Manufacturer: [**Solaria Corporation**](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) Registry: **CEC Verified Engineering Specification**

Solaria Corporation: Solaria PowerXT-350R-AC {240V} outputs 290 W AC at 240 V (1.2 A continuous, 15 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 27-45 V MPPT window and 45 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 290 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solaria Corporation: Solaria PowerXT-350R-AC {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,019), 27-45 V MPPT tracking, and panel fit for Solaria Corporation: Solaria PowerXT-350R-AC {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Solaria Corporation: Solaria PowerXT-350R-AC {240V} from Solaria Corporation outputs 1.2 A continuous AC at 240 V (290 W AC, rank #2,251). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 96.99% CEC efficiency compares closely with Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W). Keep NEC 690.7 winter string Voc below 45 V DC.

## Where Does Solaria Corporation: Solaria PowerXT-350R-AC {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Solaria Corporation: Solaria PowerXT-350R-AC {240V} at 290 W continuous AC output. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Dataset Percentiles Define Solaria Corporation: Solaria PowerXT-350R-AC {240V}?

Dataset percentiles comparing Solaria Corporation: Solaria PowerXT-350R-AC {240V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for Solaria Corporation: Solaria PowerXT-350R-AC {240V}?

Engineering highlights for Solaria Corporation: Solaria PowerXT-350R-AC {240V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #1,019 / 2,343

### 96.99% CEC Weighted Efficiency

+0.31 pts vs the 96.68% 240 V median; overall power rank #2,251 (290 W, below CEC median; higher than 2.0% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 1.2 A = 1.5 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 27 V - 45 V (Max 45 V DC)

Tracking span of 18.0 V; listed since 2019-05-01 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 290.0W / 240 V -> 1.2 A | Breaker >= 1.25 * 1.2 = 1.5 A -> 15 A

CEC Inverters.csv for Solaria Corporation: Solaria PowerXT-350R-AC {240V}: Paco=290.0 W, Vac=240 V, Vdcmax=45.0 V, Eff=96.99%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Solaria Corporation: Solaria PowerXT-350R-AC {240V}?

California Energy Commission Solar Equipment List parameters for Solaria Corporation: Solaria PowerXT-350R-AC {240V} (grid-tied PV inverter) interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation: Solaria PowerXT-350R-AC {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 290 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 45 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 27 V - 45 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 8.30546 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.99% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2019-05-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Solaria Corporation: Solaria PowerXT-350R-AC {240V}?

Panelboard and switchgear backfeed allowances for Solaria Corporation: Solaria PowerXT-350R-AC {240V} (15 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates Solaria Corporation: Solaria PowerXT-350R-AC {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Solaria Corporation: Solaria PowerXT-350R-AC {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Solaria Corporation: Solaria PowerXT-350R-AC {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 27.0-45.0 V MPPT and 45.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-0-270tw/) | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |

## Which Competing Grid-Support Inverters Compare to Solaria Corporation: Solaria PowerXT-350R-AC {240V}?

Four alternative CEC inverters matched to Solaria Corporation: Solaria PowerXT-350R-AC {240V} (290 W AC), led by Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}**](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-250e-60-72-208-240-mc4-240v/) Chilicon Power LLC | 289 W | -1 W | 240.0 V | 32.0 V | 95.41% |
| [**Aptos Solar Technology LLC: MAC-400 {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400-240v/) Aptos Solar Technology LLC | 382 W | +92 W | 240.0 V | 48.0 V | 96.52% |
| [**Aptos Solar Technology LLC: MAC-400R {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400r-240v/) Aptos Solar Technology LLC | 382 W | +92 W | 240.0 V | 48.0 V | 96.52% |
| [**Altenergy Power System Inc: YC600 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-yc600-240v/) Altenergy Power System Inc | 550 W | +260 W | 240.0 V | 45.0 V | 96.51% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Solaria Corporation: Solaria PowerXT-350R-AC {240V}?

Check Solaria Corporation: Solaria PowerXT-350R-AC {240V} (290 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 45 V DC on Solaria Corporation: Solaria PowerXT-350R-AC {240V}.

### Solaria Corporation: Solaria PowerXT-350R-AC {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.99%) and MPPT window (27-45 V) directly against Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Solaria Corporation: Solaria PowerXT-350R-AC {240V} by Solaria Corporation covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Solaria Corporation: Solaria PowerXT-350R-AC {240V} require?

At 290 W continuous AC (240 V), continuous current is 1.2 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Solaria Corporation: Solaria PowerXT-350R-AC {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Solaria Corporation: Solaria PowerXT-350R-AC {240V} compare to Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Solaria Corporation: Solaria PowerXT-350R-AC {240V} delivers 290 W AC at 96.99% CEC efficiency with a 45 V DC ceiling, while Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} outputs 289 W at 240 V.

## Related Pages

Explore Solaria Corporation hardware, Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Solaria Corporation: Solaria PowerXT-350R-AC {240V}.

[All Solaria Corporation Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solaria Corporation

- [All Solaria Corporation Specs](https://epri-peac.com/solar-equipment/brands/solaria-corporation/)
- [Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-395r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-400R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-400r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-410R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-410r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-420r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-345R-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-345r-ac-240v/)