title: "SolarJuice American Inc: S4A-A86 Inverter (8,613W)"
url: https://epri-peac.com/solar-equipment/inverters/solarjuice-american-inc/solarjuice-american-inc-s4a-a86-240v/
description: "CEC specs for SolarJuice American Inc: S4A-A86 {240V}: 8,613W AC, 240V, 45A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# SolarJuice American Inc: S4A-A86 {240V} — CEC Inverter Specifications

Manufacturer: [**SolarJuice American Inc**](https://epri-peac.com/solar-equipment/brands/solarjuice-american-inc/) Registry: **CEC Verified Engineering Specification**

SolarJuice American Inc: S4A-A86 {240V} outputs 8,613 W AC at 240 V (35.9 A continuous, 45 A OCPD), ranking #2,215 of 2,343 CEC inverters at 95.32% efficiency with a 363-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 8,613 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 45 A (8 AWG Cu)

- **CEC Efficiency** : 95.32%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SolarJuice American Inc: S4A-A86 {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,215), 363-430 V MPPT tracking, and panel fit for SolarJuice American Inc: S4A-A86 {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

SolarJuice American Inc: S4A-A86 {240V} from SolarJuice American Inc outputs 35.9 A continuous AC at 240 V (8,613 W AC, rank #1,057). Paired with 8 AWG Cu conductors and a 45 A OCPD, its 95.32% CEC efficiency compares closely with ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W). Keep NEC 690.7 winter string Voc below 430 V DC.

## Where Does SolarJuice American Inc: S4A-A86 {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SolarJuice American Inc: S4A-A86 {240V} at 8,613 W continuous AC output. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define SolarJuice American Inc: S4A-A86 {240V}?

Dataset percentiles comparing SolarJuice American Inc: S4A-A86 {240V} against 2,343 certified grid-support inverters nationwide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Do the Dataset Ranks Show for SolarJuice American Inc: S4A-A86 {240V}?

Engineering highlights for SolarJuice American Inc: S4A-A86 {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #2,215 / 2,343

### 95.32% CEC Weighted Efficiency

-1.36 pts vs the 96.68% 240 V median; overall power rank #1,057 (8,613 W, top 45.2%; higher than 54.8% of peers).

NEC 705.12 Check

### 45 A Required Backfeed OCPD

125% x 35.9 A = 44.9 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 363 V - 430 V (Max 430 V DC)

Tracking span of 67.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8613.0W / 240 V -> 35.9 A | Breaker >= 1.25 * 35.9 = 44.9 A -> 45 A

CEC Inverters.csv for SolarJuice American Inc: S4A-A86 {240V}: Paco=8613.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=95.32%.

**Result:** Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for SolarJuice American Inc: S4A-A86 {240V}?

California Energy Commission Solar Equipment List parameters for SolarJuice American Inc: S4A-A86 {240V} (grid-tied PV inverter) interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for SolarJuice American Inc: S4A-A86 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 8,613 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 430 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 363 V - 430 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 22.7894 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 95.32% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for SolarJuice American Inc: S4A-A86 {240V}?

Panelboard and switchgear backfeed allowances for SolarJuice American Inc: S4A-A86 {240V} (45 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates SolarJuice American Inc: S4A-A86 {240V} (45 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 45 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 45 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 45 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 45 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 45 A | PASS (120% Rule) |

## Which Competing Grid-Support Inverters Compare to SolarJuice American Inc: S4A-A86 {240V}?

Four alternative CEC inverters matched to SolarJuice American Inc: S4A-A86 {240V} (8,613 W AC), led by ABB: UNO-86-TL-OUTD-S-US-A {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: UNO-86-TL-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-a-240v/) ABB | 8,600 W | -13 W | 240.0 V | 480.0 V | 97.03% |
| [**ABB: UNO-86-TL-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-z-a-240v/) ABB | 8,600 W | -13 W | 240.0 V | 480.0 V | 97.03% |
| [**ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-z-m-a-240v/) ABB | 8,600 W | -13 W | 240.0 V | 480.0 V | 97.03% |
| [**Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V}**](https://epri-peac.com/solar-equipment/inverters/afore-new-energy-technology-shanghai-co-ltd/afore-new-energy-technology-shanghai-co-ltd-af86k-dh-240v/) Afore New Energy Technology (Shanghai) Co Ltd | 8,596 W | -17 W | 240.0 V | 480.0 V | 97.91% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SolarJuice American Inc: S4A-A86 {240V}?

Check SolarJuice American Inc: S4A-A86 {240V} (8,613 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on SolarJuice American Inc: S4A-A86 {240V}.

### SolarJuice American Inc: S4A-A86 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (35.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (95.32%) and MPPT window (363-430 V) directly against ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarJuice American Inc: S4A-A86 {240V} by SolarJuice American Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does SolarJuice American Inc: S4A-A86 {240V} require?

At 8,613 W continuous AC (240 V), continuous current is 35.9 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

### Does SolarJuice American Inc: S4A-A86 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.

### How does SolarJuice American Inc: S4A-A86 {240V} compare to ABB: UNO-86-TL-OUTD-S-US-A {240V}?

SolarJuice American Inc: S4A-A86 {240V} delivers 8,613 W AC at 95.32% CEC efficiency with a 430 V DC ceiling, while ABB: UNO-86-TL-OUTD-S-US-A {240V} outputs 8,600 W at 240 V.

## Related Pages

Explore SolarJuice American Inc hardware, ABB: UNO-86-TL-OUTD-S-US-A {240V}, utility rates, and NEC 705.12 sizing calculators alongside SolarJuice American Inc: S4A-A86 {240V}.

[All SolarJuice American Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/solarjuice-american-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SolarJuice American Inc

- [All SolarJuice American Inc Specs](https://epri-peac.com/solar-equipment/brands/solarjuice-american-inc/)
- [SolarJuice American Inc: S4A-H86 {240V}](https://epri-peac.com/solar-equipment/inverters/solarjuice-american-inc/solarjuice-american-inc-s4a-h86-240v/)
- [SolarJuice American Inc: S4A-A76 {240V}](https://epri-peac.com/solar-equipment/inverters/solarjuice-american-inc/solarjuice-american-inc-s4a-a76-240v/)
- [SolarJuice American Inc: S4A-H76 {240V}](https://epri-peac.com/solar-equipment/inverters/solarjuice-american-inc/solarjuice-american-inc-s4a-h76-240v/)
- [SolarJuice American Inc: S4A-A70 {240V}](https://epri-peac.com/solar-equipment/inverters/solarjuice-american-inc/solarjuice-american-inc-s4a-a70-240v/)
- [SolarJuice American Inc: S4A-H70 {240V}](https://epri-peac.com/solar-equipment/inverters/solarjuice-american-inc/solarjuice-american-inc-s4a-h70-240v/)