title: "Solvari Inc: SVR-A11-240 {240V} Inverter (398W)"
url: https://epri-peac.com/solar-equipment/inverters/solvari-inc/solvari-inc-svr-a11-240-240v/
description: "CEC specs for Solvari Inc: SVR-A11-240 {240V}: 398W AC, 240V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Solvari Inc: SVR-A11-240 {240V} — CEC Inverter Specifications

Manufacturer: [**Solvari Inc**](https://epri-peac.com/solar-equipment/brands/solvari-inc/) Registry: **CEC Verified Engineering Specification**

Solvari Inc: SVR-A11-240 {240V} outputs 398 W AC at 240 V (1.7 A continuous, 15 A OCPD), ranking #1,785 of 2,343 CEC inverters at 96.28% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 398 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solvari Inc: SVR-A11-240 {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,785), 22-55 V MPPT tracking, and panel fit for Solvari Inc: SVR-A11-240 {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Operating at 240 V, Solvari Inc: SVR-A11-240 {240V} converts DC array energy at 96.28% CEC weighted efficiency (below overall CEC median; higher than 23.3% of peers) with a 55 V max DC input and 11.8109 A max input current for NEC 690.7 string safety. Compare this 398 W grid-tied PV inverter directly with Aptos Solar Technology LLC: MAC-400 {240V} (382 W). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.

## Where Does Solvari Inc: SVR-A11-240 {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Solvari Inc: SVR-A11-240 {240V} at 398 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Dataset Percentiles Define Solvari Inc: SVR-A11-240 {240V}?

Dataset percentiles comparing Solvari Inc: SVR-A11-240 {240V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for Solvari Inc: SVR-A11-240 {240V}?

Engineering highlights for Solvari Inc: SVR-A11-240 {240V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #1,785 / 2,343

### 96.28% CEC Weighted Efficiency

-0.40 pts vs the 96.68% 240 V median; overall power rank #1,986 (398 W, below CEC median; higher than 15.2% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 1.7 A = 2.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 398.0W / 240 V -> 1.7 A | Breaker >= 1.25 * 1.7 = 2.1 A -> 15 A

CEC Inverters.csv for Solvari Inc: SVR-A11-240 {240V}: Paco=398.0 W, Vac=240 V, Vdcmax=55.0 V, Eff=96.28%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Solvari Inc: SVR-A11-240 {240V}?

California Energy Commission Solar Equipment List parameters for Solvari Inc: SVR-A11-240 {240V} (grid-tied PV inverter) interconnection. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Solvari Inc: SVR-A11-240 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 398 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 11.8109 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.28% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Solvari Inc: SVR-A11-240 {240V}?

Panelboard and switchgear backfeed allowances for Solvari Inc: SVR-A11-240 {240V} (15 A OCPD). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Evaluates Solvari Inc: SVR-A11-240 {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Solvari Inc: SVR-A11-240 {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Solvari Inc: SVR-A11-240 {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |

## Which Competing Grid-Support Inverters Compare to Solvari Inc: SVR-A11-240 {240V}?

Four alternative CEC inverters matched to Solvari Inc: SVR-A11-240 {240V} (398 W AC), led by Aptos Solar Technology LLC: MAC-400 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC: MAC-400 {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400-240v/) Aptos Solar Technology LLC | 382 W | -16 W | 240.0 V | 48.0 V | 96.52% |
| [**Aptos Solar Technology LLC: MAC-400R {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400r-240v/) Aptos Solar Technology LLC | 382 W | -16 W | 240.0 V | 48.0 V | 96.52% |
| [**Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}**](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-250e-60-72-208-240-mc4-240v/) Chilicon Power LLC | 289 W | -109 W | 240.0 V | 32.0 V | 95.41% |
| [**Altenergy Power System Inc: YC600 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-yc600-240v/) Altenergy Power System Inc | 550 W | +152 W | 240.0 V | 45.0 V | 96.51% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Solvari Inc: SVR-A11-240 {240V}?

Check Solvari Inc: SVR-A11-240 {240V} (398 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Solvari Inc: SVR-A11-240 {240V}.

### Solvari Inc: SVR-A11-240 {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.28%) and MPPT window (22-55 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Solvari Inc: SVR-A11-240 {240V} by Solvari Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Solvari Inc: SVR-A11-240 {240V} require?

At 398 W continuous AC (240 V), continuous current is 1.7 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Solvari Inc: SVR-A11-240 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Solvari Inc: SVR-A11-240 {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?

Solvari Inc: SVR-A11-240 {240V} delivers 398 W AC at 96.28% CEC efficiency with a 55 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.

## Related Pages

Explore Solvari Inc hardware, Aptos Solar Technology LLC: MAC-400 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Solvari Inc: SVR-A11-240 {240V}.

[All Solvari Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/solvari-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solvari Inc

- [All Solvari Inc Specs](https://epri-peac.com/solar-equipment/brands/solvari-inc/)
- [Solvari Inc: SVR-A10-240 {240V}](https://epri-peac.com/solar-equipment/inverters/solvari-inc/solvari-inc-svr-a10-240-240v/)
- [Solvari Inc: SVR-A11-208 {208V}](https://epri-peac.com/solar-equipment/inverters/solvari-inc/solvari-inc-svr-a11-208-208v/)
- [Solvari Inc: SVR-A10-208 {208V}](https://epri-peac.com/solar-equipment/inverters/solvari-inc/solvari-inc-svr-a10-208-208v/)