title: "Sungrow Power Supply Co Ltd Inverter (226,997W)"
url: https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg250hx-us-800v/
description: "CEC specs for Sungrow Power Supply Co Ltd: SG250HX-US {800V}: 226,997W AC, 800V, 225A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Sungrow Power Supply Co Ltd: SG250HX-US {800V} — CEC Inverter Specifications

Manufacturer: [**Sungrow Power Supply Co Ltd**](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/) Registry: **CEC Verified Engineering Specification**

Sungrow Power Supply Co Ltd: SG250HX-US {800V} outputs 226,997 W AC at 800 V, 3-phase (163.8 A continuous, 225 A OCPD), ranking #67 of 2,343 CEC inverters at 98.52% efficiency with a 860-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 226,997 W

- **AC Voltage** : 800 V, 3-phase

- **Min PV Breaker** : 225 A (4/0 AWG Cu)

- **CEC Efficiency** : 98.52%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sungrow Power Supply Co Ltd: SG250HX-US {800V} Compare Against Peer CEC Listings?

CEC efficiency rank (#67), 860-1,300 V MPPT tracking, and panel fit for Sungrow Power Supply Co Ltd: SG250HX-US {800V}.

Sungrow Power Supply Co Ltd: SG250HX-US {800V} from Sungrow Power Supply Co Ltd outputs 163.8 A continuous AC at 800 V, 3-phase (226,997 W AC, rank #237). Paired with 4/0 AWG Cu conductors and a 225 A OCPD, its 98.52% CEC efficiency compares closely with Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V} (238,706 W). Keep NEC 690.7 winter string Voc below 1,300 V DC.

## Where Does Sungrow Power Supply Co Ltd: SG250HX-US {800V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Sungrow Power Supply Co Ltd: SG250HX-US {800V} at 226,997 W continuous AC output.

## What Dataset Percentiles Define Sungrow Power Supply Co Ltd: SG250HX-US {800V}?

Dataset percentiles comparing Sungrow Power Supply Co Ltd: SG250HX-US {800V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for Sungrow Power Supply Co Ltd: SG250HX-US {800V}?

Engineering highlights for Sungrow Power Supply Co Ltd: SG250HX-US {800V} covering efficiency, 4/0 AWG Cu feeder, and panel compatibility.

Eff #67 / 2,343

### 98.52% CEC Weighted Efficiency

+0.22 pts vs the 98.3% 800 V median; overall power rank #237 (226,997 W, top 10.1%; higher than 89.9% of peers).

NEC 705.12 Check

### 225 A Required Backfeed OCPD

125% x 163.8 A = 204.8 A -> 225 A standard OCPD using 4/0 AWG Cu (75 C).

MPPT Window

### 860 V - 1,300 V (Max 1,300 V DC)

Tracking span of 440.0 V; listed since 2021-02-22 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 226997.0W / 800 V 3-phase -> 163.8 A | Breaker >= 1.25 * 163.8 = 204.8 A -> 225 A

CEC Inverters.csv for Sungrow Power Supply Co Ltd: SG250HX-US {800V}: Paco=226997.0 W, Vac=800 V, Vdcmax=1300.0 V, Eff=98.52%.

**Result:** Min 225 A breaker & 4/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (800V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Sungrow Power Supply Co Ltd: SG250HX-US {800V}?

California Energy Commission Solar Equipment List parameters for Sungrow Power Supply Co Ltd: SG250HX-US {800V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Sungrow Power Supply Co Ltd: SG250HX-US {800V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 226,997 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 800 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,300 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 860 V - 1,300 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 213.33 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.52% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2021-02-22 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Sungrow Power Supply Co Ltd: SG250HX-US {800V} (800 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Sungrow Power Supply Co Ltd: SG250HX-US {800V} (225 A OCPD). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Evaluates Sungrow Power Supply Co Ltd: SG250HX-US {800V} (225 A required OCPD at 800 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (800V)** | 40 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (800V)** | 80 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (800V)** | 120 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (800V)** | 160 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (800V)** | 240 A | 225 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Sungrow Power Supply Co Ltd: SG250HX-US {800V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Sungrow Power Supply Co Ltd: SG250HX-US {800V}.

Sampled CEC PV modules aligned within 860.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 21 to 23 panels | 13.57 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 26 to 30 panels | 13.2 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 25 to 29 panels | 12.32 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 30 to 32 panels | 6.4 kW |

## Which Competing Grid-Support Inverters Compare to Sungrow Power Supply Co Ltd: SG250HX-US {800V}?

Four alternative CEC inverters matched to Sungrow Power Supply Co Ltd: SG250HX-US {800V} (226,997 W AC), led by Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}**](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-plus-800v/) Ginlong Technologies Co Ltd | 238,706 W | +11709 W | 800.0 V | 1300.0 V | 98.26% |
| [**Chint Power Systems America: CPS ECB200KTL/US-800 {800V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ecb200ktl-us-800-800v/) Chint Power Systems America | 200,000 W | -26997 W | 800.0 V | 1500.0 V | 97.55% |
| [**CSI Solar Co Ltd: CSI-255K-T800GL02-U {800V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-255k-t800gl02-u-800v/) CSI Solar Co Ltd | 255,013 W | +28016 W | 800.0 V | 1300.0 V | 98.34% |
| [**CSI Solar Co Ltd: CSI-255K-T800GL03-U {800V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-255k-t800gl03-u-800v/) CSI Solar Co Ltd | 255,013 W | +28016 W | 800.0 V | 1300.0 V | 98.34% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Sungrow Power Supply Co Ltd: SG250HX-US {800V}?

Check Sungrow Power Supply Co Ltd: SG250HX-US {800V} (226,997 W AC, 225 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on Sungrow Power Supply Co Ltd: SG250HX-US {800V}.

### Sungrow Power Supply Co Ltd: SG250HX-US {800V} Panel & Wire Spec

Size 75 C copper conductors at 4/0 AWG Cu on a 225 A OCPD breaker (163.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.52%) and MPPT window (860-1,300 V) directly against Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V} (238,706 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow Power Supply Co Ltd: SG250HX-US {800V} by Sungrow Power Supply Co Ltd covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.

### What breaker and wire size does Sungrow Power Supply Co Ltd: SG250HX-US {800V} require?

At 226,997 W continuous AC (800 V, 3-phase), continuous current is 163.8 A; 125% NEC 690.8/705.12 sizing requires a 225 A breaker and 4/0 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Sungrow Power Supply Co Ltd: SG250HX-US {800V} require?

At 226,997 W AC and 800 V, 3-phase, continuous line current is 163.8 A, requiring a 225 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.

### How does Sungrow Power Supply Co Ltd: SG250HX-US {800V} compare to Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}?

Sungrow Power Supply Co Ltd: SG250HX-US {800V} delivers 226,997 W AC at 98.52% CEC efficiency with a 1,300 V DC ceiling, while Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V} outputs 238,706 W at 800 V, 3-phase.

## Related Pages

Explore Sungrow Power Supply Co Ltd hardware, Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}, utility rates, and NEC 705.12 sizing calculators alongside Sungrow Power Supply Co Ltd: SG250HX-US {800V}.

[All Sungrow Power Supply Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sungrow Power Supply Co Ltd

- [All Sungrow Power Supply Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/)
- [Sungrow Power Supply Co Ltd: SG3600UD {630V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3600ud-630v/)
- [Sungrow Power Supply Co Ltd: SG3425UD {600V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3425ud-600v/)
- [Sungrow Power Supply Co Ltd: SG3150U {630V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3150u-630v/)
- [Sungrow Power Supply Co Ltd: SC2500UD-US {900V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sc2500ud-us-900v/)
- [Sungrow Power Supply Co Ltd: SC2500U {550V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sc2500u-550v/)