title: "Tesla Inc: 1707000-XX-Y {240V Inverter (11,508W)"
url: https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1707000-xx-y-240v-115kw/
description: "CEC specs for Tesla Inc: 1707000-XX-Y {240V 115kW}: 11,508W AC, 240V, 60A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Tesla Inc: 1707000-XX-Y {240V 115kW} — CEC Inverter Specifications

Manufacturer: [**Tesla Inc**](https://epri-peac.com/solar-equipment/brands/tesla-inc/) Registry: **CEC Verified Engineering Specification**

Tesla Inc: 1707000-XX-Y {240V 115kW} outputs 11,508 W AC at 240 V (48.0 A continuous, 60 A OCPD), ranking #782 of 2,343 CEC inverters at 97.19% efficiency with a 270-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 11,508 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 60 A (6 AWG Cu)

- **CEC Efficiency** : 97.19%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Tesla Inc: 1707000-XX-Y {240V 115kW} Compare Against Peer CEC Listings?

Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for Tesla Inc: 1707000-XX-Y {240V 115kW}.

Classified as a hybrid battery-capable inverter (active in CEC directory), Tesla Inc: 1707000-XX-Y {240V 115kW} requires 60.0 A design capacity -> 60 A breaker using 6 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.19% (+0.37 pts vs overall CEC median) across 2,343 CEC models, while its 60 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.

## Where Does Tesla Inc: 1707000-XX-Y {240V 115kW} Fall Across Listed CEC Models?

Output power comparison showing where Tesla Inc: 1707000-XX-Y {240V 115kW} sits among all 2,343 CEC-listed grid-support inverters. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Dataset Percentiles Define Tesla Inc: 1707000-XX-Y {240V 115kW}?

Relative ranking of Tesla Inc: 1707000-XX-Y {240V 115kW} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Tesla Inc: 1707000-XX-Y {240V 115kW}?

Snapshot of Tesla Inc: 1707000-XX-Y {240V 115kW} efficiency rank (#782), OCPD breaker size, MPPT span, and busbar verdict.

Eff #782 / 2,343

### 97.19% CEC Weighted Efficiency

+0.51 pts vs the 96.68% 240 V median; overall power rank #766 (11,508 W, top 32.7%; higher than 67.3% of peers).

NEC 705.12 Check

### 60 A Required Backfeed OCPD

125% x 48.0 A = 60.0 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

### 270 V - 480 V (Max 480 V DC)

Tracking span of 210.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11508.0W / 240 V -> 48.0 A | Breaker >= 1.25 * 48.0 = 60.0 A -> 60 A

CEC Inverters.csv for Tesla Inc: 1707000-XX-Y {240V 115kW}: Paco=11508.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.19%.

**Result:** Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Tesla Inc: 1707000-XX-Y {240V 115kW}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Tesla Inc: 1707000-XX-Y {240V 115kW}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc: 1707000-XX-Y {240V 115kW}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 11,508 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 270 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 31.576 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.19% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Tesla Inc: 1707000-XX-Y {240V 115kW}?

NEC 705.12(B)(3)(2) backfeed compliance table for Tesla Inc: 1707000-XX-Y {240V 115kW} at 240 V. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Evaluates Tesla Inc: 1707000-XX-Y {240V 115kW} (60 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 60 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 60 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 60 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Tesla Inc: 1707000-XX-Y {240V 115kW}?

Minimum and maximum series solar module strings fitting Tesla Inc: 1707000-XX-Y {240V 115kW} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 270.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 8 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 10 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Tesla Inc: 1707000-XX-Y {240V 115kW}?

Peer 240 V CEC inverters near 11,508 W AC output such as Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-hm-240v/) Dyness Digital Energy Technology Co LTD | 11,498 W | -10 W | 240.0 V | 500.0 V | 96.41% |
| [**Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-am-240v/) Dyness Digital Energy Technology Co LTD | 11,519 W | +11 W | 240.0 V | 490.0 V | 96.21% |
| [**Base Power Inc: MIN 11400TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/) Base Power Inc | 11,520 W | +12 W | 240.0 V | 480.0 V | 97.76% |
| [**Delta Electronics: S12_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-s12-bdi-240v/) Delta Electronics | 11,589 W | +81 W | 240.0 V | 480.0 V | 96.99% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Tesla Inc: 1707000-XX-Y {240V 115kW}?

Check Tesla Inc: 1707000-XX-Y {240V 115kW} (11,508 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Tesla Inc: 1707000-XX-Y {240V 115kW}.

### Tesla Inc: 1707000-XX-Y {240V 115kW} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (48.0 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.19%) and MPPT window (270-480 V) directly against Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} (11,498 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Tesla Inc: 1707000-XX-Y {240V 115kW} by Tesla Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Tesla Inc: 1707000-XX-Y {240V 115kW} require?

At 11,508 W continuous AC (240 V), continuous current is 48.0 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

### Does Tesla Inc: 1707000-XX-Y {240V 115kW} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

### How does Tesla Inc: 1707000-XX-Y {240V 115kW} compare to Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}?

Tesla Inc: 1707000-XX-Y {240V 115kW} delivers 11,508 W AC at 97.19% CEC efficiency with a 480 V DC ceiling, while Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} outputs 11,498 W at 240 V.

## Related Pages

Explore Tesla Inc hardware, Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}, utility rates, and NEC 705.12 sizing calculators alongside Tesla Inc: 1707000-XX-Y {240V 115kW}.

[All Tesla Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Tesla Inc

- [All Tesla Inc Specs](https://epri-peac.com/solar-equipment/brands/tesla-inc/)
- [Tesla Inc: 1707000-XX-Y {240V 10kW}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1707000-xx-y-240v-10kw/)
- [Tesla Inc: 1538000-xx-y {240V}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1538000-xx-y-240v/)
- [Tesla Inc: 1538000-xx-y {208V}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1538000-xx-y-208v/)
- [Tesla Inc: 1534000-xx-y {240V}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1534000-xx-y-240v/)
- [Tesla Inc: 1534000-xx-y {208V}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1534000-xx-y-208v/)