title: "SolarEdge Technologies Ltd Inverter (13,000W)"
url: https://epri-peac.com/solar-equipment/inverters/solaredge-technologies-ltd/solaredge-technologies-ltd-nx13000t-us-240v/
description: "CEC specs for SolarEdge Technologies Ltd: NX13000T-US {240V}: 13,000W AC, 240V, 70A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# SolarEdge Technologies Ltd: NX13000T-US {240V} — CEC Inverter Specifications

Manufacturer: [**SolarEdge Technologies Ltd**](https://epri-peac.com/solar-equipment/brands/solaredge-technologies-ltd/) Registry: **CEC Verified Engineering Specification**

SolarEdge Technologies Ltd: NX13000T-US {240V} outputs 13,000 W AC at 240 V (54.2 A continuous, 70 A OCPD), ranking #86 of 2,343 CEC inverters at 98.47% efficiency with a 370-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 13,000 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 70 A (4 AWG Cu)

- **CEC Efficiency** : 98.47%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SolarEdge Technologies Ltd: NX13000T-US {240V} Compare Against Peer CEC Listings?

How SolarEdge Technologies Ltd SolarEdge Technologies Ltd: NX13000T-US {240V} compares on 98.47% efficiency, MPPT span, and 120% busbar interconnection.

SolarEdge Technologies Ltd certifies SolarEdge Technologies Ltd: NX13000T-US {240V} (hybrid battery-capable inverter, active in CEC directory) at 13,000 W AC (7,224 W above the 5,776 W 240 V median). Its 450 V DC ceiling pairs with an MPPT window of 370-450 V (span 80.0 V). Under NEC 690.8/705.12, 125% sizing demands 4 AWG Cu conductors on a 70 A OCPD.

## Where Does SolarEdge Technologies Ltd: NX13000T-US {240V} Fall Across Listed CEC Models?

Position of SolarEdge Technologies Ltd: NX13000T-US {240V} (13,000 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define SolarEdge Technologies Ltd: NX13000T-US {240V}?

Percentile placement of SolarEdge Technologies Ltd: NX13000T-US {240V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: NX13000T-US {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SolarEdge Technologies Ltd: NX13000T-US {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Eff #86 / 2,343

### 98.47% CEC Weighted Efficiency

+1.79 pts vs the 96.68% 240 V median; overall power rank #694 (13,000 W, top 29.7%; higher than 70.3% of peers).

NEC 705.12 Check

### 70 A Required Backfeed OCPD

125% x 54.2 A = 67.8 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 370 V - 450 V (Max 450 V DC)

Tracking span of 80.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 13000.0W / 240 V -> 54.2 A | Breaker >= 1.25 * 54.2 = 67.8 A -> 70 A

CEC Inverters.csv for SolarEdge Technologies Ltd: NX13000T-US {240V}: Paco=13000.0 W, Vac=240 V, Vdcmax=450.0 V, Eff=98.47%.

**Result:** Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for SolarEdge Technologies Ltd: NX13000T-US {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SolarEdge Technologies Ltd: NX13000T-US {240V}.

Official California Energy Commission (NREL SAM) test parameters for SolarEdge Technologies Ltd: NX13000T-US {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 13,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 450 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 370 V - 450 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 33.424 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.47% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for SolarEdge Technologies Ltd: NX13000T-US {240V}?

Check whether SolarEdge Technologies Ltd: NX13000T-US {240V} (70 A breaker) fits without main breaker derate or supply-side taps.

Evaluates SolarEdge Technologies Ltd: NX13000T-US {240V} (70 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 70 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 70 A | Needs Derate / Tap 705.11 |
| **225A Bus / 200A Main** | 70 A | 70 A | PASS (120% Rule) |

## Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: NX13000T-US {240V}?

Alternative CEC inverters comparable to SolarEdge Technologies Ltd: NX13000T-US {240V}, including Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Amensolar Ess Co Ltd: N3H-X12US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x12us-240v/) Amensolar Ess Co Ltd | 12,214 W | -786 W | 240.0 V | 430.0 V | 96.17% |
| [**Chint Power Systems America: CPS ECH12KTL/US {240V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-240v/) Chint Power Systems America | 11,990 W | -1010 W | 240.0 V | 480.0 V | 96.59% |
| [**Delta Electronics: S12_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-s12-bdi-240v/) Delta Electronics | 11,589 W | -1411 W | 240.0 V | 480.0 V | 96.99% |
| [**Base Power Inc: MIN 11400TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/) Base Power Inc | 11,520 W | -1480 W | 240.0 V | 480.0 V | 97.76% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: NX13000T-US {240V}?

Check SolarEdge Technologies Ltd: NX13000T-US {240V} (13,000 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on SolarEdge Technologies Ltd: NX13000T-US {240V}.

### SolarEdge Technologies Ltd: NX13000T-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (54.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.47%) and MPPT window (370-450 V) directly against Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarEdge Technologies Ltd: NX13000T-US {240V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does SolarEdge Technologies Ltd: NX13000T-US {240V} require?

At 13,000 W continuous AC (240 V), continuous current is 54.2 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

### Does SolarEdge Technologies Ltd: NX13000T-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

### How does SolarEdge Technologies Ltd: NX13000T-US {240V} compare to Amensolar Ess Co Ltd: N3H-X12US {240V}?

SolarEdge Technologies Ltd: NX13000T-US {240V} delivers 13,000 W AC at 98.47% CEC efficiency with a 450 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X12US {240V} outputs 12,214 W at 240 V.

## Related Pages

Explore SolarEdge Technologies Ltd hardware, Amensolar Ess Co Ltd: N3H-X12US {240V}, utility rates, and NEC 705.12 sizing calculators alongside SolarEdge Technologies Ltd: NX13000T-US {240V}.

[All SolarEdge Technologies Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/solaredge-technologies-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SolarEdge Technologies Ltd

- [All SolarEdge Technologies Ltd Specs](https://epri-peac.com/solar-equipment/brands/solaredge-technologies-ltd/)
- [SolarEdge Technologies Ltd: SE330KUS {690V}](https://epri-peac.com/solar-equipment/inverters/solaredge-technologies-ltd/solaredge-technologies-ltd-se330kus-690v/)
- [SolarEdge Technologies Ltd: SE285KUS {600V}](https://epri-peac.com/solar-equipment/inverters/solaredge-technologies-ltd/solaredge-technologies-ltd-se285kus-600v/)
- [SolarEdge Technologies Ltd: SE250KUS {600V}](https://epri-peac.com/solar-equipment/inverters/solaredge-technologies-ltd/solaredge-technologies-ltd-se250kus-600v/)
- [SolarEdge Technologies Ltd: SE110KUS {480V}](https://epri-peac.com/solar-equipment/inverters/solaredge-technologies-ltd/solaredge-technologies-ltd-se110kus-480v/)
- [SolarEdge Technologies Ltd: SE120KUS {480V}](https://epri-peac.com/solar-equipment/inverters/solaredge-technologies-ltd/solaredge-technologies-ltd-se120kus-480v/)