title: "Sungrow Power Supply Co Ltd Inverter (212,078W)"
url: https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sc210hx-us-690v/
description: "CEC specs for Sungrow Power Supply Co Ltd: SC210HX-US {690V}: 212,078W AC, 690V, 225A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Sungrow Power Supply Co Ltd: SC210HX-US {690V} — CEC Inverter Specifications

Manufacturer: [**Sungrow Power Supply Co Ltd**](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/) Registry: **CEC Verified Engineering Specification**

Sungrow Power Supply Co Ltd: SC210HX-US {690V} outputs 212,078 W AC at 690 V, 3-phase (177.5 A continuous, 225 A OCPD), ranking #79 of 2,343 CEC inverters at 98.49% efficiency with a 1,000-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 212,078 W

- **AC Voltage** : 690 V, 3-phase

- **Min PV Breaker** : 225 A (4/0 AWG Cu)

- **CEC Efficiency** : 98.49%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sungrow Power Supply Co Ltd: SC210HX-US {690V} Compare Against Peer CEC Listings?

Breaker sizing (225 A), 4/0 AWG Cu wire rules, and DC input limits for Sungrow Power Supply Co Ltd: SC210HX-US {690V}.

Classified as a grid-tied PV inverter (active in CEC directory), Sungrow Power Supply Co Ltd: SC210HX-US {690V} requires 221.9 A design capacity -> 225 A breaker using 4/0 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 98.49% (+1.67 pts vs overall CEC median) across 2,343 CEC models, while commercial 690 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (690v) or nec 705.11 supply-side tap.

## Where Does Sungrow Power Supply Co Ltd: SC210HX-US {690V} Fall Across Listed CEC Models?

Output power comparison showing where Sungrow Power Supply Co Ltd: SC210HX-US {690V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Sungrow Power Supply Co Ltd: SC210HX-US {690V}?

Relative ranking of Sungrow Power Supply Co Ltd: SC210HX-US {690V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Sungrow Power Supply Co Ltd: SC210HX-US {690V}?

Snapshot of Sungrow Power Supply Co Ltd: SC210HX-US {690V} efficiency rank (#79), OCPD breaker size, MPPT span, and busbar verdict.

Eff #79 / 2,343

### 98.49% CEC Weighted Efficiency

+0.32 pts vs the 98.17% 690 V median; overall power rank #244 (212,078 W, top 10.4%; higher than 89.6% of peers).

NEC 705.12 Check

### 225 A Required Backfeed OCPD

125% x 177.5 A = 221.9 A -> 225 A standard OCPD using 4/0 AWG Cu (75 C).

MPPT Window

### 1,000 V - 1,500 V (Max 1,500 V DC)

Tracking span of 500.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 212078.0W / 690 V 3-phase -> 177.5 A | Breaker >= 1.25 * 177.5 = 221.9 A -> 225 A

CEC Inverters.csv for Sungrow Power Supply Co Ltd: SC210HX-US {690V}: Paco=212078.0 W, Vac=690 V, Vdcmax=1500.0 V, Eff=98.49%.

**Result:** Min 225 A breaker & 4/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (690V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Sungrow Power Supply Co Ltd: SC210HX-US {690V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Sungrow Power Supply Co Ltd: SC210HX-US {690V}.

Official California Energy Commission (NREL SAM) test parameters for Sungrow Power Supply Co Ltd: SC210HX-US {690V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 212,078 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 690 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 1,000 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 172.263 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.49% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Sungrow Power Supply Co Ltd: SC210HX-US {690V} (690 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Sungrow Power Supply Co Ltd: SC210HX-US {690V} at 690 V, 3-phase.

Evaluates Sungrow Power Supply Co Ltd: SC210HX-US {690V} (225 A required OCPD at 690 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (690V)** | 40 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (690V)** | 80 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (690V)** | 120 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (690V)** | 160 A | 225 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (690V)** | 240 A | 225 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Sungrow Power Supply Co Ltd: SC210HX-US {690V}?

Minimum and maximum series solar module strings fitting Sungrow Power Supply Co Ltd: SC210HX-US {690V} MPPT and 1,500 V limits.

Sampled CEC PV modules aligned within 1000.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 24 to 26 panels | 15.34 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 30 to 35 panels | 15.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 30 to 33 panels | 14.03 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 35 to 36 panels | 7.2 kW |

## Which Competing Grid-Support Inverters Compare to Sungrow Power Supply Co Ltd: SC210HX-US {690V}?

Peer 690 V, 3-phase CEC inverters near 212,078 W AC output such as CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csec-215k-t6901a-u-690v/) CSI Solar Co Ltd | 215,937 W | +3859 W | 690.0 V | 1500.0 V | 98.38% |
| [**Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}**](https://epri-peac.com/solar-equipment/inverters/shenzhen-cubenergy-co-ltd/shenzhen-cubenergy-co-ltd-eh-0200-ha-m-us-690v/) Shenzhen Cubenergy Co Ltd | 220,432 W | +8354 W | 690.0 V | 1346.0 V | 97.54% |
| [**SINENG ELECTRIC CO LTD: EH-0200-HA-M-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-0200-ha-m-us-690v/) SINENG ELECTRIC CO LTD | 220,432 W | +8354 W | 690.0 V | 1346.0 V | 97.54% |
| [**CSI Solar Co Ltd: CSEC-200K-T6901A-U {690V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csec-200k-t6901a-u-690v/) CSI Solar Co Ltd | 200,706 W | -11372 W | 690.0 V | 1500.0 V | 98.42% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Sungrow Power Supply Co Ltd: SC210HX-US {690V}?

Check Sungrow Power Supply Co Ltd: SC210HX-US {690V} (212,078 W AC, 225 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on Sungrow Power Supply Co Ltd: SC210HX-US {690V}.

### Sungrow Power Supply Co Ltd: SC210HX-US {690V} Panel & Wire Spec

Size 75 C copper conductors at 4/0 AWG Cu on a 225 A OCPD breaker (177.5 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.49%) and MPPT window (1,000-1,500 V) directly against CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V} (215,937 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow Power Supply Co Ltd: SC210HX-US {690V} by Sungrow Power Supply Co Ltd covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

### What breaker and wire size does Sungrow Power Supply Co Ltd: SC210HX-US {690V} require?

At 212,078 W continuous AC (690 V, 3-phase), continuous current is 177.5 A; 125% NEC 690.8/705.12 sizing requires a 225 A breaker and 4/0 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Sungrow Power Supply Co Ltd: SC210HX-US {690V} require?

At 212,078 W AC and 690 V, 3-phase, continuous line current is 177.5 A, requiring a 225 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

### How does Sungrow Power Supply Co Ltd: SC210HX-US {690V} compare to CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V}?

Sungrow Power Supply Co Ltd: SC210HX-US {690V} delivers 212,078 W AC at 98.49% CEC efficiency with a 1,500 V DC ceiling, while CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V} outputs 215,937 W at 690 V, 3-phase.

## Related Pages

Explore Sungrow Power Supply Co Ltd hardware, CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V}, utility rates, and NEC 705.12 sizing calculators alongside Sungrow Power Supply Co Ltd: SC210HX-US {690V}.

[All Sungrow Power Supply Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sungrow Power Supply Co Ltd

- [All Sungrow Power Supply Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/sungrow-power-supply-co-ltd/)
- [Sungrow Power Supply Co Ltd: SG3600UD {630V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3600ud-630v/)
- [Sungrow Power Supply Co Ltd: SG3425UD {600V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3425ud-600v/)
- [Sungrow Power Supply Co Ltd: SG3150U {630V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3150u-630v/)
- [Sungrow Power Supply Co Ltd: SC2500UD-US {900V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sc2500ud-us-900v/)
- [Sungrow Power Supply Co Ltd: SC2500U {550V}](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sc2500u-550v/)