title: "Sol-Ark: Sol-Ark-8k-48-ST {240V} Inverter (8,818W)"
url: https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-sol-ark-8k-48-st-240v/
description: "CEC specs for Sol-Ark: Sol-Ark-8k-48-ST {240V}: 8,818W AC, 240V, 50A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Sol-Ark: Sol-Ark-8k-48-ST {240V} — CEC Inverter Specifications

Manufacturer: [**Sol-Ark**](https://epri-peac.com/solar-equipment/brands/sol-ark/) Registry: **CEC Verified Engineering Specification**

Sol-Ark: Sol-Ark-8k-48-ST {240V} outputs 8,818 W AC at 240 V (36.7 A continuous, 50 A OCPD), ranking #1,083 of 2,343 CEC inverters at 96.95% efficiency with a 240-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 8,818 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 50 A (8 AWG Cu)

- **CEC Efficiency** : 96.95%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sol-Ark: Sol-Ark-8k-48-ST {240V} Compare Against Peer CEC Listings?

How Sol-Ark Sol-Ark: Sol-Ark-8k-48-ST {240V} compares on 96.95% efficiency, MPPT span, and 120% busbar interconnection. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

With a 240-425 V MPPT tracking band and 425 V DC ceiling, Sol-Ark: Sol-Ark-8k-48-ST {240V} handles 8,818 W continuous AC (3,042 W above the 5,776 W 240 V median). Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Installers comparing Sol-Ark against ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W) should verify whether listed since 2023-04-11 grid-support firmware meets local IEEE 1547 utility rules.

## Where Does Sol-Ark: Sol-Ark-8k-48-ST {240V} Fall Across Listed CEC Models?

Position of Sol-Ark: Sol-Ark-8k-48-ST {240V} (8,818 W AC) relative to the 7,680 W CEC median inverter. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Dataset Percentiles Define Sol-Ark: Sol-Ark-8k-48-ST {240V}?

Percentile placement of Sol-Ark: Sol-Ark-8k-48-ST {240V} across AC power class, conversion efficiency, and backfeed breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Do the Dataset Ranks Show for Sol-Ark: Sol-Ark-8k-48-ST {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Sol-Ark: Sol-Ark-8k-48-ST {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Eff #1,083 / 2,343

### 96.95% CEC Weighted Efficiency

+0.27 pts vs the 96.68% 240 V median; overall power rank #1,030 (8,818 W, top 44.0%; higher than 56.0% of peers).

NEC 705.12 Check

### 50 A Required Backfeed OCPD

125% x 36.7 A = 45.9 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 240 V - 425 V (Max 425 V DC)

Tracking span of 185.0 V; listed since 2023-04-11 (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8818.1W / 240 V -> 36.7 A | Breaker >= 1.25 * 36.7 = 45.9 A -> 50 A

CEC Inverters.csv for Sol-Ark: Sol-Ark-8k-48-ST {240V}: Paco=8818.1 W, Vac=240 V, Vdcmax=425.0 V, Eff=96.95%.

**Result:** Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Sol-Ark: Sol-Ark-8k-48-ST {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Sol-Ark: Sol-Ark-8k-48-ST {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for Sol-Ark: Sol-Ark-8k-48-ST {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 8,818 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 425 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 240 V - 425 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 24.5835 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.95% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2023-04-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Sol-Ark: Sol-Ark-8k-48-ST {240V}?

Check whether Sol-Ark: Sol-Ark-8k-48-ST {240V} (50 A breaker) fits without main breaker derate or supply-side taps. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates Sol-Ark: Sol-Ark-8k-48-ST {240V} (50 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 50 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 50 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 50 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 50 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 50 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Sol-Ark: Sol-Ark-8k-48-ST {240V}?

Verified cold-weather (-10 C) series module counts matched to Sol-Ark: Sol-Ark-8k-48-ST {240V}'s 425 V DC ceiling. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 240.0-425.0 V MPPT and 425.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 8 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 7 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 9 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to Sol-Ark: Sol-Ark-8k-48-ST {240V}?

Alternative CEC inverters comparable to Sol-Ark: Sol-Ark-8k-48-ST {240V}, including ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W) at 240 V. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: UNO-86-TL-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-a-240v/) ABB | 8,600 W | -218 W | 240.0 V | 480.0 V | 97.03% |
| [**ABB: UNO-86-TL-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-z-a-240v/) ABB | 8,600 W | -218 W | 240.0 V | 480.0 V | 97.03% |
| [**ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-z-m-a-240v/) ABB | 8,600 W | -218 W | 240.0 V | 480.0 V | 97.03% |
| [**Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V}**](https://epri-peac.com/solar-equipment/inverters/afore-new-energy-technology-shanghai-co-ltd/afore-new-energy-technology-shanghai-co-ltd-af86k-dh-240v/) Afore New Energy Technology (Shanghai) Co Ltd | 8,596 W | -222 W | 240.0 V | 480.0 V | 97.91% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Sol-Ark: Sol-Ark-8k-48-ST {240V}?

Check Sol-Ark: Sol-Ark-8k-48-ST {240V} (8,818 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Sol-Ark: Sol-Ark-8k-48-ST {240V}.

### Sol-Ark: Sol-Ark-8k-48-ST {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (36.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.95%) and MPPT window (240-425 V) directly against ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sol-Ark: Sol-Ark-8k-48-ST {240V} by Sol-Ark covering breaker sizing, MPPT limits, and 240 V interconnection. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

### What breaker and wire size does Sol-Ark: Sol-Ark-8k-48-ST {240V} require?

At 8,818 W continuous AC (240 V), continuous current is 36.7 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

### Does Sol-Ark: Sol-Ark-8k-48-ST {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.

### How does Sol-Ark: Sol-Ark-8k-48-ST {240V} compare to ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Sol-Ark: Sol-Ark-8k-48-ST {240V} delivers 8,818 W AC at 96.95% CEC efficiency with a 425 V DC ceiling, while ABB: UNO-86-TL-OUTD-S-US-A {240V} outputs 8,600 W at 240 V.

## Related Pages

Explore Sol-Ark hardware, ABB: UNO-86-TL-OUTD-S-US-A {240V}, utility rates, and NEC 705.12 sizing calculators alongside Sol-Ark: Sol-Ark-8k-48-ST {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

[All Sol-Ark Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sol-ark/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sol-Ark

- [All Sol-Ark Specs](https://epri-peac.com/solar-equipment/brands/sol-ark/)
- [Sol-Ark: 60K-3P-480V {277V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-60k-3p-480v-277v/)
- [Sol-Ark: 30K-3P-208V {120V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-30k-3p-208v-120v/)
- [Sol-Ark: Limitless 18K-2P-LV {240V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-18k-2p-lv-240v/)
- [Sol-Ark: Limitless 18K-2P-LV {208V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-18k-2p-lv-208v/)
- [Sol-Ark: Limitless 15K-LV {240V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-15k-lv-240v/)