title: "Sol-Ark: 5K-120V/8K-230V-1P {240V} Inverter (7,970W)"
url: https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-5k-120v-8k-230v-1p-240v/
description: "CEC specs for Sol-Ark: 5K-120V/8K-230V-1P {240V}: 7,970W AC, 240V, 45A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Sol-Ark: 5K-120V/8K-230V-1P {240V} — CEC Inverter Specifications

Manufacturer: [**Sol-Ark**](https://epri-peac.com/solar-equipment/brands/sol-ark/) Registry: **CEC Verified Engineering Specification**

Sol-Ark: 5K-120V/8K-230V-1P {240V} outputs 7,970 W AC at 240 V (33.2 A continuous, 45 A OCPD), ranking #2,145 of 2,343 CEC inverters at 95.58% efficiency with a 200-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 7,970 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 45 A (8 AWG Cu)

- **CEC Efficiency** : 95.58%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sol-Ark: 5K-120V/8K-230V-1P {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,145), 200-425 V MPPT tracking, and panel fit for Sol-Ark: 5K-120V/8K-230V-1P {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Operating at 240 V, Sol-Ark: 5K-120V/8K-230V-1P {240V} converts DC array energy at 95.58% CEC weighted efficiency (below overall CEC median; higher than 8.4% of peers) with a 425 V max DC input and 26.6834 A max input current for NEC 690.7 string safety. Compare this 7,970 W hybrid battery-capable inverter directly with Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V} (7,999 W). Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.

## Where Does Sol-Ark: 5K-120V/8K-230V-1P {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Sol-Ark: 5K-120V/8K-230V-1P {240V} at 7,970 W continuous AC output. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define Sol-Ark: 5K-120V/8K-230V-1P {240V}?

Dataset percentiles comparing Sol-Ark: 5K-120V/8K-230V-1P {240V} against 2,343 certified grid-support inverters nationwide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Do the Dataset Ranks Show for Sol-Ark: 5K-120V/8K-230V-1P {240V}?

Engineering highlights for Sol-Ark: 5K-120V/8K-230V-1P {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #2,145 / 2,343

### 95.58% CEC Weighted Efficiency

-1.10 pts vs the 96.68% 240 V median; overall power rank #1,129 (7,970 W, top 48.2%; higher than 51.8% of peers).

NEC 705.12 Check

### 45 A Required Backfeed OCPD

125% x 33.2 A = 41.5 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 200 V - 425 V (Max 425 V DC)

Tracking span of 225.0 V; listed since 2024-05-13 (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7970.3W / 240 V -> 33.2 A | Breaker >= 1.25 * 33.2 = 41.5 A -> 45 A

CEC Inverters.csv for Sol-Ark: 5K-120V/8K-230V-1P {240V}: Paco=7970.3 W, Vac=240 V, Vdcmax=425.0 V, Eff=95.58%.

**Result:** Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Sol-Ark: 5K-120V/8K-230V-1P {240V}?

California Energy Commission Solar Equipment List parameters for Sol-Ark: 5K-120V/8K-230V-1P {240V} (hybrid battery-capable inverter) interconnection. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Sol-Ark: 5K-120V/8K-230V-1P {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 7,970 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 425 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 425 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 26.6834 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 95.58% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-05-13 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Sol-Ark: 5K-120V/8K-230V-1P {240V}?

Panelboard and switchgear backfeed allowances for Sol-Ark: 5K-120V/8K-230V-1P {240V} (45 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Evaluates Sol-Ark: 5K-120V/8K-230V-1P {240V} (45 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 45 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 45 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 45 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 45 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 45 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Sol-Ark: 5K-120V/8K-230V-1P {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Sol-Ark: 5K-120V/8K-230V-1P {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sampled CEC PV modules aligned within 200.0-425.0 V MPPT and 425.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to Sol-Ark: 5K-120V/8K-230V-1P {240V}?

Four alternative CEC inverters matched to Sol-Ark: 5K-120V/8K-230V-1P {240V} (7,970 W AC), led by Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}**](https://epri-peac.com/solar-equipment/inverters/afore-new-energy-technology-shanghai-co-ltd/afore-new-energy-technology-shanghai-co-ltd-af8k-dh-240v/) Afore New Energy Technology (Shanghai) Co Ltd | 7,999 W | +29 W | 240.0 V | 480.0 V | 97.79% |
| [**Amensolar Ess Co Ltd: N3H-X80-US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x80-us-240v/) Amensolar Ess Co Ltd | 8,084 W | +114 W | 240.0 V | 430.0 V | 97.08% |
| [**Amensolar Ess Co Ltd: N3H-X8US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x8us-240v/) Amensolar Ess Co Ltd | 8,084 W | +114 W | 240.0 V | 430.0 V | 97.08% |
| [**Amensolar Ess Co Ltd: N3H-X76-US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x76-us-240v/) Amensolar Ess Co Ltd | 7,765 W | -205 W | 240.0 V | 430.0 V | 97.14% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Sol-Ark: 5K-120V/8K-230V-1P {240V}?

Check Sol-Ark: 5K-120V/8K-230V-1P {240V} (7,970 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Sol-Ark: 5K-120V/8K-230V-1P {240V}.

### Sol-Ark: 5K-120V/8K-230V-1P {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (33.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (95.58%) and MPPT window (200-425 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V} (7,999 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sol-Ark: 5K-120V/8K-230V-1P {240V} by Sol-Ark covering breaker sizing, MPPT limits, and 240 V interconnection. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

### What breaker and wire size does Sol-Ark: 5K-120V/8K-230V-1P {240V} require?

At 7,970 W continuous AC (240 V), continuous current is 33.2 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

### Does Sol-Ark: 5K-120V/8K-230V-1P {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.

### How does Sol-Ark: 5K-120V/8K-230V-1P {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}?

Sol-Ark: 5K-120V/8K-230V-1P {240V} delivers 7,970 W AC at 95.58% CEC efficiency with a 425 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V} outputs 7,999 W at 240 V.

## Related Pages

Explore Sol-Ark hardware, Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}, utility rates, and NEC 705.12 sizing calculators alongside Sol-Ark: 5K-120V/8K-230V-1P {240V}.

[All Sol-Ark Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sol-ark/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sol-Ark

- [All Sol-Ark Specs](https://epri-peac.com/solar-equipment/brands/sol-ark/)
- [Sol-Ark: 60K-3P-480V {277V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-60k-3p-480v-277v/)
- [Sol-Ark: 30K-3P-208V {120V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-30k-3p-208v-120v/)
- [Sol-Ark: Limitless 18K-2P-LV {240V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-18k-2p-lv-240v/)
- [Sol-Ark: Limitless 18K-2P-LV {208V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-18k-2p-lv-208v/)
- [Sol-Ark: Limitless 15K-LV {240V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-15k-lv-240v/)