title: "Sungrow Power Supply Co Ltd Inverter (3,434,560W)"
url: https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3425ud-600v/
description: "CEC specs for Sungrow Power Supply Co Ltd: SG3425UD {600V}: 3,434,560W AC, 600V, 4150A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Sungrow Power Supply Co Ltd: SG3425UD {600V} — CEC Inverter Specifications

Manufacturer: [**Sungrow Power Supply Co Ltd**](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/) Registry: **CEC Verified Engineering Specification**

Sungrow Power Supply Co Ltd: SG3425UD {600V} outputs 3,434,560 W AC at 600 V, 3-phase (3305.0 A continuous, 4,150 A OCPD), ranking #711 of 2,343 CEC inverters at 97.26% efficiency with a 875-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,434,560 W

- **AC Voltage** : 600 V, 3-phase

- **Min PV Breaker** : 4,150 A (parallel Cu feeders)

- **CEC Efficiency** : 97.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sungrow Power Supply Co Ltd: SG3425UD {600V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for Sungrow Power Supply Co Ltd: SG3425UD {600V}.

Ranking #27 of 2,343 CEC inverters (top 1.2%; higher than 98.8% of peers), Sungrow Power Supply Co Ltd: SG3425UD {600V} is a grid-tied PV inverter delivering 3,434,560 W continuous AC at 600 V, 3-phase (3305.0 A continuous). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.26% (-1.02 pts vs the 98.28% 600 V median) against peers like Gamesa Electric: PV3800 {600V} (3,418,394 W).

## Where Does Sungrow Power Supply Co Ltd: SG3425UD {600V} Fall Across Listed CEC Models?

Marks Sungrow Power Supply Co Ltd: SG3425UD {600V} (3,434,560 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define Sungrow Power Supply Co Ltd: SG3425UD {600V}?

Benchmarks Sungrow Power Supply Co Ltd: SG3425UD {600V} continuous AC output, 97.26% CEC weighted efficiency, and 4,150 A OCPD breaker demand.

## What Do the Dataset Ranks Show for Sungrow Power Supply Co Ltd: SG3425UD {600V}?

Four key NEC 705.12 and California Energy Commission metrics defining Sungrow Power Supply Co Ltd: SG3425UD {600V} by Sungrow Power Supply Co Ltd.

Eff #711 / 2,343

### 97.26% CEC Weighted Efficiency

-1.02 pts vs the 98.28% 600 V median; overall power rank #27 (3,434,560 W, top 1.2%; higher than 98.8% of peers).

NEC 705.12 Check

### 4,150 A Required Backfeed OCPD

125% x 3305.0 A = 4131.2 A -> 4,150 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 875 V - 1,300 V (Max 1,300 V DC)

Tracking span of 425.0 V; listed since 2023-03-21 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3434560.0W / 600 V 3-phase -> 3305.0 A | Breaker >= 1.25 * 3305.0 = 4131.2 A -> 4,150 A

CEC Inverters.csv for Sungrow Power Supply Co Ltd: SG3425UD {600V}: Paco=3434560.0 W, Vac=600 V, Vdcmax=1300.0 V, Eff=97.26%.

**Result:** Min 4,150 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for Sungrow Power Supply Co Ltd: SG3425UD {600V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Sungrow Power Supply Co Ltd: SG3425UD {600V}.

Official California Energy Commission (NREL SAM) test parameters for Sungrow Power Supply Co Ltd: SG3425UD {600V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,434,560 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 600 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,300 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 875 V - 1,300 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 3210.34 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.26% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2023-03-21 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Sungrow Power Supply Co Ltd: SG3425UD {600V} (600 V, 3-phase)?

Evaluates Sungrow Power Supply Co Ltd: SG3425UD {600V} (4,150 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Sungrow Power Supply Co Ltd: SG3425UD {600V} (4150 A required OCPD at 600 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (600V)** | 40 A | 4,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (600V)** | 80 A | 4,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (600V)** | 120 A | 4,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (600V)** | 160 A | 4,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (600V)** | 240 A | 4,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With Sungrow Power Supply Co Ltd: SG3425UD {600V}?

Sample PV string lengths aligned within 875-1,300 V MPPT and 1,300 V DC max at -10 C. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sampled CEC PV modules aligned within 875.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 21 to 23 panels | 13.57 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 27 to 30 panels | 13.2 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 26 to 29 panels | 12.32 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 31 to 32 panels | 6.4 kW |

## Which Competing Grid-Support Inverters Compare to Sungrow Power Supply Co Ltd: SG3425UD {600V}?

Competing CEC grid-support inverters near 3,434,560 W AC and 600 V, 3-phase, led by Gamesa Electric: PV3800 {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Gamesa Electric: PV3800 {600V}**](https://epri-peac.com/solar-equipment/inverters/gamesa-electric/gamesa-electric-pv3800-600v/) Gamesa Electric | 3,418,394 W | -16166 W | 600.0 V | 1300.0 V | 97.53% |
| [**SMA America: SC 4000 UP-US 600V 3850A {600V}**](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/) SMA America | 3,650,134 W | +215574 W | 600.0 V | 1200.0 V | 98.07% |
| [**Power Electronics: FS3000K {600V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs3000k-600v/) Power Electronics | 3,121,310 W | -313250 W | 600.0 V | 1200.0 V | 97.89% |
| [**Power Electronics: FP3000K3 {600V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fp3000k3-600v/) Power Electronics | 3,116,969 W | -317591 W | 600.0 V | 1200.0 V | 97.99% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Sungrow Power Supply Co Ltd: SG3425UD {600V}?

Check Sungrow Power Supply Co Ltd: SG3425UD {600V} (3,434,560 W AC, 4,150 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on Sungrow Power Supply Co Ltd: SG3425UD {600V}.

### Sungrow Power Supply Co Ltd: SG3425UD {600V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 4,150 A OCPD breaker (3305.0 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.26%) and MPPT window (875-1,300 V) directly against Gamesa Electric: PV3800 {600V} (3,418,394 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow Power Supply Co Ltd: SG3425UD {600V} by Sungrow Power Supply Co Ltd covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

### What breaker and wire size does Sungrow Power Supply Co Ltd: SG3425UD {600V} require?

At 3,434,560 W continuous AC (600 V, 3-phase), continuous current is 3305.0 A; 125% NEC 690.8/705.12 sizing requires a 4,150 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does Sungrow Power Supply Co Ltd: SG3425UD {600V} require?

At 3,434,560 W AC and 600 V, 3-phase, continuous line current is 3305.0 A, requiring a 4,150 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

### How does Sungrow Power Supply Co Ltd: SG3425UD {600V} compare to Gamesa Electric: PV3800 {600V}?

Sungrow Power Supply Co Ltd: SG3425UD {600V} delivers 3,434,560 W AC at 97.26% CEC efficiency with a 1,300 V DC ceiling, while Gamesa Electric: PV3800 {600V} outputs 3,418,394 W at 600 V, 3-phase.

## Related Pages

Explore Sungrow Power Supply Co Ltd hardware, Gamesa Electric: PV3800 {600V}, utility rates, and NEC 705.12 sizing calculators alongside Sungrow Power Supply Co Ltd: SG3425UD {600V}.

[All Sungrow Power Supply Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sungrow Power Supply Co Ltd

- [All Sungrow Power Supply Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/)
- [Sungrow Power Supply Co Ltd: SG3600UD {630V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3600ud-630v/)
- [Sungrow Power Supply Co Ltd: SG3150U {630V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3150u-630v/)
- [Sungrow Power Supply Co Ltd: SC2500UD-US {900V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sc2500ud-us-900v/)
- [Sungrow Power Supply Co Ltd: SC2500U {550V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sc2500u-550v/)
- [Sungrow Power Supply Co Ltd: SG2500U {550V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg2500u-550v/)