Tesla Inc: 1534000-xx-y {240V} outputs 3,800 W AC at 240 V (15.8 A continuous, 20 A OCPD), ranking #506 of 2,343 CEC inverters at 97.61% efficiency with a 270-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,800 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 20 A (12 AWG Cu)

- **CEC Efficiency** : 97.61%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Tesla Inc: 1534000-xx-y {240V} Compare Against Peer CEC Listings?

Breaker sizing (20 A), 12 AWG Cu wire rules, and DC input limits for Tesla Inc: 1534000-xx-y {240V}.

Classified as a grid-tied PV inverter (listed since 2023-01-03), Tesla Inc: 1534000-xx-y {240V} requires 19.8 A design capacity -> 20 A breaker using 12 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.61% (+0.79 pts vs overall CEC median) across 2,343 CEC models, while requires a 20 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).

## Where Does Tesla Inc: 1534000-xx-y {240V} Fall Across Listed CEC Models?

Output power comparison showing where Tesla Inc: 1534000-xx-y {240V} sits among all 2,343 CEC-listed grid-support inverters. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define Tesla Inc: 1534000-xx-y {240V}?

Relative ranking of Tesla Inc: 1534000-xx-y {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Tesla Inc: 1534000-xx-y {240V}?

Snapshot of Tesla Inc: 1534000-xx-y {240V} efficiency rank (#506), OCPD breaker size, MPPT span, and busbar verdict. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Eff #506 / 2,343

### 97.61% CEC Weighted Efficiency

+0.93 pts vs the 96.68% 240 V median; overall power rank #1,650 (3,800 W, below CEC median; higher than 28.7% of peers).

NEC 705.12 Check

### 20 A Required Backfeed OCPD

125% x 15.8 A = 19.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

### 270 V - 425 V (Max 425 V DC)

Tracking span of 155.0 V; listed since 2023-01-03 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3800.0W / 240 V -> 15.8 A | Breaker >= 1.25 * 15.8 = 19.8 A -> 20 A

CEC Inverters.csv for Tesla Inc: 1534000-xx-y {240V}: Paco=3800.0 W, Vac=240 V, Vdcmax=425.0 V, Eff=97.61%.

**Result:** Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Tesla Inc: 1534000-xx-y {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Tesla Inc: 1534000-xx-y {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc: 1534000-xx-y {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,800 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 425 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 270 V - 425 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 11.1234 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.61% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2023-01-03 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Tesla Inc: 1534000-xx-y {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Tesla Inc: 1534000-xx-y {240V} at 240 V. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Tesla Inc: 1534000-xx-y {240V} (20 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 20 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 20 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 20 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 20 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 20 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Tesla Inc: 1534000-xx-y {240V}?

Minimum and maximum series solar module strings fitting Tesla Inc: 1534000-xx-y {240V} MPPT and 425 V limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 270.0-425.0 V MPPT and 425.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 7 panels (fixed) | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 9 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 8 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 10 panels (fixed) | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to Tesla Inc: 1534000-xx-y {240V}?

Peer 240 V CEC inverters near 3,800 W AC output such as ABB: PVI-38-OUTD-S-US-A {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: PVI-38-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-a-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-a-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-m-a-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.2% |
| [**ABB: UNO-DM-38-TL-PLUS-US-SB-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-38-tl-plus-us-sb-ra-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.39% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Tesla Inc: 1534000-xx-y {240V}?

Check Tesla Inc: 1534000-xx-y {240V} (3,800 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Tesla Inc: 1534000-xx-y {240V}.

### Tesla Inc: 1534000-xx-y {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.61%) and MPPT window (270-425 V) directly against ABB: PVI-38-OUTD-S-US-A {240V} (3,800 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Tesla Inc: 1534000-xx-y {240V} by Tesla Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Tesla Inc: 1534000-xx-y {240V} require?

At 3,800 W continuous AC (240 V), continuous current is 15.8 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

### Does Tesla Inc: 1534000-xx-y {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

### How does Tesla Inc: 1534000-xx-y {240V} compare to ABB: PVI-38-OUTD-S-US-A {240V}?

Tesla Inc: 1534000-xx-y {240V} delivers 3,800 W AC at 97.61% CEC efficiency with a 425 V DC ceiling, while ABB: PVI-38-OUTD-S-US-A {240V} outputs 3,800 W at 240 V.

## Related Pages

Explore Tesla Inc hardware, ABB: PVI-38-OUTD-S-US-A {240V}, utility rates, and NEC 705.12 sizing calculators alongside Tesla Inc: 1534000-xx-y {240V}.

[All Tesla Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Tesla Inc

- [All Tesla Inc Specs](https://epri-peac.com/solar-equipment/brands/tesla-inc/)
- [Tesla Inc: 1707000-XX-Y {240V 115kW}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1707000-xx-y-240v-115kw/)
- [Tesla Inc: 1707000-XX-Y {240V 10kW}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1707000-xx-y-240v-10kw/)
- [Tesla Inc: 1538000-xx-y {240V}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1538000-xx-y-240v/)
- [Tesla Inc: 1538000-xx-y {208V}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1538000-xx-y-208v/)
- [Tesla Inc: 1534000-xx-y {208V}](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1534000-xx-y-208v/)