title: "Solaria Corporation: Solaria Inverter (290W)"
url: https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-345r-ac-240v/
description: "CEC specs for Solaria Corporation: Solaria PowerXT-345R-AC {240V}: 290W AC, 240V, 15A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Solaria Corporation: Solaria PowerXT-345R-AC {240V} — CEC Inverter Specifications

Manufacturer: [**Solaria Corporation**](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) Registry: **CEC Verified Engineering Specification**

Solaria Corporation: Solaria PowerXT-345R-AC {240V} outputs 290 W AC at 240 V (1.2 A continuous, 15 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 27-45 V MPPT window and 45 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 290 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solaria Corporation: Solaria PowerXT-345R-AC {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,019), 27-45 V MPPT tracking, and panel fit for Solaria Corporation: Solaria PowerXT-345R-AC {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Operating at 240 V, Solaria Corporation: Solaria PowerXT-345R-AC {240V} converts DC array energy at 96.99% CEC weighted efficiency (top 44.5%; higher than 55.5% of peers) with a 45 V max DC input and 8.30546 A max input current for NEC 690.7 string safety. Compare this 290 W grid-tied PV inverter directly with Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.

## Where Does Solaria Corporation: Solaria PowerXT-345R-AC {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Solaria Corporation: Solaria PowerXT-345R-AC {240V} at 290 W continuous AC output. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Dataset Percentiles Define Solaria Corporation: Solaria PowerXT-345R-AC {240V}?

Dataset percentiles comparing Solaria Corporation: Solaria PowerXT-345R-AC {240V} against 2,343 certified grid-support inverters nationwide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Do the Dataset Ranks Show for Solaria Corporation: Solaria PowerXT-345R-AC {240V}?

Engineering highlights for Solaria Corporation: Solaria PowerXT-345R-AC {240V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #1,019 / 2,343

### 96.99% CEC Weighted Efficiency

+0.31 pts vs the 96.68% 240 V median; overall power rank #2,251 (290 W, below CEC median; higher than 2.0% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 1.2 A = 1.5 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 27 V - 45 V (Max 45 V DC)

Tracking span of 18.0 V; listed since 2019-05-01 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 290.0W / 240 V -> 1.2 A | Breaker >= 1.25 * 1.2 = 1.5 A -> 15 A

CEC Inverters.csv for Solaria Corporation: Solaria PowerXT-345R-AC {240V}: Paco=290.0 W, Vac=240 V, Vdcmax=45.0 V, Eff=96.99%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Solaria Corporation: Solaria PowerXT-345R-AC {240V}?

California Energy Commission Solar Equipment List parameters for Solaria Corporation: Solaria PowerXT-345R-AC {240V} (grid-tied PV inverter) interconnection. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation: Solaria PowerXT-345R-AC {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 290 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 45 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 27 V - 45 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 8.30546 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.99% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2019-05-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Solaria Corporation: Solaria PowerXT-345R-AC {240V}?

Panelboard and switchgear backfeed allowances for Solaria Corporation: Solaria PowerXT-345R-AC {240V} (15 A OCPD). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Evaluates Solaria Corporation: Solaria PowerXT-345R-AC {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Solaria Corporation: Solaria PowerXT-345R-AC {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Solaria Corporation: Solaria PowerXT-345R-AC {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 27.0-45.0 V MPPT and 45.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-0-270tw/) | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |

## Which Competing Grid-Support Inverters Compare to Solaria Corporation: Solaria PowerXT-345R-AC {240V}?

Four alternative CEC inverters matched to Solaria Corporation: Solaria PowerXT-345R-AC {240V} (290 W AC), led by Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}**](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-250e-60-72-208-240-mc4-240v/) Chilicon Power LLC | 289 W | -1 W | 240.0 V | 32.0 V | 95.41% |
| [**Aptos Solar Technology LLC: MAC-400 {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400-240v/) Aptos Solar Technology LLC | 382 W | +92 W | 240.0 V | 48.0 V | 96.52% |
| [**Aptos Solar Technology LLC: MAC-400R {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400r-240v/) Aptos Solar Technology LLC | 382 W | +92 W | 240.0 V | 48.0 V | 96.52% |
| [**Altenergy Power System Inc: YC600 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-yc600-240v/) Altenergy Power System Inc | 550 W | +260 W | 240.0 V | 45.0 V | 96.51% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Solaria Corporation: Solaria PowerXT-345R-AC {240V}?

Check Solaria Corporation: Solaria PowerXT-345R-AC {240V} (290 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 45 V DC on Solaria Corporation: Solaria PowerXT-345R-AC {240V}.

### Solaria Corporation: Solaria PowerXT-345R-AC {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.99%) and MPPT window (27-45 V) directly against Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Solaria Corporation: Solaria PowerXT-345R-AC {240V} by Solaria Corporation covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Solaria Corporation: Solaria PowerXT-345R-AC {240V} require?

At 290 W continuous AC (240 V), continuous current is 1.2 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Solaria Corporation: Solaria PowerXT-345R-AC {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Solaria Corporation: Solaria PowerXT-345R-AC {240V} compare to Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Solaria Corporation: Solaria PowerXT-345R-AC {240V} delivers 290 W AC at 96.99% CEC efficiency with a 45 V DC ceiling, while Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} outputs 289 W at 240 V.

## Related Pages

Explore Solaria Corporation hardware, Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Solaria Corporation: Solaria PowerXT-345R-AC {240V}.

[All Solaria Corporation Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solaria Corporation

- [All Solaria Corporation Specs](https://epri-peac.com/solar-equipment/brands/solaria-corporation/)
- [Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-395r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-400R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-400r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-410R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-410r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-420r-pm-ac-240v/)
- [Solaria Corporation: Solaria PowerXT-350R-AC {240V}](https://epri-peac.com/solar-equipment/inverters/solaria-corporation/solaria-corporation-solaria-powerxt-350r-ac-240v/)