title: "Star Charge Americas Corp Inverter (3,315W)"
url: https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si403lula00-208v/
description: "CEC specs for Star Charge Americas Corp: SI403LULA00 {208V}: 3,315W AC, 208V, 20A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Star Charge Americas Corp: SI403LULA00 {208V} — CEC Inverter Specifications

Manufacturer: [**Star Charge Americas Corp**](https://epri-peac.com/solar-equipment/brands/star-charge-americas-corp/) Registry: **CEC Verified Engineering Specification**

Star Charge Americas Corp: SI403LULA00 {208V} outputs 3,315 W AC at 208 V, commercial single-phase (15.9 A continuous, 20 A OCPD), ranking #564 of 2,343 CEC inverters at 97.45% efficiency with a 180-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,315 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 20 A (12 AWG Cu)

- **CEC Efficiency** : 97.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Star Charge Americas Corp: SI403LULA00 {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#564), 180-480 V MPPT tracking, and panel fit for Star Charge Americas Corp: SI403LULA00 {208V}.

Star Charge Americas Corp: SI403LULA00 {208V} from Star Charge Americas Corp outputs 15.9 A continuous AC at 208 V, commercial single-phase (3,315 W AC, rank #1,709). Paired with 12 AWG Cu conductors and a 20 A OCPD, its 97.45% CEC efficiency compares closely with Delta Electronics: SOLIVIA 38 NA G4 TL {208V} (3,320 W). Keep NEC 690.7 winter string Voc below 480 V DC.

## Where Does Star Charge Americas Corp: SI403LULA00 {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Star Charge Americas Corp: SI403LULA00 {208V} at 3,315 W continuous AC output. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define Star Charge Americas Corp: SI403LULA00 {208V}?

Dataset percentiles comparing Star Charge Americas Corp: SI403LULA00 {208V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for Star Charge Americas Corp: SI403LULA00 {208V}?

Engineering highlights for Star Charge Americas Corp: SI403LULA00 {208V} covering efficiency, 12 AWG Cu feeder, and panel compatibility.

Eff #564 / 2,343

### 97.45% CEC Weighted Efficiency

+1.04 pts vs the 96.41% 208 V median; overall power rank #1,709 (3,315 W, below CEC median; higher than 27.1% of peers).

NEC 705.12 Check

### 20 A Required Backfeed OCPD

125% x 15.9 A = 19.9 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

### 180 V - 480 V (Max 480 V DC)

Tracking span of 300.0 V; listed since 2025-05-21 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3315.0W / 208 V -> 15.9 A | Breaker >= 1.25 * 15.9 = 19.9 A -> 20 A

CEC Inverters.csv for Star Charge Americas Corp: SI403LULA00 {208V}: Paco=3315.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=97.45%.

**Result:** Min 20 A breaker & 12 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Star Charge Americas Corp: SI403LULA00 {208V}?

California Energy Commission Solar Equipment List parameters for Star Charge Americas Corp: SI403LULA00 {208V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Star Charge Americas Corp: SI403LULA00 {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,315 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 180 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 9.4489 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.45% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-05-21 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Star Charge Americas Corp: SI403LULA00 {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Star Charge Americas Corp: SI403LULA00 {208V} (20 A OCPD). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Evaluates Star Charge Americas Corp: SI403LULA00 {208V} (20 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 20 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (208V)** | 80 A | 20 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 20 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 20 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 20 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Star Charge Americas Corp: SI403LULA00 {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Star Charge Americas Corp: SI403LULA00 {208V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sampled CEC PV modules aligned within 180.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Star Charge Americas Corp: SI403LULA00 {208V}?

Four alternative CEC inverters matched to Star Charge Americas Corp: SI403LULA00 {208V} (3,315 W AC), led by Delta Electronics: SOLIVIA 38 NA G4 TL {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Delta Electronics: SOLIVIA 38 NA G4 TL {208V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-solivia-38-na-g4-tl-208v/) Delta Electronics | 3,320 W | +5 W | 208.0 V | 500.0 V | 97.23% |
| [**ABB: UNO-DM-38-TL-PLUS-US-SB-RA {208V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-38-tl-plus-us-sb-ra-208v/) ABB | 3,300 W | -15 W | 208.0 V | 480.0 V | 95.88% |
| [**ABB: UNO-DM-38-TL-PLUS-US-SB-RA-Q {208V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-38-tl-plus-us-sb-ra-q-208v/) ABB | 3,300 W | -15 W | 208.0 V | 480.0 V | 95.88% |
| [**ABB: UNO-DM-38-TL-PLUS-US-SE-RA {208V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-38-tl-plus-us-se-ra-208v/) ABB | 3,300 W | -15 W | 208.0 V | 480.0 V | 95.88% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Star Charge Americas Corp: SI403LULA00 {208V}?

Check Star Charge Americas Corp: SI403LULA00 {208V} (3,315 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Star Charge Americas Corp: SI403LULA00 {208V}.

### Star Charge Americas Corp: SI403LULA00 {208V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.45%) and MPPT window (180-480 V) directly against Delta Electronics: SOLIVIA 38 NA G4 TL {208V} (3,320 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Star Charge Americas Corp: SI403LULA00 {208V} by Star Charge Americas Corp covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does Star Charge Americas Corp: SI403LULA00 {208V} require?

At 3,315 W continuous AC (208 V, commercial single-phase), continuous current is 15.9 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Star Charge Americas Corp: SI403LULA00 {208V} require?

At 3,315 W AC and 208 V, commercial single-phase, continuous line current is 15.9 A, requiring a 20 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Star Charge Americas Corp: SI403LULA00 {208V} compare to Delta Electronics: SOLIVIA 38 NA G4 TL {208V}?

Star Charge Americas Corp: SI403LULA00 {208V} delivers 3,315 W AC at 97.45% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: SOLIVIA 38 NA G4 TL {208V} outputs 3,320 W at 208 V, commercial single-phase.

## Related Pages

Explore Star Charge Americas Corp hardware, Delta Electronics: SOLIVIA 38 NA G4 TL {208V}, utility rates, and NEC 705.12 sizing calculators alongside Star Charge Americas Corp: SI403LULA00 {208V}.

[All Star Charge Americas Corp Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/star-charge-americas-corp/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Star Charge Americas Corp

- [All Star Charge Americas Corp Specs](https://epri-peac.com/solar-equipment/brands/star-charge-americas-corp/)
- [Star Charge Americas Corp: SI135TULT10 {480V}](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si135tult10-480v/)
- [Star Charge Americas Corp: SI135TULT00 {480V}](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si135tult00-480v/)
- [Star Charge Americas Corp: SI125TULT00 {480V}](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si125tult00-480v/)
- [Star Charge Americas Corp: SI125TULT10 {480V}](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si125tult10-480v/)
- [Star Charge Americas Corp: SI104LULA00 {240V}](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si104lula00-240v/)