918 / 2,343

### 97.07% CEC Weighted Efficiency

-0.95 pts vs the 98.02% 480 V median; overall power rank #492 (39,913 W, top 21.0%; higher than 79.0% of peers).

NEC 705.12 Check

### 60 A Required Backfeed OCPD

125% x 48.0 A = 60.0 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

### 550 V - 820 V (Max 820 V DC)

Tracking span of 270.0 V; listed since 2024-04-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 39913.0W / 480 V 3-phase -> 48.0 A | Breaker >= 1.25 * 48.0 = 60.0 A -> 60 A

CEC Inverters.csv for Trystar LLC: OZPCS-RS40-Bxx {480V}: Paco=39913.0 W, Vac=480 V, Vdcmax=820.0 V, Eff=97.07%.

**Result:** Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS40-Bxx {480V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Trystar LLC: OZPCS-RS40-Bxx {480V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Trystar LLC: OZPCS-RS40-Bxx {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 39,913 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 820 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 550 V - 820 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 58.742 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.07% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-04-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Trystar LLC: OZPCS-RS40-Bxx {480V} (480 V, 3-phase)?

Check whether Trystar LLC: OZPCS-RS40-Bxx {480V} (60 A breaker) fits without main breaker derate or supply-side taps. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates Trystar LLC: OZPCS-RS40-Bxx {480V} (60 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (480V)** | 80 A | 60 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (480V)** | 120 A | 60 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (480V)** | 160 A | 60 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 60 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS40-Bxx {480V}?

Verified cold-weather (-10 C) series module counts matched to Trystar LLC: OZPCS-RS40-Bxx {480V}'s 820 V DC ceiling.

Sampled CEC PV modules aligned within 550.0-820.0 V MPPT and 820.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 17 to 19 panels | 8.36 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 20 panels (fixed) | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS40-Bxx {480V}?

Alternative CEC inverters comparable to Trystar LLC: OZPCS-RS40-Bxx {480V}, including CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} (39,926 W) at 480 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-40k-t480gl01-ub-480v/) CSI Solar Co Ltd | 39,926 W | +13 W | 480.0 V | 800.0 V | 98.34% |
| [**Fortress Power LLC: FP-Nano-40k-N {480V}**](https://epri-peac.com/solar-equipment/inverters/fortress-power-llc/fortress-power-llc-fp-nano-40k-n-480v/) Fortress Power LLC | 39,844 W | -69 W | 480.0 V | 850.0 V | 97.38% |
| [**CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-40k-t480gl03-u-480v/) CSI Solar Co Ltd | 39,841 W | -72 W | 480.0 V | 850.0 V | 98.02% |
| [**Canadian Solar Inc: CSI-40KTL-GS {480V}**](https://epri-peac.com/solar-equipment/inverters/canadian-solar-inc/canadian-solar-inc-csi-40ktl-gs-480v/) Canadian Solar Inc | 40,000 W | +87 W | 480.0 V | 780.0 V | 98.0% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS40-Bxx {480V}?

Check Trystar LLC: OZPCS-RS40-Bxx {480V} (39,913 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Trystar LLC: OZPCS-RS40-Bxx {480V}.

### Trystar LLC: OZPCS-RS40-Bxx {480V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (48.0 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.07%) and MPPT window (550-820 V) directly against CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} (39,926 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Trystar LLC: OZPCS-RS40-Bxx {480V} by Trystar LLC covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does Trystar LLC: OZPCS-RS40-Bxx {480V} require?

At 39,913 W continuous AC (480 V, 3-phase), continuous current is 48.0 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS40-Bxx {480V} require?

At 39,913 W AC and 480 V, 3-phase, continuous line current is 48.0 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does Trystar LLC: OZPCS-RS40-Bxx {480V} compare to CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V}?

Trystar LLC: OZPCS-RS40-Bxx {480V} delivers 39,913 W AC at 97.07% CEC efficiency with a 820 V DC ceiling, while CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} outputs 39,926 W at 480 V, 3-phase.

## Related Pages

Explore Trystar LLC hardware, CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V}, utility rates, and NEC 705.12 sizing calculators alongside Trystar LLC: OZPCS-RS40-Bxx {480V}.

[All Trystar LLC Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/trystar-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trystar LLC

- [All Trystar LLC Specs](https://epri-peac.com/solar-equipment/brands/trystar-llc/)
- [Trystar LLC: OZPCS-RS40-Fxx {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-fxx-480v/)
- [Trystar LLC: OZPCS-EP40-000 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-ep40-000-480v/)
- [Trystar LLC: OZPCS-RS40-BB1 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-bb1-480v/)
- [Trystar LLC: OZPCS-RS40-FB1 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-fb1-480v/)
- [Trystar LLC: OZPCS-RS35-FB0 {208V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs35-fb0-208v/)