---
title: "Sol-Ark: 5K-120V/8K-230V-1P {120V} Inverter (4,787W)"
url: https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-5k-120v-8k-230v-1p-120v/
description: "CEC specs for Sol-Ark: 5K-120V/8K-230V-1P {120V}: 4,787W AC, 120V, 50A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Sol-Ark: 5K-120V/8K-230V-1P {120V} — CEC Inverter Specifications

Manufacturer: [**Sol-Ark**](https://epri-peac.com/solar-equipment/brands/sol-ark/) Registry: **CEC Verified Engineering Specification**

Sol-Ark: 5K-120V/8K-230V-1P {120V} outputs 4,787 W AC at 120 V (39.9 A continuous, 50 A OCPD), ranking #2,141 of 2,343 CEC inverters at 95.59% efficiency with a 200-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 4,787 W

- **AC Voltage** : 120 V

- **Min PV Breaker** : 50 A (8 AWG Cu)

- **CEC Efficiency** : 95.59%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sol-Ark: 5K-120V/8K-230V-1P {120V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 120 V grid-support overview for Sol-Ark: 5K-120V/8K-230V-1P {120V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Ranking #1,577 of 2,343 CEC inverters (below CEC median; higher than 32.7% of peers), Sol-Ark: 5K-120V/8K-230V-1P {120V} is a hybrid battery-capable inverter delivering 4,787 W continuous AC at 120 V (39.9 A continuous). Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 95.59% (+0.86 pts vs the 94.73% 120 V median) against peers like Power Center: Essential Hybrid 5 {120V} (4,787 W).

## Where Does Sol-Ark: 5K-120V/8K-230V-1P {120V} Fall Across Listed CEC Models?

Marks Sol-Ark: 5K-120V/8K-230V-1P {120V} (4,787 W AC) across the California Energy Commission inverter AC capacity distribution. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define Sol-Ark: 5K-120V/8K-230V-1P {120V}?

Benchmarks Sol-Ark: 5K-120V/8K-230V-1P {120V} continuous AC output, 95.59% CEC weighted efficiency, and 50 A OCPD breaker demand.

## What Do the Dataset Ranks Show for Sol-Ark: 5K-120V/8K-230V-1P {120V}?

Four key NEC 705.12 and California Energy Commission metrics defining Sol-Ark: 5K-120V/8K-230V-1P {120V} by Sol-Ark. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Eff #2,141 / 2,343

### 95.59% CEC Weighted Efficiency

+0.86 pts vs the 94.73% 120 V median; overall power rank #1,577 (4,787 W, below CEC median; higher than 32.7% of peers).

NEC 705.12 Check

### 50 A Required Backfeed OCPD

125% x 39.9 A = 49.9 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 200 V - 425 V (Max 425 V DC)

Tracking span of 225.0 V; listed since 2024-05-13 (hybrid battery-capable inverter).

Panel Fit (240V)

### 120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4787.1W / 120 V -> 39.9 A | Breaker >= 1.25 * 39.9 = 49.9 A -> 50 A

CEC Inverters.csv for Sol-Ark: 5K-120V/8K-230V-1P {120V}: Paco=4787.1 W, Vac=120 V, Vdcmax=425.0 V, Eff=95.59%.

**Result:** Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

## What Are the Published CEC Specifications for Sol-Ark: 5K-120V/8K-230V-1P {120V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Sol-Ark: 5K-120V/8K-230V-1P {120V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Sol-Ark: 5K-120V/8K-230V-1P {120V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 4,787 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 120 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 425 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 425 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 16.0262 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 95.59% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-05-13 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Sol-Ark: 5K-120V/8K-230V-1P {120V}?

Evaluates Sol-Ark: 5K-120V/8K-230V-1P {120V} (50 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Sol-Ark: 5K-120V/8K-230V-1P {120V} (50 A required OCPD at 120 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 50 A | 120V AC Coupled / Dedicated Transformer |
| **150A Bus / 150A Main** | 30 A | 50 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 200A Main** | 40 A | 50 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 175A Main** | 65 A | 50 A | 120V AC Coupled / Dedicated Transformer |
| **225A Bus / 200A Main** | 70 A | 50 A | 120V AC Coupled / Dedicated Transformer |

## Which CEC PV Module Strings Pair With Sol-Ark: 5K-120V/8K-230V-1P {120V}?

Sample PV string lengths aligned within 200-425 V MPPT and 425 V DC max at -10 C. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sampled CEC PV modules aligned within 200.0-425.0 V MPPT and 425.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to Sol-Ark: 5K-120V/8K-230V-1P {120V}?

Competing CEC grid-support inverters near 4,787 W AC and 120 V, led by Power Center: Essential Hybrid 5 {120V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Power Center: Essential Hybrid 5 {120V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-essential-hybrid-5-120v/) Power Center | 4,787 W | Tie (0 W) | 120.0 V | 425.0 V | 95.59% |
| [**Schneider Electric USA Inc: XW Pro 6848 NA {120V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-xw-pro-6848-na-120v/) Schneider Electric USA Inc | 5,747 W | +960 W | 120.0 V | 58.0 V | 91.96% |
| [**Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V}**](https://epri-peac.com/solar-equipment/inverters/fengfan-co-ltd-power-supply-branch/fengfan-co-ltd-power-supply-branch-spt-omobfp1-a-6kw-120v/) Fengfan Co Ltd Power Supply Branch | 6,018 W | +1231 W | 120.0 V | 500.0 V | 94.55% |
| [**SimpliPhi Power: SPHI-IN-6 {120V}**](https://epri-peac.com/solar-equipment/inverters/simpliphi-power/simpliphi-power-sphi-in-6-120v/) SimpliPhi Power | 6,018 W | +1231 W | 120.0 V | 500.0 V | 94.55% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Sol-Ark: 5K-120V/8K-230V-1P {120V}?

Check Sol-Ark: 5K-120V/8K-230V-1P {120V} (4,787 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Sol-Ark: 5K-120V/8K-230V-1P {120V}.

### Sol-Ark: 5K-120V/8K-230V-1P {120V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (39.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (95.59%) and MPPT window (200-425 V) directly against Power Center: Essential Hybrid 5 {120V} (4,787 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sol-Ark: 5K-120V/8K-230V-1P {120V} by Sol-Ark covering breaker sizing, MPPT limits, and 120 V interconnection. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

### What breaker and wire size does Sol-Ark: 5K-120V/8K-230V-1P {120V} require?

At 4,787 W continuous AC (120 V), continuous current is 39.9 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

### Does Sol-Ark: 5K-120V/8K-230V-1P {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 120 V means 120V AC Coupled / Dedicated Transformer.

### How does Sol-Ark: 5K-120V/8K-230V-1P {120V} compare to Power Center: Essential Hybrid 5 {120V}?

Sol-Ark: 5K-120V/8K-230V-1P {120V} delivers 4,787 W AC at 95.59% CEC efficiency with a 425 V DC ceiling, while Power Center: Essential Hybrid 5 {120V} outputs 4,787 W at 120 V.

## Related Pages

Explore Sol-Ark hardware, Power Center: Essential Hybrid 5 {120V}, utility rates, and NEC 705.12 sizing calculators alongside Sol-Ark: 5K-120V/8K-230V-1P {120V}.

[All Sol-Ark Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sol-ark/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sol-Ark

- [All Sol-Ark Specs](https://epri-peac.com/solar-equipment/brands/sol-ark/)
- [Sol-Ark: 60K-3P-480V {277V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-60k-3p-480v-277v/)
- [Sol-Ark: 30K-3P-208V {120V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-30k-3p-208v-120v/)
- [Sol-Ark: Limitless 18K-2P-LV {240V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-18k-2p-lv-240v/)
- [Sol-Ark: Limitless 18K-2P-LV {208V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-18k-2p-lv-208v/)
- [Sol-Ark: Limitless 15K-LV {240V}](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-limitless-15k-lv-240v/)
