title: "SMA America: STPS60US-20 {480V} Inverter (60,000W)"
url: https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-stps60us-20-480v/
description: "CEC specs for SMA America: STPS60US-20 {480V}: 60,000W AC, 480V, 100A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# SMA America: STPS60US-20 {480V} — CEC Inverter Specifications

Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: STPS60US-20 {480V} outputs 60,000 W AC at 480 V, 3-phase (72.2 A continuous, 100 A OCPD), ranking #522 of 2,343 CEC inverters at 97.57% efficiency with a 415-980 V MPPT window and 980 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 60,000 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 100 A (3 AWG Cu)

- **CEC Efficiency** : 97.57%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: STPS60US-20 {480V} Compare Against Peer CEC Listings?

CEC efficiency rank (#522), 415-980 V MPPT tracking, and panel fit for SMA America: STPS60US-20 {480V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Operating at 480 V, 3-phase, SMA America: STPS60US-20 {480V} converts DC array energy at 97.57% CEC weighted efficiency (top 22.4%; higher than 77.6% of peers) with a 980 V max DC input and 79.3484 A max input current for NEC 690.7 string safety. Compare this 60,000 W grid-tied PV inverter directly with ABB: TRIO-600-TL-OUTD-US-480 {480V} (60,000 W). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.

## Where Does SMA America: STPS60US-20 {480V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SMA America: STPS60US-20 {480V} at 60,000 W continuous AC output. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define SMA America: STPS60US-20 {480V}?

Dataset percentiles comparing SMA America: STPS60US-20 {480V} against 2,343 certified grid-support inverters nationwide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Do the Dataset Ranks Show for SMA America: STPS60US-20 {480V}?

Engineering highlights for SMA America: STPS60US-20 {480V} covering efficiency, 3 AWG Cu feeder, and panel compatibility. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Eff #522 / 2,343

### 97.57% CEC Weighted Efficiency

-0.45 pts vs the 98.02% 480 V median; overall power rank #408 (60,000 W, top 17.8%; higher than 82.2% of peers).

NEC 705.12 Check

### 100 A Required Backfeed OCPD

125% x 72.2 A = 90.2 A -> 100 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

### 415 V - 980 V (Max 980 V DC)

Tracking span of 565.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 60000.0W / 480 V 3-phase -> 72.2 A | Breaker >= 1.25 * 72.2 = 90.2 A -> 100 A

CEC Inverters.csv for SMA America: STPS60US-20 {480V}: Paco=60000.0 W, Vac=480 V, Vdcmax=980.0 V, Eff=97.57%.

**Result:** Min 100 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for SMA America: STPS60US-20 {480V}?

California Energy Commission Solar Equipment List parameters for SMA America: STPS60US-20 {480V} (grid-tied PV inverter) interconnection. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for SMA America: STPS60US-20 {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 60,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 980 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 415 V - 980 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 79.3484 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.57% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to SMA America: STPS60US-20 {480V} (480 V, 3-phase)?

Panelboard and switchgear backfeed allowances for SMA America: STPS60US-20 {480V} (100 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates SMA America: STPS60US-20 {480V} (100 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (480V)** | 80 A | 100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (480V)** | 120 A | 100 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (480V)** | 160 A | 100 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 100 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With SMA America: STPS60US-20 {480V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for SMA America: STPS60US-20 {480V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 415.0-980.0 V MPPT and 980.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 10 to 17 panels | 10.03 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 13 to 23 panels | 10.12 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 13 to 21 panels | 8.93 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 15 to 24 panels | 4.8 kW |

## Which Competing Grid-Support Inverters Compare to SMA America: STPS60US-20 {480V}?

Four alternative CEC inverters matched to SMA America: STPS60US-20 {480V} (60,000 W AC), led by ABB: TRIO-600-TL-OUTD-US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: TRIO-600-TL-OUTD-US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-trio-600-tl-outd-us-480-480v/) ABB | 60,000 W | Tie (0 W) | 480.0 V | 800.0 V | 98.18% |
| [**ABB: TRIO-TM-600-US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-trio-tm-600-us-480-480v/) ABB | 60,000 W | Tie (0 W) | 480.0 V | 800.0 V | 98.18% |
| [**Canadian Solar Inc: CSI-60KTL-CT {480V}**](https://epri-peac.com/solar-equipment/inverters/canadian-solar-inc/canadian-solar-inc-csi-60ktl-ct-480v/) Canadian Solar Inc | 60,000 W | Tie (0 W) | 480.0 V | 850.0 V | 98.24% |
| [**Canadian Solar Inc: CSI-60KTL-GS {480V}**](https://epri-peac.com/solar-equipment/inverters/canadian-solar-inc/canadian-solar-inc-csi-60ktl-gs-480v/) Canadian Solar Inc | 60,000 W | Tie (0 W) | 480.0 V | 720.0 V | 98.34% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: STPS60US-20 {480V}?

Check SMA America: STPS60US-20 {480V} (60,000 W AC, 100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 980 V DC on SMA America: STPS60US-20 {480V}.

### SMA America: STPS60US-20 {480V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 100 A OCPD breaker (72.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.57%) and MPPT window (415-980 V) directly against ABB: TRIO-600-TL-OUTD-US-480 {480V} (60,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: STPS60US-20 {480V} by SMA America covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does SMA America: STPS60US-20 {480V} require?

At 60,000 W continuous AC (480 V, 3-phase), continuous current is 72.2 A; 125% NEC 690.8/705.12 sizing requires a 100 A breaker and 3 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does SMA America: STPS60US-20 {480V} require?

At 60,000 W AC and 480 V, 3-phase, continuous line current is 72.2 A, requiring a 100 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does SMA America: STPS60US-20 {480V} compare to ABB: TRIO-600-TL-OUTD-US-480 {480V}?

SMA America: STPS60US-20 {480V} delivers 60,000 W AC at 97.57% CEC efficiency with a 980 V DC ceiling, while ABB: TRIO-600-TL-OUTD-US-480 {480V} outputs 60,000 W at 480 V, 3-phase.

## Related Pages

Explore SMA America hardware, ABB: TRIO-600-TL-OUTD-US-480 {480V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: STPS60US-20 {480V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4200 UP-US 630V 3850A {630V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)