title: "Trystar LLC: OZPCS-RS40-Bxx {208V} Inverter (17,516W)"
url: https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-bxx-208v/
description: "CEC specs for Trystar LLC: OZPCS-RS40-Bxx {208V}: 17,516W AC, 208V, 70A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Trystar LLC: OZPCS-RS40-Bxx {208V} — CEC Inverter Specifications

Manufacturer: [**Trystar LLC**](https://epri-peac.com/solar-equipment/brands/trystar-llc/) Registry: **CEC Verified Engineering Specification**

Trystar LLC: OZPCS-RS40-Bxx {208V} outputs 17,516 W AC at 208 V, 3-phase (48.6 A continuous, 70 A OCPD), ranking #2,312 of 2,343 CEC inverters at 94.15% efficiency with a 550-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 17,516 W

- **AC Voltage** : 208 V, 3-phase

- **Min PV Breaker** : 70 A (4 AWG Cu)

- **CEC Efficiency** : 94.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trystar LLC: OZPCS-RS40-Bxx {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,312), 550-820 V MPPT tracking, and panel fit for Trystar LLC: OZPCS-RS40-Bxx {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Trystar LLC: OZPCS-RS40-Bxx {208V} from Trystar LLC outputs 48.6 A continuous AC at 208 V, 3-phase (17,516 W AC, rank #639). Paired with 4 AWG Cu conductors and a 70 A OCPD, its 94.15% CEC efficiency compares closely with EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W). Keep NEC 690.7 winter string Voc below 820 V DC.

## Where Does Trystar LLC: OZPCS-RS40-Bxx {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Trystar LLC: OZPCS-RS40-Bxx {208V} at 17,516 W continuous AC output. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define Trystar LLC: OZPCS-RS40-Bxx {208V}?

Dataset percentiles comparing Trystar LLC: OZPCS-RS40-Bxx {208V} against 2,343 certified grid-support inverters nationwide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS40-Bxx {208V}?

Engineering highlights for Trystar LLC: OZPCS-RS40-Bxx {208V} covering efficiency, 4 AWG Cu feeder, and panel compatibility. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Eff #2,312 / 2,343

### 94.15% CEC Weighted Efficiency

-2.26 pts vs the 96.41% 208 V median; overall power rank #639 (17,516 W, top 27.3%; higher than 72.7% of peers).

NEC 705.12 Check

### 70 A Required Backfeed OCPD

125% x 48.6 A = 60.8 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 550 V - 820 V (Max 820 V DC)

Tracking span of 270.0 V; listed since 2024-04-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 17516.0W / 208 V 3-phase -> 48.6 A | Breaker >= 1.25 * 48.6 = 60.8 A -> 70 A

CEC Inverters.csv for Trystar LLC: OZPCS-RS40-Bxx {208V}: Paco=17516.0 W, Vac=208 V, Vdcmax=820.0 V, Eff=94.15%.

**Result:** Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS40-Bxx {208V}?

California Energy Commission Solar Equipment List parameters for Trystar LLC: OZPCS-RS40-Bxx {208V} (grid-tied PV inverter) interconnection. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Trystar LLC: OZPCS-RS40-Bxx {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 17,516 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 820 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 550 V - 820 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 26.5776 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 94.15% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-04-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Trystar LLC: OZPCS-RS40-Bxx {208V} (208 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Trystar LLC: OZPCS-RS40-Bxx {208V} (70 A OCPD). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates Trystar LLC: OZPCS-RS40-Bxx {208V} (70 A required OCPD at 208 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 70 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 70 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 70 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 70 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 70 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS40-Bxx {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Trystar LLC: OZPCS-RS40-Bxx {208V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 550.0-820.0 V MPPT and 820.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 17 to 19 panels | 8.36 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 20 panels (fixed) | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS40-Bxx {208V}?

Four alternative CEC inverters matched to Trystar LLC: OZPCS-RS40-Bxx {208V} (17,516 W AC), led by EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-iv-16000-hyb-aw-fx-xx-208v/) EG4 Electronics LLC | 13,899 W | -3617 W | 208.0 V | 440.0 V | 96.46% |
| [**Chint Power Systems America: CPS ECH12KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-208v/) Chint Power Systems America | 12,000 W | -5516 W | 208.0 V | 480.0 V | 96.63% |
| [**EcoFlow Inc: EF-PCS-24 {208V 115kW}**](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-115kw/) EcoFlow Inc | 11,444 W | -6072 W | 208.0 V | 480.0 V | 96.52% |
| [**Chint Power Systems America: CPS ECH114KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech114ktl-us-208v/) Chint Power Systems America | 11,350 W | -6166 W | 208.0 V | 480.0 V | 96.63% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS40-Bxx {208V}?

Check Trystar LLC: OZPCS-RS40-Bxx {208V} (17,516 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Trystar LLC: OZPCS-RS40-Bxx {208V}.

### Trystar LLC: OZPCS-RS40-Bxx {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (48.6 A continuous).

### Alternative Inverter Comparison

Compare efficiency (94.15%) and MPPT window (550-820 V) directly against EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Trystar LLC: OZPCS-RS40-Bxx {208V} by Trystar LLC covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

### What breaker and wire size does Trystar LLC: OZPCS-RS40-Bxx {208V} require?

At 17,516 W continuous AC (208 V, 3-phase), continuous current is 48.6 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS40-Bxx {208V} require?

At 17,516 W AC and 208 V, 3-phase, continuous line current is 48.6 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Trystar LLC: OZPCS-RS40-Bxx {208V} compare to EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}?

Trystar LLC: OZPCS-RS40-Bxx {208V} delivers 17,516 W AC at 94.15% CEC efficiency with a 820 V DC ceiling, while EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} outputs 13,899 W at 208 V, 3-phase.

## Related Pages

Explore Trystar LLC hardware, EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}, utility rates, and NEC 705.12 sizing calculators alongside Trystar LLC: OZPCS-RS40-Bxx {208V}.

[All Trystar LLC Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/trystar-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trystar LLC

- [All Trystar LLC Specs](https://epri-peac.com/solar-equipment/brands/trystar-llc/)
- [Trystar LLC: OZPCS-RS40-Bxx {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-bxx-480v/)
- [Trystar LLC: OZPCS-RS40-Fxx {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-fxx-480v/)
- [Trystar LLC: OZPCS-EP40-000 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-ep40-000-480v/)
- [Trystar LLC: OZPCS-RS40-BB1 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-bb1-480v/)
- [Trystar LLC: OZPCS-RS40-FB1 {480V}](https://epri-peac.com/solar-equipment/inverters/trystar-llc/trystar-llc-ozpcs-rs40-fb1-480v/)